Visual Prostheses in the Era of Artificial Intelligence Technology
Open accessThe DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index; 58 of the 88 sources its claims cite were checked for support.
Abstract
Background: Over the past few decades, technological advancements have transformed invasive visual prostheses from theoretical concepts into real-world applications. However, functional outcomes remain limited, especially in visual acuity. This review aims to summarize current developments in retinal and cortical prostheses (RCPs) and critically assess the role of artificial intelligence (AI) in advancing these systems. Purpose: To describe current RCPs and provide a systematic review on image and signal processing algorithms designed for improved clinical outcomes. Patients and Methods: We performed a systematic review of the literature related to AI subserving prosthetic vision, using mainly PubMed, but also, Elicit, a dedicated AI-based reference research assistant. A total of 455 studies were screened on PubMed, of which 23 were retained for inclusion. An additional 5 studies were identified and included through Elicit. Results: The analysis of current RCPs highlights various limitations affecting the quality of the visual flow provided by current artificial vision. Indeed, the 28 reviewed studies on AI covered two applications for RCPs including extraction of saliency in camera captured images, and consistency between electrical stimulation and perceived phosphenes. A total of 14 out of 28 studies involved the use of artificial neural networks, of which 12 included model training. Evaluation with data from a visual prosthesis was conducted in 7 studies, including 1 that was prospectively assessed with a human RCP. Validation with empirical data from human or animal data was performed in 22 out of 28 studies. Out of these, 15 were validated using simulated prosthetic vision. Finally, out of 22 studies leveraging a mathematical model for phosphenes perception, 14 used a symmetrical oversimplified modeling. Conclusion: AI algorithms show promise in optimizing prosthetic vision, particularly through enhanced image saliency extraction and stimulation strategies. However, most current studies are based on simulations. Further development and validation in real-world settings, especially through clinical testing with blind patients, are essential to assess their true effectiveness.
Overview
CoChat Summary
TL;DR
This systematic review examines retinal and cortical prostheses and AI/image-processing methods intended to improve prosthetic vision, identifying saliency extraction and stimulation–phosphene consistency as the two main applications. It finds most AI studies rely on simulations and oversimplified phosphene models, with limited validation in real prosthetic users.
Key findings
- Of 455 PubMed records screened, 23 met inclusion criteria and 5 additional studies were identified via Elicit, yielding 28 AI studies; 14/28 used artificial neural networks, and 12 included model training.
- Validation was mostly indirect: 22/28 studies used empirical human or animal data, 15 used simulated prosthetic vision, 7 used data from a visual prosthesis, and only 1 was prospectively assessed with a human RCP.
- Among 22 studies using a mathematical model of phosphene perception, 14 used symmetrical oversimplified modeling; only 8 used asymmetric models, including 5 with an axon-map model.
- AI applications split into saliency extraction from camera-captured images and optimization of consistency between electrical stimulation and perceived phosphenes; 12/28 studies included dynamic aspects of vision, while 16/28 considered only static measurements or images.
Methods
- Systematic review of literature on AI, machine learning, or image processing for retinal and cortical prostheses, mainly using PubMed plus Elicit; 455 studies were screened, 23 retained, and 5 added through Elicit, for 28 total studies; search last updated January 2025.
- One author (IS) extracted data on publication year, purpose, AI techniques, parameter tuning, phosphene assumptions, validation setting, human tasks, dynamic scenes, and electrode count, with study-by-study details in Table 2 and supplementary tables.
- The paper also provides a narrative overview of current retinal prostheses (epiretinal, subretinal, suprachoroidal) and cortical prostheses, plus methodological, clinical, and technological challenges.
Limitations
- Stated: most current AI studies are based on simulations; few are validated in real-world settings; only one study included an implanted human participant; oversimplified symmetrical phosphene models may inflate apparent performance and mask safety constraints; reviewed virtual-setting studies did not quantitatively assess safety limits, power draw, robustness stress-tests, uncertainty tracking, or fail-safes; heterogeneous tasks, metrics, datasets, and electrode counts hamper cross-study interpretation and benchmarking.
