Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index; 11 of the 65 sources its claims cite were checked for support.
Abstract
Proposed 3D neural electrode can self-climb onto peripheral nerve driven by body temperature and form flexible neural interface.
Overview
CoChat Summary
TL;DR
The paper presents a climbing-inspired twining electrode made of a shape memory polymer substrate and mesh serpentine Au/Ti/PI wires that self-climbs onto peripheral nerves when actuated by body temperature (~37°C), forming a conformal interface without additional surgical fixation. In rabbits, the device was used for vagus nerve stimulation with ECG recording and for sciatic nerve evoked action potential recording.
Key findings
- The synthesized SMP has a transition temperature of ~37°C, shape fixity and recovery ratios above 97% over four cycles, fracture strain ~1100%, and elastic modulus changing from ~100 MPa to ~300 kPa before and after the phase transition.
- Electrochemical characterization showed average CDC ~9.7 mC/cm² and impedance magnitude ~156 ohms at 1 kHz, with little change across initial flat, reconfigured, flattened, and recovery states; fabricated electrodes had ~126 ohms at ~0.5 mm inner radius and ~119 ohms at ~1 mm inner radius.
- Structural optimization gave r0/r = 0.98 and maximum Au strain εAumax = 0.24%; the twining electrode had bending stiffness EI ~1.0 × 10⁻¹⁰ N·m² and stretching stiffness EA 0.08 N, and FEA showed Au strain below fracture strain (5%) during 20% swelling and below yield strain (0.3%) during 20% stretching and bending (R = 15 mm).
- In vivo, epinephrine increased rabbit heart rate from 180 to 240 bpm; VNS at 0.4 mA, 100 μs, 10 Hz reduced HR to 180 bpm and increased R-wave peak from 100 to 250 mV. Sciatic nerve recording showed evoked CNAP peak potentials of ~275, ~380, and ~820 μV for 0.1, 0.15, and 0.3 mA stimulation, and ~80 μV evoked CNAPs without stimulus artifact at an SNR of 16 dB.
Methods
- The electrode was fabricated by depositing/etching Au/Ti mesh serpentine structures on ultrathin PI, transfer printing them onto an SMP substrate, reconfiguring the assembly into a 3D helix at 180°C for 10 min, and temporarily flattening it at 37°C; self-climbing was driven by 37°C normal saline.
- Material and device characterization included DSC, DMA, tensile testing, CV, and EIS in phosphate-buffered saline using a three-electrode setup with six samples in four states; FEA (Abaqus) modeled stress/strain under 20% swelling, 20% stretching, and bending to R = 15 mm.
- In vivo experiments used two New Zealand rabbits (3.2–3.3 kg): one for right vagus nerve stimulation with ECG recording, and one for sciatic nerve evoked potential recording using hooked platinum stimulating electrodes and twining recording electrodes.
Limitations
- The paper does not include a dedicated limitations section; it states that future twining electrodes will benefit from new high-surface-area materials and high-resolution designs for selective stimulation and recording.
- Evident from the text: in vivo validation was acute and limited to two rabbits, with no chronic implantation, long-term stability, or histological safety data reported.
- Evident from the text: biocompatibility of the main SMP precursors is cited from previous work rather than newly demonstrated in this study.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
6 Valid · 2 Not valid · 17 Not checked · 62 Own results and interpretations
None of the sources cited for this claim have been checked yet.
