Sweat sensing in the smart wearables era: Towards integrative, multifunctional and body-compliant perspiration analysis
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
All life forms use a seamless integration of physical and chemical sensing mechanisms to enhance their performance and survival skills. To mimic the integrative sensing abilities found in nature, there is a significant interest in developing wearable devices that can smartly track the physiological and biochemical signals of the human body. Progress in wearable physical sensors has been remarkable giving rise to a number of consumer electronics products meant to measure parameters related to activity, posture, heart rate, respiration rate, and blood oxygen level. Comparatively, the progress in wearable chemical sensor development has been slower because of the inherent challenges in retrieving and processing bodily fluids. In this context, sweat provides a rich repository of biomarkers that is accessible continuously, on-the-go, and non-invasively. Here we provide a review of recent trends in the area of wearable sweat sensing with discussions on relevant topics of interest in material science, device development, sensing mechanisms, power generation, and data management. Exemplary wearable sweat sensors published in recent years are provided along with commercialization efforts in wearable sweat sensing. The review highlights the trends in multifunctional sensing platforms with flexible electronics that integrate data from both physical and biochemical sweat sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 1×
“For wearable sweat sensng applications, PVB-based reference electrodes are widely used ecause of their high stability in generating the interfacial potential, long with the ease of fabrication and compatibility with printing echniques [97,98].”
MethodWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · cited 2×
“parylene, polypyrrole, polydimethylsiloxane (PDMS), polyethylene naphthalate (PEN), and polyethylene terephthalate (PET), or Kapton) [35,66,67,88,89].”
BackgroundBariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · cited 5×
“diabetes, hypocalcemia, liver, r renal diseases) — thus obviating the need for painful blood samling [4,7,8].”
BackgroundInfluentialWearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · cited 5×
“Increased presence of lactate in sweat has been associated in shift from aerobic to anaerobic metabolic conditions and is often roduced during exercise [9,11,59,60].”
BackgroundInfluentialLee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Diagnosis of Cystic Fibrosis: Consensus Guidelines from the Cystic Fibrosis Foundation
Farrell, P. M., White, T. B., Ren, C. L., Hempstead, S. E., Accurso, F., Derichs, N., Howenstine, M., McColley, S. A., Rock, M., Rosenfeld, M., et al. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.09.064 · Cited by 953
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · cited 2×
“As a limitation, it is unclear whether wearable sensors integrated with textiles can withstand multiple rounds of washing and drying without compromising their performance [12,13].”
BackgroundSonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Highly efficient and bending durable perovskite solar cells: toward a wearable power source
Kim, B. J., Kim, D. H., Lee, Y.-Y., Shin, H.-W., Han, G. S., Hong, J. S., Mahmood, K., Ahn, T. K., Joo, Y.-C., Hong, K. S., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee02441a · Cited by 679
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475 · cited 3×
“Near-skin sweat sensors constantly wick the produced sweat nd transport it through fluidic channels to the electrodes; thereby voiding issues of sweat pooling and contamination [62,102,103].”
BackgroundA wearable multisensing patch for continuous sweat monitoring
Anastasova, S., Crewther, B., Bembnowicz, P., Curto, V., Ip, H. M., Rosa, B., & Yang, G.-Z. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.038 · Cited by 443 · cited 1×
“Flexible electrodes for sweat sensors are generally fabricated by screen-printing and photolithography, even though other methods have been explored such as dip-coating, sputtering, and e-beam evaporation [45,66,90,94,95].”
BackgroundVariations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433 · cited 3×
“Sweat provides the possibility of non-invasive, continuous, and omfortable sample collection [14,15].”
BackgroundTierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387 · cited 2×
“The sweat produced by eccrine glands is particularly relevant to earable sweat sensors [18,53].”
BackgroundTattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367 · cited 1×
“As such, significant interest has hifted in developing technologies to accurately monitor and charcterize changes in saliva [11,27,28], tears [11,26,29–32], sweat 2,7,11,14,16,18,20,25,33–48], and interstitial fluid [4,23,40,49].”
BackgroundChoi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343 · cited 3×
“Sodium and chloride levels are also ndicators of dehydration during the physical activities of athetes [9,51], while ammonium levels are related to extreme fatigue onditions [9,33].”