- Evident from the text: screening and data extraction were performed by a single author (IS), which may limit reliability, and the synthesis is descriptive rather than meta-analytic.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
39 Valid · 16 Not valid · 14 Not checked · 114 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In the case of cortical prostheses, phosphene location depends on numerous factors, including the individual’s specific retinotopic maps and displacement or degradation of the cortical implant over time.58”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Methodological, Clinical, and Technological Challenges Associated with RCPs
What the sources say
- Partly supportedcites [58] Towle, 2020, J Neural Eng sourceExperimental — accuracy not yet measured
Section 3.2 links electrode position relative to cortical sulci with where phosphenes appeared, and the Abstract reports that the array rotated over time. But section 4.4 says this subject’s unusual phosphene pattern could not be explained by unusual cortical anatomy, while section 4.2 documents electrode degradation without showing that it changed phosphene locations. The paper therefore supports implant placement as relevant, but not all the claimed factors as determinants of location. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Of note, stimulation of the visual cortex in congenitally blind individuals can inadvertently produce tactile sensations rather than visual phosphenes, particularly in blind subjects who had undertaken extensive training with sensory substitution systems.39–41”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Cortical Prostheses
What the sources say
- Not checked — no full text of the sourcecites [39] Kupers, 2006, Proc Natl Acad Sci source
- Not checked — no full text of the sourcecites [40] Ptito, 2007, Exp Brain Res source
- Could not verifycites [41] Kupers, 2010, Proc Natl Acad Sci sourceExperimental — accuracy not yet measured
The Abstract and Discussion describe visual-cortex activation during a tactile route-recognition task after sensory-substitution training, not sensations produced by stimulating the cortex. A title listed in the References mentions stimulation-induced qualia, but our copy does not say whether these were tactile rather than visual phosphenes or whether extensive training affected them (searched: phosphenes, stimulation-induced tactile sensations). (LLM, conf=0.74)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In comparison, studies on suprachoroidal devices25,36 have generally assessed patient autonomy, mobility, and object discrimination, rather than visual acuity.”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Methodological, Clinical, and Technological Challenges Associated with RCPs
What the sources say
- Partly supportedcites [25] Petoe, 2021, Transl Vis Sci Amp Technol sourceExperimental — accuracy not yet measured
The Methods sections on Tabletop Search and FLORA assess object identification, daily activities, and mobility, supporting the description of this trial’s emphasis. But the Methods and Results sections on Screen-based Assessments also report a Basic Grating Acuity test, so visual acuity was not wholly set aside. This single trial also does not establish what suprachoroidal-device studies have generally assessed; the indexed passages provide no page numbers. (LLM, conf=0.84)
- Not checked — no full text of the sourcecites [36] Fujikado, 2016, Investig Opthalmol Amp Vis Sci source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The Argus II and PRIMA devices were designed to reduce FOV even further, thereby providing improved image resolution through a digital zoom.9,10,65”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Methodological, Clinical, and Technological Challenges Associated with RCPs
What the sources say
- Not checked — no full text of the sourcecites [9] Luo, 2016, Prog Retin Eye Res source
- Partly supportedcites [10] Palanker, 2022, Nat Commun sourceExperimental — accuracy not yet measured
The Results report that PRIMA-2 offers electronic magnification, and the Discussion reports improved acuity with magnification. But the paper does not say Argus II and PRIMA were designed to reduce field of view for that purpose; the Results give PRIMA-2 a slightly wider projected field than PRIMA-1 (18.5° versus 17.5°). Argus II appears only in a reference, not in this design comparison. (LLM, conf=0.88)
- Not matchedcites [65] Sahel, 2013, Invest Ophthalmol Vis Sci
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, empirical data show that phosphenes are not symmetric, either for retinal101 or cortical42 implants.”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Saliency Extraction
What the sources say
- Supportedcites [101] Hou, 2024, J Neural Eng source
The Introduction says phosphenes from a single Argus II retinal electrode are predominantly elongated along underlying nerve fiber bundles. The Results section also reports that more eccentric phosphenes tended to be more elongated in one participant. This supports the retinal-implant portion of the sentence, to which this source is cited; the cortical-implant portion has a separate citation. (LLM, conf=0.90)
- Partly supportedcites [42] Fernández, 2021, J Clin Invest sourceExperimental — accuracy not yet measured
For the cortical-implant portion of the sentence, the Results report that the participant perceived more elongated phosphenes as the distance between two stimulated electrodes increased. This supports the narrower point that cortical stimulation can produce non-round percepts, but it does not establish that cortical phosphenes are generally asymmetric. The retinal-implant portion is attributed to a different citation. (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
83 more claims · 13 with their cited sources checked
Create a free account to see all 183 claims and to verify the 1 reference still open.