In the paper
“Large mechanical and geometrical mismatches still exist at the neural interfaces.”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > INTRODUCTION
What the sources say
- Not checked yetcites [5] Naples R. G., Mortimer J. T., Scheiner A., Sweeney J. D., A spiral nerve cuff electrode for peripheral nerve stimulation. IEEE Trans. Biomed. Eng. 35, 905– 916 (1988). 3198136 source
- Not checked yetcites [6] Tarver W. B., George R. E., Maschino S. E., Holder L. K., Wernicke J. F., Clinical experience with a helical bipolar stimulating lead. Pacing Clin. Electrophysiol. 15, 1545– 1556 (1992). 1383969 source
- Not checked yetcites [7] Tyler D. J., Durand D. M., Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans. Neural Syst. Rehabil. Eng. 10, 294– 303 (2002). 12611367 source
- Could not verifycites [8] Foldes E. L., Ackermann D. M., Bhadra N., Kilgore K. L., Bhadra N., Design, fabrication and evaluation of a conforming circumpolar peripheral nerve cuff electrode for acute experimental use. J. Neurosci. Methods 196, 31– 37 (2011). 21187115 PMC3042051 sourceExperimental — accuracy not yet measured
Our copy of Foldes et al. (2011) frames the electrode-nerve interface in terms of achieving a conforming, close-fitting geometry — the Introduction stresses that 'consistent and predictable electrical peripheral nerve stimulation requires a robust and stable physical interface' obtained by a cylindrical cuff conforming to the nerve, and §2.1 sets a cuff-to-nerve diameter ratio of 0.9–1.1 — but it nowhere asserts that large mechanical or geometrical mismatches persist at neural interfaces, and it makes no statement about mechanical/compliance (stiffness) mismatch or about 'first-generation extraneural electrodes'. The Discussion (§4) notes only minor geometric limits of its own design (silicone bowing at IPDs beyond ~4 mm, sheath opening at lengths >2 mm), which is not the general claim being attributed. Searches run: 'mechanical and geometrical mismatch at the neural interface', 'compliance mismatch between electrode and nerve tissue', 'limitations of existing cuff electrodes: size mismatch, stiffness, poor conformal contact', 'first generation extraneural electrode problems'. Nothing in our copy supports or contradicts the claim, so it cannot be judged from this source. (LLM, conf=0.62)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“To decrease damage to nerves and increase long-term stability, several forms of extraneural electrodes have been proposed to replace intraneural electrodes, which penetrate into the nerve fascicles (3, 4).”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > INTRODUCTION
What the sources say
- Could not verifycites [3] Fattahi P., Yang G., Kim G., Abidian M. R., A review of organic and inorganic biomaterials for neural interfaces. Adv. Mater. 26, 1846– 1885 (2014). 24677434 PMC4373558 sourceExperimental — accuracy not yet measured
Our copy of Fattahi et al. (2014) never addresses extraneural versus intraneural (intrafascicular) electrodes for peripheral nerves; searched for 'extraneural', 'intrafascicular/nerve fascicles', 'cuff/peripheral nerve electrodes' and 'penetrating vs surface electrodes to reduce damage and improve long-term stability'. The closest passages discuss central implants only — e.g., Section 6.3 (Mechanical Stability) that stiff silicon penetrating electrodes 'create mechanical trauma on insertion' while flexible polyimide/parylene 'may improve this issue', and Section 3.1 that flexible surface microelectrodes 'may generate less tissue damage and be functional longer than silicon-based electrodes' — plus Section 6.3 mentioning hydrogel tubes 'for interfacing with the peripheral nerve'. None of these states the proposal of extraneural electrodes to replace fascicle-penetrating ones, so the claim can be neither confirmed nor contradicted from our copy. (LLM, conf=0.70)
- Partly supportedcites [4] Ecker M., Joshi-Imre A., Modi R., Frewin C. L., Garcia-Sandoval A., Maeng J., Gutierrez-Heredia G., Pancrazio J. J., Voit W. E., From softening polymers to multimaterial based bioelectronic devices. Multifunct. Mater. 2, 012001 (2019). sourceExperimental — accuracy not yet measured
Our copy supports the extraneural half of the claim: §2.2 (Nerve cuffs) describes 'several forms' of cuffs wrapping around nerves — first-generation hook-like self-coiling devices [30], newer folding thin-film cuffs in various sizes for acute and chronic studies [68,73], and softening-polymer cuffs — and the Fig. 3 caption explicitly labels them 'extra-neural cuff' devices; §2.2 also ties these to reducing nerve damage ('often causes nerve damage [67,68]', 'safer electrical stimulation') and to chronic/long-term use. What our copy does NOT support is the replacement framing: no passage mentions intraneural/intrafascicular electrodes or devices that penetrate nerve fascicles, and the paper's stated motive is overcoming the limits of silicone cuff electrodes (thickness, hardness, no size adjustment), not supplanting intraneural ones. The 'increase long-term stability' rationale appears only generally (§5.2 on reliability of chronic implants), not as a comparison against intraneural electrodes. (LLM, conf=0.68)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“With the introduction of dynamic covalent bonds into the polymer network, the permanent shape of traditional thermoset SMPs can be reconfigured (23, 24).”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > INTRODUCTION
What the sources say
- Supportedcites [23] Zhao Q., Zou W., Luo Y., Xie T., Shape memory polymer network with thermally distinct elasticity and plasticity. Sci. Adv. 2, e1501297 (2016). 26824077 PMC4730863 source
The Introduction (Abstract section) states that permanent reshaping without macroscopic melting 'is achieved by covalent bond exchange in a polymer network, allowing its topography to be rearranged in response to an external force... the permanent reshaping can occur while the material maintains its dynamic crosslinking state,' listing 'malleability of thermoset polymers' among its consequences. The paper's own crosslinked PCL-thiolene network (Fig. 1A right-hand route; Figs. 3-4 discussion) demonstrates exactly this: reversible covalent bonds activated at Tp give nonrecoverable, cumulative redefinition of a permanently crosslinked (thermoset) SMP's permanent shape, with 'numerous cycles of manipulation of a permanent shape.' The paraphrase therefore matches what this source attributes. (LLM, conf=0.85)
- Not checked yetcites [24] Zheng N., Hou J., Xu Y., Fang Z., Zou W., Zhao Q., Xie T., Catalyst-free thermoset polyurethane with permanent shape reconfigurability and highly tunable triple-shape memory performance. ACS Macro Lett. 6, 326– 330 (2017). 35610855 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The differential scanning calorimeter (DSC) curve for the synthetic SMPs (Fig. 3A) shows that the melt transition temperature (Tm) is approximately 37°C (i.e., Ttrans = ~37°C), which means that the SMPs recovering their permanent shapes can be actuated by body temperature (movie S4).”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > RESULTS > Material characterization and structure optimization
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Distinct elastic modulus controllability from ~100 MPa to ~300 kPa before and after the phase transition greatly facilitates the surgical implantation in limited space, where the twining electrodes are handled in a relatively stiff state and soften after climbing on the nerves.”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > INTRODUCTION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
38 more claims
Create a free account to see all 87 claims and to verify the 54 references still open.
