Abstract
Nervous system injuries lead to loss of control of sensory, motor, and autonomic functions of the affected areas of the body. Provided the high amount of people worldwide suffering from these injuries and the impact on their everyday life, numerous and different neuroprostheses and hybrid bionic systems have been developed to restore or partially mimic the lost functions. A key point for usable neuroprostheses is the electrode that interfaces the nervous system and translates not only motor orders into electrical outputs that activate the prosthesis but is also able to transform sensory information detected by the machine into signals that are transmitted to the central nervous system. Nerve electrodes have been classified with regard to their invasiveness in extraneural, intraneural, and regenerative. The more invasive is the implant the more selectivity of interfacing can be reached. However, boosting invasiveness and selectivity may also heighten nerve damage. This chapter provides a general overview of nerve electrodes as well as the state-of-the-art of their biomedical applications in neuroprosthetic systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This marked a substantial improvement in selectivity in comparison to the cuff electrode, which indiscriminately interfaced the entire nerve bundle.23”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [23]
In the citing paper
“For penetrating arrays, the opposite is true: excellent integration with individual nerve fibers comes at the expense of a poorer tissue response due to the trauma and inflammation resulting from device implantation.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [23]
In the citing paper
“As the cuff electrode wraps around the exterior of the nerve, it offers reasonable biocompatibility at the expense of selectivity in recording compound signals and stimulation of nerve fascicles.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [23]
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Self-citationSpecificity of peripheral nerve regeneration: Interactions at the axon level
Allodi, I., Udina, E., & Navarro, X. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.05.005 · Cited by 420
Self-citationFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Kuiken, T. A., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 283
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Self-citationLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Self-citationThe effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
The application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
EMG pattern recognition based on artificial intelligence techniques
Park, S.-H., & Lee, S.-P. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736154 · Cited by 197
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194
An Implanted Upper-Extremity Neuroprosthesis Using Myoelectric Control
Kilgore, K. L., Hoyen, H. A., Bryden, A. M., Hart, R. L., Keith, M. W., & Peckham, P. H. (2008) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2008.01.007 · Cited by 189
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Dhillon, G. S., Krüger, T. B., Sandhu, J. S., & Horch, K. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00937.2004 · Cited by 183
Lago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Self-citationMyoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156
Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144
Functional electrical stimulation for grasping and walking: indications and limitations
Popović, M. R., Curt, A. E. P., Keller, T., & Dietz, V. (2001) · Spinal Cord · doi:10.1038/sj.sc.3101191 · Cited by 139
Implantable electrical and mechanical interfaces with nerve and muscle
Hoffer, J. A., & Loeb, G. E. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363438 · Cited by 131
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Self-citationAn implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up
Guiraud, D., Stieglitz, T., Koch, K. P., Divoux, J.-L., & Rabischong, P. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/003 · Cited by 117
Zhang, D., Peng, Y., Qi, H., Gao, Q., & Zhang, C. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.010 · Cited by 115
Tarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
(1998) · PubMed · Cited by 107
Self-citationLawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106
Modular transcutaneous functional electrical stimulation system