- It may state two separate claims as one. 54
- Probably not a substantial claim. 55
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Systematic Review on the Use of AI for RCPs
“| [90] | 2022 | Saliency Extraction | TF | None | None |”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > References
“90. White J, Ruiz-Serra J, Petrie S, Kameneva T, McCarthy C. Self-attention based vision processing for prosthetic vision. In: 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE; 2023: 1– 4.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Saliency Extraction
“Among the 14-feature engineering-based studies identified in our literature search, the most common feature type used for saliency map extraction was image contours”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Saliency Extraction
“Only one out of the 15 feature engineering studies has been implemented in human real prosthetic vision settings77 with a suprachoroidal device.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Systematic Review on the Use of AI for RCPs
“| [96] | 2023 | SP Optimization | NN, ML | RSPV data | No |”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > References
“96. Fauvel T, Chalk M. Human-in-the-loop optimization of visual prosthetic stimulation. J Neural Eng. 2022; 19: 036038.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Retinal and Cortical Prostheses
“The 245 electrode IMIE 256 developed by IntelliMicro Medical (China) and Golden Eye Bionics (US)23 is currently the only epiretinal prosthesis undergoing evaluation in humans.”
§ Visual Prostheses in the Era of Artificial Intelligence Technology > Introduction > Cortical Prostheses
“| | PRIMA | Argus II | Alpha-AMS | STS | SRP | IMIE | | --- | --- | --- | --- | --- | --- | --- | | Type | Sub. | Epi. | Sub. | Supra. | Supra. | Epi. | | Clinical Target | GA | RP | RP | RP | RP | RP | | Electrodes | 378 | 60 | 1600 | 49 | 49 | 256 |”
Citations
Cites
Vaswani, A., Shazeer, N., Parmar, N., Uszkoreit, J., Jones, L., Gomez, A. N., Kaiser, L., & Polosukhin, I. (2017) · arXiv · doi:10.48550/arxiv.1706.03762 · Cited by 120,404
Exploiting Generative AI to Scale up Intelligent Tutoring Systems
Jakubův, J., Chvalovský, K., Goertzel, Z., Kaliszyk, C., Olšák, M., Piotrowski, B., Schulz, S., Suda, M., & Urban, J. (2023) · DROPS (Schloss Dagstuhl – Leibniz Center for Informatics) · doi:10.4230/lipics.itp.2023.19 · Cited by 76,658
Neural Mechanisms of Selective Visual Attention
Desimone, R., & Duncan, J. (1995) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.18.030195.001205 · Cited by 8,388 · cited 1×
“105 With artificial vision, the dynamics of extrapolation achieved through multiple views of the same scene may convey crucial information to blind patients.”
Bourne, R. R. A., Flaxman, S. R., Braithwaite, T., Cicinelli, M. V., Das, A., Jonas, J. B., Keeffe, J., Kempen, J. H., Leasher, J., Limburg, H., et al. (2017) · The Lancet Global Health · doi:10.1016/s2214-109x(17)30293-0 · Cited by 2,213
Bourne, R., Steinmetz, J. D., Flaxman, S., Briant, P. S., Taylor, H. R., Resnikoff, S., Casson, R. J., Abdoli, A., Abu-Gharbieh, E., Afshin, A., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30425-3 · Cited by 1,431
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 2×
“In 1968, the first proof-of-concept was provided that focal electrical stimulation of the human visual cortex can evoke discrete phosphenes, 37 paving the way for later cortical visual-prosthesis research.”