- Probably not a substantial claim. 17
- It may state two separate claims as one. 29
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In vivo Vagus nerve stimulation was carried out on a rabbit to demonstrate the validity of the device (Figure 8F).”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [358]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > RESULTS > Material characterization and structure optimization
“the selected hSMP and hPI are ~2 and ~100 μm, respectively”
§ Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording > RESULTS > Fabrication process
“Fabrication of the mesh serpentine starts with spin casting of an ultrathin PI film (~2 μm) (fig. S3) onto silicon wafers coated with a layer of a sacrificial polymethylmethacrylate (PMMA) film.”
Citations
Cites
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Fractal design concepts for stretchable electronics
Fan, J. A., Yeo, W.-H., Su, Y., Hattori, Y., Lee, W., Jung, S.-Y., Zhang, Y., Liu, Z., Cheng, H., Falgout, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms4266 · Cited by 1,088
Self-citation3D Printing of Shape Memory Polymers for Flexible Electronic Devices
Zarek, M., Layani, M., Cooperstein, I., Sachyani, E., Cohn, D., & Magdassi, S. (2016) · Advanced Materials · doi:10.1002/adma.201503132 · Cited by 903
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Highly Flexible Silver Nanowire Electrodes for Shape‐Memory Polymer Light‐Emitting Diodes
Yu, Z., Zhang, Q., Li, L., Chen, Q., Niu, X., Liu, J., & Pei, Q. (2011) · Advanced Materials · doi:10.1002/adma.201003398 · Cited by 688
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · cited 1×
“To decrease damage to nerves and increase long-term stability, several forms of extraneural electrodes have been proposed to replace intraneural electrodes, which penetrate into the nerve fascicles (3, 4).”
BackgroundA jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Flexible and Stretchable Electronics Paving the Way for Soft Robotics
Lu, N., & Kim, D.-H. (2014) · Soft Robotics · doi:10.1089/soro.2013.0005 · Cited by 535
Chronic vagus nerve stimulation: A new and promising therapeutic approach for chronic heart failure
De Ferrari, G. M., Crijns, H. J. G. M., Borggrefe, M., Milasinovic, G., Smid, J., Zabel, M., Gavazzi, A., Sanzo, A., Dennert, R., Kuschyk, J., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq391 · Cited by 523
Shape memory polymer network with thermally distinct elasticity and plasticity
Zhao, Q., Zou, W., Luo, Y., & Xie, T. (2016) · Science Advances · doi:10.1126/sciadv.1501297 · Cited by 514
Self-citationHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501 · cited 1×
“6 × 10 N·m(2), respectively (5, 8, 9, 43), while the EI value of the twining electrodes is ~1.”
BackgroundImplanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Competing Fracture in Kinetically Controlled Transfer Printing
Feng, X., Meitl, M. A., Bowen, A. M., Huang, Y., Nuzzo, R. G., & Rogers, J. A. (2007) · Langmuir · doi:10.1021/la701555n · Cited by 411
Self-citationDesign of metal interconnects for stretchable electronic circuits
Gonzalez, M., Axisa, F., Bulcke, M. V., Brosteaux, D., Vandevelde, B., & Vanfleteren, J. (2008) · Microelectronics Reliability · doi:10.1016/j.microrel.2008.03.025 · Cited by 405
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Premchand, R. K., Sharma, K., Mittal, S., Monteiro, R., Dixit, S., Libbus, I., DiCarlo, L. A., Ardell, J. L., Rector, T. S., Amurthur, B., et al. (2014) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2014.08.009 · Cited by 377
Zhang, Y., Wang, S., Li, X., Fan, J. A., Xu, S., Song, Y. M., Choi, K., Yeo, W., Lee, W., Nazaar, S. N., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201302957 · Cited by 354
Self-citationMoving with climbing plants from Charles Darwin’s time into the 21st century
Isnard, S., & Silk, W. K. (2009) · American Journal of Botany · doi:10.3732/ajb.0900045 · Cited by 331
Lundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316
Mechanical properties of acellular peripheral nerve
Borschel, G. H., Kia, K. F., Kuzon, W. M., & Dennis, R. G. (2003) · Journal of Surgical Research · doi:10.1016/s0022-4804(03)00255-5 · Cited by 284
On the Movements and Habits of Climbing Plants
Darwin, C. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511703010 · Cited by 282
On the Movements and Habits of Climbing Plants.
Darwin, C. (1865) · Journal of the Linnean Society of London, Botany · doi:10.1111/j.1095-8339.1865.tb00011.x · Cited by 263
Zheng, N., Hou, J., Xu, Y., Fang, Z., Zou, W., Zhao, Q., & Xie, T. (2017) · ACS Macro Letters · doi:10.1021/acsmacrolett.7b00037 · Cited by 237
Self-citationStretchability and compliance of freestanding serpentine-shaped ribbons
Widlund, T., Yang, S., Hsu, Y.-Y., & Lu, N. (2014) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2014.07.025 · Cited by 197
Barrioni, B. R., de Carvalho, S. M., Oréfice, R. L., de Oliveira, A. A. R., & Pereira, M. D. M. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.03.027 · Cited by 189
Vagus nerve stimulation: From pre-clinical to clinical application: Challenges and future directions
De Ferrari, G. M., & Schwartz, P. J. (2011) · Heart Failure Reviews · doi:10.1007/s10741-010-9216-0 · Cited by 169
The movements and habits of climbing plants
Darwin, C. (1888) · D. Appleton eBooks · doi:10.5962/bhl.title.2110 · Cited by 162
Synthesis of two-component injectable polyurethanes for bone tissue engineering
Bonzani, I. C., Adhikari, R., Houshyar, S., Mayadunne, R., Gunatillake, P., & Stevens, M. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.026 · Cited by 159 · cited 1×
“In addition, the biocompatibility of the main precursors in our SMPs has been previously demonstrated (38, 39).”
MethodSelf-Peeling Reversible Dry Adhesive System
Xie, T., & Xiao, X. (2008) · Chemistry of Materials · doi:10.1021/cm800173c · Cited by 144
Self-citationWare, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138
Xiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116 · cited 2×
“Next, according to previous studies (9, 49, 51), electrical stimulation with a constant current amplitude of 0.”
BackgroundResultThin film multi-electrode softening cuffs for selective neuromodulation
González-González, M. A., Kanneganti, A., Joshi-Imre, A., Hernandez-Reynoso, A. G., Bendale, G., Modi, R., Ecker, M., Khurram, A., Cogan, S. F., Voit, W. E., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-34566-6 · Cited by 97
Larsen, J. O., Thomsen, M., Haugland, M., & Sinkjær, T. (1998) · Acta Neuropathologica · doi:10.1007/s004010050907 · Cited by 96
Review on flexible photonics/electronics integrated devices and fabrication strategy
Cai, S., Han, Z., Wang, F., Zheng, K., Cao, Y. K., Ma, Y., & Feng, X. (2018) · Science China Information Sciences · doi:10.1007/s11432-018-9442-3 · Cited by 94
Self-citationFlexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86
Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78
Selective stimulation and neural recording on peripheral nerves using flexible split ring electrodes
Lee, S., Sheshadri, S., Xiang, Z., Delgado-Martinez, I., Xue, N., Sun, T., Thakor, N. V., Yen, S.-C., & Lee, C. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.09.127 · Cited by 73
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69
Brack, K. E., Coote, J. H., & Ng, G. A. (2003) · Experimental Physiology · doi:10.1113/expphysiol.2003.002654 · Cited by 67 · cited 1×
“Next, according to previous studies (9, 49, 51), electrical stimulation with a constant current amplitude of 0.”
ResultChanges in nerve microcirculation following peripheral nerve compression.