Popović, M. R., & Keller, T. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.08.016 · Cited by 104
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103
Self-citationMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
Self-citationSubfascicle stimulation selectivity with the flat interface nerve electrode
Leventhal, D. K., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569266 · Cited by 81
Raspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Self-citation(1996) · PubMed · Cited by 79
Hand Transplantation: The State-of-the-Art
Schuind, F. A., Abramowicz, D., & Schneeberger, S. (2006) · Journal of Hand Surgery (European Volume) · doi:10.1016/j.jhsb.2006.09.008 · Cited by 78
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes
Yoshida, K., & Stein, R. B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740885 · Cited by 76
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091149 · Cited by 72
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Self-citationDelivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68
Lago, N., Udina, E., Ramachandran, A., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891168 · Cited by 68
Self-citationBioartificial Nerve Grafts:A prototype
Lundborg, G., & Kanje, M. (1996) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844319609056391 · Cited by 64
Castro, J., Negredo, P., & Avendaño, C. (2008) · Brain Research · doi:10.1016/j.brainres.2007.11.028 · Cited by 63
Effect of sacral anterior root stimulator on bowel dysfunction in patients with spinal cord injury
Vallès, M., Rodríguez, A., Borau, A., & Mearin, F. (2009) · Diseases of the Colon & Rectum · doi:10.1007/dcr.0b013e31819ed459 · Cited by 56
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56
(2001) · PubMed · Cited by 52
Self-citationReanimating limbs after injury or disease
Stein, R. B., & Mushahwar, V. K. (2005) · Trends in Neurosciences · doi:10.1016/j.tins.2005.07.007 · Cited by 48
Interfacing the body’s own sensing receptors into neural prosthesis devices
Haugland, M., & Sinkjær, T. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7603 · Cited by 46
Peripheral nerve regeneration through microelectrode arrays based on silicon technology
Navarro, X., Calvet, S., Butí, M., Gómez, N., Cabruja, E., Garrido, P., Villa, R., & Valderrama, E. (1996) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-1996-9303 · Cited by 46
Self-citationRegenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46
Sacral Nerve Stimulation: Neuromodulation for Voiding Dysfunction and Pain
Mayer, R., & Howard, F. M. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.063 · Cited by 45
Modality-Specific Axonal Regeneration: Toward Selective Regenerative Neural Interfaces
Lotfi, P., Garde, K., Chouhan, A. K., Bengali, E., & Romero-Ortega, M. I. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00011 · Cited by 42
Functional electrical stimulation for bladder, bowel, and sexual function
Creasey, G. H., & Craggs, M. D. (2012) · Handbook of clinical neurology · doi:10.1016/b978-0-444-52137-8.00015-2 · Cited by 42
Functional Electrical Stimulation in Spinal Cord Injury Respiratory Care
Jarosz, R., Littlepage, M., Creasey, G. H., & McKenna, S. L. (2012) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1804-315 · Cited by 42
Inmann, A., & Haugland, M. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.003 · Cited by 40
Nogan Bailey, S., Hardin, E. C., Kobetic, R., Boggs, L. M., Pinault, G., & Triolo, R. J. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.03.0034 · Cited by 39
Sensinger, J. W., Schultz, A. E., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032640 · Cited by 39
Grill, W. M., McDonald, J. W., Peckham, P. H., Heetderks, W., Kocsis, J. D., & Weinrich, M. (2001) · PubMed · Cited by 39
Navarro, X., Lago, N., Vivo, M., Yoshida, K., Koch, K. P., Poppendieck, W., & Micera, S. (2007) · 2007 IEEE 10th International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428492 · Cited by 36
Self-citationGraupe, D., Bazo, H. A. C., Kern, H., & Carraro, U. (2008) · Neurological Research · doi:10.1179/174313208x281136 · Cited by 36
Dutta, A., Kobetic, R., & Triolo, R. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3086356 · Cited by 36
Rupp, R., & Gerner, H. J. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.019 · Cited by 31
Shape Memory Alloy Microactuation of tf-LIFEs: Preliminary Results