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 2×
“20 In 2001, the American company “Second Sight” developed the first modern epiretinal device 18 designed for blind individuals blinded from outer retinal degenerative disease.”
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511 · cited 1×
“Among the various models, Artificial Silicon Retina (ASR) retinal implant 30 developed by “Optobionics” (USA) was the first to receive FDA approval, in 2000.”
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · cited 4×
“9,10,22,24 By this metric, comparison of visual acuity with the device switched ON and OFF showed improvement only for the PRIMA 35 and Argus II 9 devices.”
InfluentialDobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440 · cited 1×
“In the 1970s, the Dobelle Eye, 38 consisting of 68 platinum electrodes connected to a camera, was implanted in a blind adult patient.”
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · cited 2×
“Some studies have proposed adapting stimulation rates 9,21 or electrical stimulation intensity 25,36 to individual cases.”
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333 · cited 1×
“9,10,22,24 By this metric, comparison of visual acuity with the device switched ON and OFF showed improvement only for the PRIMA 35 and Argus II 9 devices.”
Striem-Amit, E., Cohen, L., Dehaene, S., & Amedi, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.08.026 · Cited by 294
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., et al. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151331 · Cited by 246 · cited 1×
“However, empirical data show that phosphenes are not symmetric, either for retinal 101 or cortical 42 implants.”
Vision Loss Expert Group of the Global Burden of Disease Study, Pesudovs, K., Lansingh, V. C., Kempen, J. H., Tapply, I. H., Fernandes, A. G., Cicinelli, M. V., Arrigo, A., Leveziel, N., Resnikoff, S., et al. (2024) · Eye · doi:10.1038/s41433-024-02961-1 · Cited by 244
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227 · cited 8×
“The failure to demonstrate long-term and clinically meaningful benefits has led companies supporting the three currently most studied retinal prostheses (Alpha-AMS, Argus II, PRIMA) to cease or redirect their activity in RCP research and development.”
InfluentialSimulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193 · cited 1×
“34 Although both devices obtained CE marking, they were never commercialized due to their insufficient technological and clinical performance, and the company was dissolved in 2019.”
Neural correlates of virtual route reCognition in congenital blindness
Kupers, R., Chebat, D. R., Madsen, K. H., Paulson, O. B., & Ptito, M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006199107 · Cited by 187 · cited 1×
“41”
Self-citationDesign and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183 · cited 1×
“27 So far, these devices have only been evaluated in animal models.”
Jansonius, N. M., Nevalainen, J., Selig, B., Zangwill, L. M., Sample, P. A., Budde, W. M., Jonas, J. B., Lagrèze, W. A., Airaksinen, P. J., Vonthein, R., et al. (2009) · Vision Research · doi:10.1016/j.visres.2009.04.029 · Cited by 155 · cited 2×
“57,102,103 Twelve out of 28 studies leveraged parameters optimization, indicating that AI algorithms were trained in an original fashion (data or architecture).”
Simultaneous perception of prosthetic and natural vision in AMD patients
Palanker, D., Le Mer, Y., Mohand-Said, S., & Sahel, J. A. (2022) · Nature Communications · doi:10.1038/s41467-022-28125-x · Cited by 140 · cited 3×
“9,10,22,24 By this metric, comparison of visual acuity with the device switched ON and OFF showed improvement only for the PRIMA 35 and Argus II 9 devices.”
