Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the feasibility of bypassing damaged photoreceptors and electrically stimulating the remaining viable retinal layers to provide limited visual input to patients who are blind because of severe photoreceptor degeneration. METHODS: In the operating room with the patient under local anesthesia, focal electrical stimulation of the retinal surface with brief biphasic pulses was performed using small probes inserted through the sclera. The procedure was performed in five subjects who had little or no light perception. Three subjects had retinitis pigmentosa, one had age-related macular degeneration, and one had unspecified retinal degeneration from birth. RESULTS: Stimulation elicited visual perception of a spot of light (phosphene). Subjects who previously had useful vision accurately localized the phosphenes according to the retinal area stimulated. Two subjects could track the movement of the stimulating electrode by reporting movement of the elicited phosphene, and could perceive two simultaneous phosphenes on independent stimulation with two electrodes. In a resolution test, one of the subjects with no light perception in his left eye resolved phosphenes at 1.75 degrees center-to-center distance (ie, 4/200 OS visual acuity). CONCLUSIONS: Local electrical stimulation of the retinal surface in patients blind from outer retinal disease results in focal light perception that seems to arise from the stimulated area. Such findings in an acute experiment warrant further research into the possibility of prolonged retinal stimulation, improved resolution, and ultimately, an intraocular visual prosthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
An experimental system for auditory image representations
Meijer, P. B. L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121642 · Cited by 900
Nicholls, J. G. (1976) · Cited by 852
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Innate and environmental factors in the development of the kitten's visual cortex.
Blakemore, C., & Van Sluyters, R. C. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010995 · Cited by 685
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 467
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Vitreous Surgery for Hemorrhagic and Fibrous Complications of Age-Related Macular Degeneration
Juan, E. D., & Machemer, R. (1988) · American Journal of Ophthalmology · doi:10.1016/0002-9394(88)90116-x · Cited by 223
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Cited by
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 867
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
“1016/S0042-6989(03)00457-7 to the electrical stimulus (Humayun et al., 1996; Humayun, de Juan, et al., 1999).”
BackgroundInfluentialSelf-citationWill Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationPreservation of the Inner Retina in Retinitis Pigmentosa: A Morphometric Analysis
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 643
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
Self-citationThe Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Retinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476
“As clinical rescue of rods or cones is not yet feasible, cell-based (Young et al., 2000; Coffey et al., 2002) and bionic (Humayun et al., 1996; Chow and Chow, 1997; Zrenner et al., 1998) therapies have been explored as methods to provide surrogate inputs to the surviving neural retina.”
BackgroundRetinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 428
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Self-citationAge-Related Macular Degeneration
Fine, S. L., Berger, J. W., Maguire, M. G., & Ho, A. C. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420707 · Cited by 418
Spatiotemporal dynamics of continuum neural fields
Bressloff, P. C. (2012) · Journal of Physics A: Mathematical and Theoretical · doi:10.1088/1751-8113/45/3/033001 · Cited by 414
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 405
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Self-citationA neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Self-citationRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0819 · Cited by 358
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Poggio, T., & Beymer, D. (1996) · IEEE Spectrum · doi:10.1109/6.490058 · Cited by 332
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Fariss, R. N., Li, Z.-Y., & Milam, A. H. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00401-8 · Cited by 273
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Retinal Remodeling in Inherited Photoreceptor Degenerations
Marc, R. E., & Jones, B. W. (2003) · Molecular Neurobiology · doi:10.1385/mn:28:2:139 · Cited by 258
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
Clinical Characteristics and Current Therapies for Inherited Retinal Degenerations
Sahel, J.-A., Marazova, K., & Audo, I. (2015) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a017111 · Cited by 232
“In IRDs, parts of the inner retina survive even after complete degeneration of the retinal photosensitive layer and remain responsive to electrical simulation even in late stages of the disease (Humayun et al. 1996).”
BackgroundArtificial vision: needs, functioning, and testing of a retinal electronic prosthesis
Chader, G. J., Weiland, J., & Humayun, M. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17522-2 · Cited by 226
“To at least partially answer this question, Humayun et al. (1996) evaluated the direct stimulation of the retinal surface of RP subjects who had little or no light perception.”
BackgroundSelf-citationA Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
Fried, S. I., Hsueh, H. A., & Werblin, F. S. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00849.2005 · Cited by 211
“During clinical trials in patients blind from retinal degenerative diseases, electrical stimulation from electrodes placed close to the ganglion cell layer elicited light percepts (Humayun et al. 1994, 1996; Rizzo et al. 2003a,b).”
BackgroundFactors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Self-citationRetinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 199
Self-citationDemonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189
“Intensity coding was chosen, since it was shown that the dependence of phosphene brightness on stimulus level could be described by a simple saturating power function [1, 6] and as many as 10 intensity levels could be successfully identified by one patient [2], a finding supported by the alpha-IMS trial [9].”
Self-citationImplantation of silicon chip microphotodiode arrays into the cat subretinal space
Chow, A. Y., Pardue, M. T., Chow, V. Y., Peyman, G. A., Liang, C., Perlman, J. I., & Peachey, N. S. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918281 · Cited by 184
“has been found to evoke phosphenes in patients with RP [17] and reproducible cortical potentials in normal animal subjects [18], [19].”
BackgroundA computational model of electrical stimulation of the retinal ganglion cell
Greenberg, R. J., Velte, T. J., Humayun, M. S., Scarlatis, G. N., & De Juan, E. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759051 · Cited by 184
Self-citationWhat blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179
Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Facial Recognition Using Simulated Prosthetic Pixelized Vision
Thompson, R. W., Barnett, G. D., Humayun, M. S., & Dagnelie, G. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0341 · Cited by 175
Self-citationSimulating prosthetic vision: I. Visual models of phosphenes
Chen, S. C., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.003 · Cited by 172
“by Humayun et al. (1999), Lee, Hong, Seo, Tae, and Hong (2000), and Rizzo et al.”