Bossi, S., Menciassi, A., Koch, K. P., Hoffmann, K.-P., Yoshida, K., Dario, P., & Micera, S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895186 · Cited by 29
Preliminary experiments in nerve regeneration through laser-drilled holes in silicon chips
Rosen, J. M., Grosser, M., & Hentz, V. R. (1990) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-1990-2205 · Cited by 25
THE INTRINSIC HAND – A 22 DEGREE-OF-FREEDOM ARTIFICIAL HAND-WRIST REPLACEMENT
Weir, R. F. F., Mitchell, M., Clark, S. L., Puchhammer, G., Haslinger, M. J., Grausenburger, R., Kumar, N., Hofbauer, R., Kuschnigg, P., Cornelius, V., et al. (2008) · DukeSpace (Duke University) · Cited by 24
Kottink, A. I. R., Buschman, H. P. J., Kenney, L. P. J., Veltink, P. H., Slycke, P. J., Bultstra, G., & Hermens, H. J. (2004) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1094-7159.2004.04213.x · Cited by 24
Modelization of a self-opening peripheral neural interface: A feasibility study
Cutrone, A., Sergi, P. N., Bossi, S., & Micera, S. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.06.001 · Cited by 22
Panetsos, F., Avendano, C., Negredo, P., Castro, J., & Bonacasa, V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.923707 · Cited by 20
Neural prostheses in clinical practice: biomedical microsystems in neurological rehabilitation
Stieglitz, T. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_54 · Cited by 20
Toward a Convergence of Regenerative Medicine, Rehabilitation, and Neuroprosthetics
Aravamudhan, S., & Bellamkonda, R. V. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1542 · Cited by 19
Bifurcating microchannels as a scaffold to induce separation of regenerating neurites
Wieringa, P. A., Wiertz, R. W. F., de Weerd, E., & Rutten, W. L. C. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016001 · Cited by 18
Walter, Griffith, P., Sweeney, J., Scarpine, V., Bidnar, M., McLane, J., & Robinson, C. (1997) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.1997.11719475 · Cited by 18
Blind source separation of neural recordings and control signals
Tesfayesus, W., & Durand, D. M. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260400 · Cited by 12
Andrews, R. J. (2009) · Progress in brain research · doi:10.1016/s0079-6123(08)80007-6 · Cited by 11
A sieve electrode as a potential autonomic neural interface for bionic medicine
Kawada, T., Zheng, C., Tanabe, S., Uemura, T., Sunagawa, K., & Sugimachi, M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404202 · Cited by 11
Recording with microchannel electrodes in a noisy environment
FitzGerald, J. J., Lacour, S. P., & Fawcett, J. W. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649084 · Cited by 10
THE INTRINSIC HAND - A 22 DEGREE-OF-FREEDOM ARTIFICIAL HAND-WRIST REPLACEMENT
Bock, O. (2008) · Cited by 9
Cited by
A wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514
“1b [7-9]).”
Identification of cytokine-specific sensory neural signals by decoding murine vagus nerve activity
Zanos, T. P., Silverman, H. A., Levy, T., Tsaava, T., Battinelli, E., Lorraine, P. W., Ashe, J. M., Chavan, S. S., Tracey, K. J., & Bouton, C. E. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719083115 · Cited by 201
A review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Self-citationSemiconducting Polymers for Neural Applications
Dimov, I. B., Moser, M., Malliaras, G. G., & McCulloch, I. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00685 · Cited by 158
Metadata
- Authors
- del Valle, J., & Navarro, X.
- Affiliations
- Universitat Autònoma de Barcelona (ES)
- Corresponding author
- Navarro, Xavier
- ORCID
- Navarro, Xavier
- Venue
- International Review of Neurobiology
- Publisher
- Elsevier
- Published
- 2013
- Volume
- 109
- Pages
- 63-83
- ISSN
- 0074-7742 (ISSN-L)
- OpenAlex
- W2408439898
- Cited by
- 105
- References
- 104
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 10 · 2023: 10 · 2022: 10 · 2021: 9 · 2020: 7 · 2019: 14 · 2018: 9 · 2017: 10 · 2016: 6 · 2015: 7 · 2014: 2 · 2013: 1
- FWCI
- 8.78
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- International review of neurobiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- neural prostheses, peripheral nerve interfaces, nervous system injury, sensory feedback, motor control, nerve injury, functional restoration
- MeSH terms
- Animals, Bionics, Electrodes, Implanted, Humans, Peripheral Nerves, Prostheses and Implants, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.