Kupers, R., Fumal, A., de Noordhout, A. M., Gjedde, A., Schoenen, J., & Ptito, M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602925103 · Cited by 122
Self-citationNeuroprotective Effect of Subretinal Implants in the RCS Rat
Pardue, M. T., Phillips, M. J., Yin, H., Sippy, B. D., Webb-Wood, S., Chow, A. Y., & Ball, S. L. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0515 · Cited by 117
TMS of the occipital cortex induces tactile sensations in the fingers of blind Braille readers
Ptito, M., Fumal, A., de Noordhout, A. M., Schoenen, J., Gjedde, A., & Kupers, R. (2008) · Experimental Brain Research · doi:10.1007/s00221-007-1091-0 · Cited by 113
Self-citationSimulation of artificial vision: I. Eccentric reading of isolated words, and perceptual learning
Sommerhalder, J., Oueghlani, E., Bagnoud, M., Leonards, U., Safran, A. B., & Pelizzone, M. (2003) · Vision Research · doi:10.1016/s0042-6989(02)00481-9 · Cited by 111
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101 · cited 4×
“In comparison, studies on suprachoroidal devices 25,36 have generally assessed patient autonomy, Notes : The main retinal prostheses and their features, including their anatomical localization, the targeted condition, their performance, methods of evaluation.”
InfluentialOn Mobility Aids for the Blind
Collins, C. C. (1985) · Springer eBooks · doi:10.1007/978-94-017-1400-6_4 · Cited by 70
A Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis: Interim Clinical Trial Results
Petoe, M. A., Titchener, S. A., Kolic, M., Kentler, W. G., Abbott, C. J., Nayagam, D. A. X., Baglin, E. K., Kvansakul, J., Barnes, N., Walker, J. G., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.12 · Cited by 63 · cited 4×
“In comparison, studies on suprachoroidal devices 25,36 have generally assessed patient autonomy, Notes : The main retinal prostheses and their features, including their anatomical localization, the targeted condition, their performance, methods of evaluation.”
InfluentialPossible sources of neuroprotection following subretinal silicon chip implantation in RCS rats
Pardue, M. T., Phillips, M. J., Yin, H., Fernandes, A., Cheng, Y., Chow, A. Y., & Ball, S. L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/006 · Cited by 62
Semantic and structural image segmentation for prosthetic vision
Sanchez-Garcia, M., Martinez-Cantin, R., & Guerrero, J. J. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227677 · Cited by 62 · cited 4×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
InfluentialPOLYRETINA restores light responses in vivo in blind Göttingen minipigs
Vagni, P., Airaghi Leccardi, M. J. I., Vila, C.-H., Zollinger, E. G., Sherafatipour, G., Wolfensberger, T. J., & Ghezzi, D. (2022) · Nature Communications · doi:10.1038/s41467-022-31180-z · Cited by 62 · cited 1×
“28,29”
Neurolight: A Deep Learning Neural Interface for Cortical Visual Prostheses
Lozano, A., Suárez, J. S., Soto-Sánchez, C., Garrigós, J., Martínez-Alvarez, J. J., Ferrández, J. M., & Fernández, E. (2020) · International Journal of Neural Systems · doi:10.1142/s0129065720500458 · Cited by 57
Finger, R. P., Tellis, B., Crewe, J., Keeffe, J. E., Ayton, L. N., & Guymer, R. H. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14731 · Cited by 55
Performance of visually guided tasks using simulated prosthetic vision and saliency-based cues
Parikh, N., Itti, L., Humayun, M., & Weiland, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026017 · Cited by 54 · cited 1×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
End-to-end optimization of prosthetic vision
de Ruyter van Steveninck, J., Güçlü, U., van Wezel, R., & van Gerven, M. (2020) · doi:10.1101/2020.12.19.423601 · Cited by 54 · cited 3×
“Of the five end-to-end studies that we identified, two relied on auto-encoding strategies, 88,91 where the task to be learnt is reconstructing an original image, and three entailed reinforcement learning approaches, 87,89,90 for which the scope of learned tasks is wider.”
End-to-end optimization of prosthetic vision
de Ruyter van Steveninck, J., Güçlü, U., van Wezel, R., & van Gerven, M. (2022) · Journal of Vision · doi:10.1167/jov.22.2.20 · Cited by 54
de Ruyter van Steveninck, J., van Gestel, T., Koenders, P., van der Ham, G., Vereecken, F., Güçlü, U., van Gerven, M., Güçlütürk, Y., & van Wezel, R. (2022) · Journal of Vision · doi:10.1167/jov.22.2.1 · Cited by 51
Preliminary report on a retinal stimulator.