Suaning, G. J., & Lovell, N. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909646 · Cited by 164
“The choice of the maximum full-scale output current in the ASIC has been based, in part, on the results of studies performed by researchers at Johns Hopkins University [7].”
BackgroundMethodResultInfluentialRoska, B., & Sahel, J.-A. (2018) · Nature · doi:10.1038/s41586-018-0076-4 · Cited by 161
Stimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wachtler, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 161
Visually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 160
“It has been shown in this patient population that direct stimulation of the retina with localized currents produces a retinotopically correct visual percept (4).”
BackgroundSelf-citationSputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
“the neuronal network, survive for an extended period of time [1,2].”
BackgroundTissue Damage by Pulsed Electrical Stimulation
Butterwick, A., Vankov, A., Huie, P., Freyvert, Y., & Palanker, D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.908310 · Cited by 136
“Acute and chronic electrical stimulation of the retina in patients with neurodegenerative diseases using arrays containing up to 16 electrodes has demonstrated the possibility of imparting perception of light, the detection of motion, and even simple shape discrimination [8], [9].”
BackgroundElectronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
“To date, a number of experiments performed in sighted and blind human subjects demonstrate the potential for epiretinal electrical stimulation to provide patterned visual perception (6, 7, 39, 40).”
BackgroundMethodImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Lewis, P. M., & Rosenfeld, J. V. (2016) · Brain Research · doi:10.1016/j.brainres.2015.08.038 · Cited by 107
Preliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
Humayun, M. S., Dorn, J. D., Ahuja, A. K., Caspi, A., Filley, E., Dagnelie, G., Salzmann, J., Santos, A., Duncan, J., daCruz, L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5332695 · Cited by 100
Self-citationDagnelie, G., Barnett, D., Humayun, M. S., & Thompson, R. W. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0157 · Cited by 90
Self-citationArtificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Self-citationPsychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
“Although some long-held tenets of neuroscience have had to yield to the reality of phosphenes elicited through intraocular stimulation (21, 22), others stand unchallenged.”
BackgroundFinn, A., Grewal, D., & Vajzovic, L. (2018) · Clinical ophthalmology · doi:10.2147/opth.s137525 · Cited by 71
Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
“In simulated prosthetic vision (SPV), electrical stimulation is applied to the user through electrodes implanted in the eye [25, 58, 59].”
BackgroundLi, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59
New Vision for Visual Prostheses
Farnum, A., & Pelled, G. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00036 · Cited by 58
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
Luo, Y. H.-L., Zhong, J. J., Clemo, M., & da Cruz, L. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.021 · Cited by 47
Sabbah, N., Authie, C. N., Sanda, N., Mohand-Said, S., Sahel, J.-A., & Safran, A. B. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15392 · Cited by 45
Simulations of Electrode Placement for a Thalamic Visual Prosthesis
Pezaris, J. S., & Reid, R. C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005973 · Cited by 45
Development of very large electrode arrays for epiretinal stimulation (VLARS)
Waschkowski, F., Hesse, S., Rieck, A. C., Lohmann, T., Brockmann, C., Laube, T., Bornfeld, N., Thumann, G., Walter, P., Mokwa, W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-11 · Cited by 43
“Since it has been demonstrated that blind RP subjects were able to detect light spots and patterns by electrical stimulation of the retina [4–6] visual prostheses have been fabricated, approved, and used in RP patients”
BackgroundThe response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38
“Cells were classified as brisk transient/alpha cells (BT) if they responded with high frequency and transient bursts of spiking to stimuli centered in their receptive field [1, 4, 5].”
BackgroundMethodPlaying checkers: detection and eye–hand coordination in simulated prosthetic vision
Dagnelie, G., Walter, M., & Yang, L. (2006) · Journal of Modern Optics · doi:10.1080/09500340600619197 · Cited by 36
Merabet, L. B., Rizzo, J. F., Pascual-Leone, A., & Fernandez, E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s15 · Cited by 35
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Chen, S. C., Hallum, L. E., Suaning, G. J., & Lovell, N. H. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s13 · Cited by 31
The argus ii retinal prosthesis system
Bloch, E., & da Cruz, L. (2020) · Prosthesis · doi:10.5772/intechopen.84947 · Cited by 31
Eggenberger, S. C., James, N. L., Ho, C., Eamegdool, S. S., Tatarinoff, V., Craig, N. A., Gow, B. S., Wan, S., Dodds, C. W. D., La Hood, D., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121191 · Cited by 21
Retinal prostheses: where to from here?
Allen, P. J. (2021) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13950 · Cited by 20
“Stimulation in these five patients determined that simultaneous phosphenes could be perceived and movement of the electrode could be tracked by movement of the phosphenes.(24) In another study by Rizzo's group, one normal patient and four patients with end stage RP were stimulated with a short-term epiretinal array, o…”
BackgroundAdvances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Neural Activity Shaping in Visual Prostheses with Deep Learning
Castro, D., Grayden, D. B., Meffin, H., & Spencer, M. (2023) · doi:10.1101/2023.12.20.572123 · Cited by 4
Metadata
- Authors
- Humayun, M. S.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1996-01-01
- Volume
- 114
- Issue
- 1
- Pages
- 40
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2007409841
- Cited by
- 601
- References
- 18
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.