BackgroundStretchable wireless system for sweat pH monitoring
Dang, W., Manjakkal, L., Navaraj, W. T., Lorenzelli, L., Vinciguerra, V., & Dahiya, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.025 · Cited by 326 · cited 5×
“Medical diagnostic tools are being adapted to acilitate non-invasive and low-cost testing in the convenience of home setting [2].”
BackgroundMethodInfluentialEpidermal Biofuel Cells: Energy Harvesting from Human Perspiration
Jia, W., Valdés‐Ramírez, G., Bandodkar, A. J., Windmiller, J. R., & Wang, J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201302922 · Cited by 324
Eyeglasses based wireless electrolyte and metabolite sensor platform
Sempionatto, J. R., Nakagawa, T., Pavinatto, A., Mensah, S. T., Imani, S., Mercier, P., & Wang, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00192d · Cited by 311
Methylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310 · cited 1×
“Sweatbands have also been integrated with iontophoresis systems to actively stimulate the sweat glands and extract the sweat sample [46,61].”
BackgroundComposition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294 · cited 1×
“(ii) Apocrine sweat glands re located within hair follicles and are innervated by nerves of the drenergic pathways [53,54].”
BackgroundA wearable electrochemical sensor for the real-time measurement of sweat sodium concentration
Schazmann, B., Morris, D., Slater, C., Beirne, S., Fay, C., Reuveny, R., Moyna, N., & Diamond, D. (2010) · Analytical Methods · doi:10.1039/b9ay00184k · Cited by 286 · cited 1×
“Sodium Dehydration, Cystic fibrosis [2,16,21,38,43,44,45,57,58,65]”
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229 · cited 5×
“Blood glucose is a critical parameter to monior blood sugar imbalances in diabetes (such as hypoglycemia and yperglycemia) and has been measured by sweat analysis [5].”
BackgroundInfluentialA contact lens with an integrated lactate sensor
Thomas, N., Lähdesmäki, I., & Parviz, B. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.12.049 · Cited by 220
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075007 · Cited by 182
A wearable patch for continuous monitoring of sweat electrolytes during exertion
Alizadeh, A., Burns, A., Lenigk, R., Gettings, R., Ashe, J., Porter, A., McCaul, M., Barrett, R., Diamond, D., White, P., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00510a · Cited by 180 · cited 1×
“Among these, PEDOT:PSS is the most widely studied conducting polymer as an ion-to-electron transducer for sweat analytes as it has very good stability and sensitivity characteristics [87,92,93].”
BackgroundSweat composition in exercise and in heat
Verde, T., Shephard, R. J., Corey, P., & Moore, R. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1540 · Cited by 174
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156 · cited 2×
“5 min) from the blood alcohol level which can be attributed o the complex partitioning of ethanol in human tissues [74].”
BackgroundA Flexible and Wearable Human Stress Monitoring Patch
Yoon, S., Sim, J. K., & Cho, Y.-H. (2016) · Scientific Reports · doi:10.1038/srep23468 · Cited by 151
Wearable electrochemical alcohol biosensors
Campbell, A. S., Kim, J., & Wang, J. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.014 · Cited by 140 · cited 3×
“In addition, sweat s a means by which the body tries to excrete toxic chemicals (heavy etals [16], alcohol [9,25,39,40], urea and creatinine [36,37,64]).”
BackgroundEccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86 · cited 1×
“range of concentrations reported for different sweat analytes [16,38,41,42,50].”
BackgroundIron, copper and zinc concentrations in human sweat and plasma; the effect of exercise
Aruoma, O. I., Reilly, T., MacLaren, D., & Halliwell, B. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90310-5 · Cited by 83
Cited by
Wearable and flexible electrochemical sensors for sweat analysis: a review
Gao, F., Liu, C., Zhang, L., Liu, T., Wang, Z., Song, Z., Cai, H., Fang, Z., Chen, J., Wang, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00443-6 · Cited by 764
Patel, V., Chesmore, A., Legner, C. M., & Pandey, S. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100099 · Cited by 336
Self-citationPrintable Smart Materials and Devices: Strategies and Applications
Su, M., & Song, Y. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00303 · Cited by 312
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Metadata
- Authors
- Legner, C., Kalwa, U., Patel, V., Chesmore, A., & Pandey, S.
- Venue
- Sensors and Actuators A: Physical
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 296
- Pages
- 200-221
- ISSN
- 0924-4247 (ISSN-L)
- OpenAlex
- W2961654883
- Cited by
- 142
- References
- 49
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.