Ge, T. (1956) · PubMed · Cited by 50
The Subretinal Microphotodiode Array Retinal Prosthesis
Chow, A. Y., & Peachey, N. S. (1998) · Ophthalmic Research · doi:10.1159/000055474 · Cited by 50 · cited 1×
“Renewed interest in retinal implants appeared only later during the 1990s with two parallel lines of work (Figure 2): (i) sub-retinal micro-photodiode arrays, 17 and (ii) epiretinal multielectrode arrays.”
Humayun, M. S., & de Juan, E. (1998) · Eye · doi:10.1038/eye.1998.151 · Cited by 50 · cited 1×
“20 In 2001, the American company “Second Sight” developed the first modern epiretinal device 18 designed for blind individuals blinded from outer retinal degenerative disease.”
Finger, R. P., McSweeney, S. C., Deverell, L., O’Hare, F., Bentley, S. A., Luu, C. D., Guymer, R. H., & Ayton, L. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14732 · Cited by 49
Mobility and low contrast trip hazard avoidance using augmented depth
McCarthy, C., Walker, J. G., Lieby, P., Scott, A., & Barnes, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016003 · Cited by 49 · cited 3×
“In an alternate approach, adaptive depth-contrast enhancement was proposed for improving obstacle detection in the path of a moving person, 76 with validation of the saliency maps through performance of visual or mobility tasks.”
Luo, Y. H.-L., Zhong, J. J., Clemo, M., & da Cruz, L. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.021 · Cited by 47 · cited 1×
“However, individual phosphenes can vary in shape, size, and location among patients, 19 and their number is limited by the design of the array of stimulators.”
Vision function testing for a suprachoroidal retinal prosthesis: effects of image filtering
Barnes, N., Scott, A. F., Lieby, P., Petoe, M. A., McCarthy, C., Stacey, A., Ayton, L. N., Sinclair, N. C., Shivdasani, M. N., Lovell, N. H., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036013 · Cited by 46 · cited 2×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
The Intracortical Visual Prosthesis Project
Troyk, P. R. (2017) · Artificial Vision · doi:10.1007/978-3-319-41876-6_16 · Cited by 45 · cited 1×
“Most recently, the Intracortical Visual Prosthesis project (ICVP) 45 was developed at the Illinois Institute of Technology.”
Brain-Machine Interfaces to Assist the Blind
Ptito, M., Bleau, M., Djerourou, I., Paré, S., Schneider, F. C., & Chebat, D.-R. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.638887 · Cited by 45
Self-citationAdvances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43 · cited 1×
“55,56 Understanding the Phosphenes From a neurobiological point of view, the link between electrical stimulation and perception of phosphenes is still not well understood.”
First Human Results With the 256 Channel Intelligent Micro Implant Eye (IMIE 256)
Xu, H., Zhong, X., Pang, C., Zou, J., Chen, W., Wang, X., Li, S., Hu, Y., Sagan, D. S., Weiss, P. T., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.14 · Cited by 43 · cited 1×
“The 245 electrode IMIE 256 developed by IntelliMicro Medical (China) and Golden Eye Bionics (US) 23 is currently the only epiretinal prosthesis undergoing evaluation in humans.”
van der Grinten, M., de Ruyter van Steveninck, J., Lozano, A., Pijnacker, L., Rueckauer, B., Roelfsema, P., van Gerven, M., van Wezel, R., Güçlü, U., & Güçlütürk, Y. (2024) · eLife · doi:10.7554/elife.85812 · Cited by 39 · cited 2×
“57,102,103 Twelve out of 28 studies leveraged parameters optimization, indicating that AI algorithms were trained in an original fashion (data or architecture).”
Region-of-interest processing for electronic visual prostheses
Boyle, J. R., Maeder, A. J., & Boles, W. W. (2008) · Journal of Electronic Imaging · doi:10.1117/1.2841708 · Cited by 36 · cited 2×
“72 The authors proposed an adaptive design by applying weights on each feature depending on the scene context.”