Gao, Y., Weng, C., & Wang, X. (2013) · PubMed Central · doi:10.3969/j.issn.1673-5374.2013.11.010 · Cited by 67
Foldes, E. L., Ackermann, D. M., Bhadra, N., Kilgore, K. L., & Bhadra, N. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.12.020 · Cited by 61 · cited 1×
“6 × 10 N·m(2), respectively (5, 8, 9, 43), while the EI value of the twining electrodes is ~1.”
BackgroundWeremfo, A., Carter, P., Hibbert, D. B., & Zhao, C. (2015) · Langmuir · doi:10.1021/la504876n · Cited by 59 · cited 3×
“A larger CDC can decrease the current amplitudes that are required to activate the nerves during the stimulation, which can also decrease the electrical damage to the nerve (10, 40, 41).”
BackgroundMethodLee, Y. J., Kim, H.-J., Do, S. H., Kang, J. Y., & Lee, S. H. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.06.169 · Cited by 54
Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., et al. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.006 · Cited by 48
Clinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
Mathews, K. S., Wark, H. A. C., & Normann, R. A. (2014) · Muscle & Nerve · doi:10.1002/mus.24171 · Cited by 26
A finite deformation theory for the climbing habits and attachment of twining plants
Zhang, Y., Wu, J. C., Ma, Y., Chen, H., Ying, C., Lu, B., & Feng, X. (2018) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2018.03.021 · Cited by 24
Self-citationComplete removal of vagus nerve stimulator generator and electrodes: Technical note
Ortler, M., Unterhofer, C., Dobesberger, J., Haberlandt, E., & Trinka, E. (2010) · Journal of Neurosurgery: Pediatrics · doi:10.3171/2009.9.peds0810 · Cited by 22 · cited 1×
“Several adverse reactions caused by these drawbacks have been reported clinically, such as vomiting, cough, and difficulty in breathing in VNS therapy (18, 19).”
BackgroundFlexible 3D carbon nanotubes cuff electrodes as a peripheral nerve interface
Tian, P. W., Yi, W., Chen, C., Hu, J., Qi, J., Zhang, B., & Cheng, M. M. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0268-6 · Cited by 17 · cited 2×
“Therefore, much effort has been devoted to decreasing the impedance and increasing the CDC by enlarging the surface area, such as by roughening the surface, or 4 of 11 by adopting new materials such as iridium oxide (IrOx), carbon nanotubes, and poly(3,4-ethylene-dioxythiophene) (PEDOT) (41, 42).”
MethodRight vagus nerve stimulation improves left ventricular function in dogs with heart failure
Sabbah, H. N., Wang, M., Jiang, A., Ruble, S. B., & Hamann, J. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)60152-0 · Cited by 14
Cited by
Zheng, N., Xu, Y., Zhao, Q., & Xie, T. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00938 · Cited by 1,399
Self-citationA Review of Shape Memory Polymers and Composites: Mechanisms, Materials, and Applications
Xia, Y., He, Y., Zhang, F., Liu, Y., & Leng, J. (2021) · Advanced Materials · doi:10.1002/adma.202000713 · Cited by 1,281
Electrical bioadhesive interface for bioelectronics
Deng, J., Yuk, H., Wu, J., Varela, C. E., Chen, X., Roche, E. T., Guo, C. F., & Zhao, X. (2021) · Nature Materials · doi:10.1038/s41563-020-00814-2 · Cited by 727
Self-citationFlexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Metadata
- Authors
- Zhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., Yue, M., Li, Y., Chen, Y., Fu, J., Wu, J., Xie, T., & Feng, X.
- Affiliations
- Tsinghua University (CN)
- State Key Laboratory of Chemical Engineering (CN)
- Institute of Flexible Electronics Technology of THU, Jiaxing 314000, China.
- Corresponding author
- Feng, Xue
- ORCID
- Venue
- Science Advances
- Published
- 2019-04-05
- Volume
- 5
- Issue
- 4
- Pages
- eaaw1066-eaaw1066
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC6505533
- OpenAlex
- W2939525019
- Semantic Scholar
- b3a40db8c16eaf07ed6df41a31d1c7ee4b486e98
- Cited by
- 314
- References
- 56
- Citations by year
- 2026: 22 · 2025: 53 · 2024: 62 · 2023: 42 · 2022: 31 · 2021: 58 · 2020: 34 · 2019: 12
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Science Advances (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (11625207, 11320101001, 11222220)
- National Basic Research Program of China (2015CB351900)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- shape memory polymers, peripheral nerve stimulation, peripheral nerve recording, neural interfaces, stretchable electrodes, vagus nerve stimulation
- MeSH terms
- Action Potentials, Animals, Electric Stimulation, Electrodes, Peripheral Nerves, Polymers, Rabbits, Elastic Modulus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-04, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-04 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.