Restoration of vision using wireless cortical implants: The Monash Vision Group project
Lowery, A. J., Rosenfeld, J. V., Lewis, P. M., Browne, D., Mohan, A., Brunton, E., Yan, E., Maller, J., Mann, C., Rajan, R., et al. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318543 · Cited by 35
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35 · cited 1×
“Initial animal tests indicated a good safety profile, 44 encouraging the group to apply for funding to perform a clinical trial with a 73 electrodes device.”
Thorn, J. T., Migliorini, E., & Ghezzi, D. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb5bc · Cited by 34 · cited 2×
“64 However, the mean FOV of the latest generation of retinal prostheses is only 28 degrees, as compared to 135 degrees horizontal and over 180 degrees vertical for the human eye.”
Caspi, A., Barry, M. P., Patel, U. K., Salas, M. A., Dorn, J. D., Roy, A., Niketeghad, S., Greenberg, R. J., & Pouratian, N. (2021) · Brain Stimulation · doi:10.1016/j.brs.2021.04.019 · Cited by 32 · cited 1×
“58 Gaze orientation also plays an important role in both phosphenes location 59 and interpretability for mobility and visual tasks.”
1024-channel electrophysiological recordings in macaque V1 and V4 during resting state
Chen, X., Morales-Gregorio, A., Sprenger, J., Kleinjohann, A., Sridhar, S., van Albada, S. J., Grün, S., & Roelfsema, P. R. (2022) · Scientific Data · doi:10.1038/s41597-022-01180-1 · Cited by 32
Lu, G., Gong, C., Sun, Y., Qian, X., Nair, D. S. R., Li, R., Zeng, Y., Ji, J., Zhang, J., Kang, H., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48683-6 · Cited by 32
Optimization of Neuroprosthetic Vision via End-to-End Deep Reinforcement Learning
Küçükoğlu, B., Rueckauer, B., Ahmad, N., van Steveninck, J. D. R., Güçlü, U., & van Gerven, M. A. J. (2022) · International Journal of Neural Systems · doi:10.1142/s0129065722500526 · Cited by 32
Chen, S. C., Hallum, L. E., Suaning, G. J., & Lovell, N. H. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s13 · Cited by 31
Simplification of Visual Rendering in Simulated Prosthetic Vision Facilitates Navigation
Vergnieux, V., Macé, M. J.-M., & Jouffrais, C. (2017) · Artificial Organs · doi:10.1111/aor.12868 · Cited by 30 · cited 1×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
Status of the feline retina 5 years after subretinal implantation
Pardue, M. T., Ball, S. L., Phillips, M. J., Faulkner, A. E., Walker, T. A., Chow, A. Y., & Peachey, N. S. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.07.0118 · Cited by 28 · cited 1×
“However, the increased visual acuity experience by recipients with the device ON proved to reflect a neuroprotective effect from the electrical stimulation, rather than elicitation of phosphenes, 31–33 leading the company to discontinue this project.”
Optimization of visual information presentation for visual prosthesis
Guo, F., Yang, Y., & Gao, Y. (2018) · International Journal of Biomedical Imaging · doi:10.1155/2018/3198342 · Cited by 27 · cited 1×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
Flexible Polymer Electrodes for Stable Prosthetic Visual Perception in Mice
Orlemann, C., Boehler, C., Kooijmans, R. N., Li, B., Asplund, M., & Roelfsema, P. R. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304169 · Cited by 27 · cited 1×
“67 Recently, the use of flexible electrodes instead of a rigid array 68 has been proposed to cover a bigger surface of the visual field compared with surface Utah arrays.”
Optimization of Neuroprosthetic Vision via End-to-end Deep Reinforcement Learning
Küçükoğlu, B., Rueckauer, B., Ahmad, N., de Ruyter van Steveninck, J., Güçlü, U., & van Gerven, M. (2022) · doi:10.1101/2022.02.25.482017 · Cited by 25 · cited 2×
“Of the five end-to-end studies that we identified, two relied on auto-encoding strategies, 88,91 where the task to be learnt is reconstructing an original image, and three entailed reinforcement learning approaches, 87,89,90 for which the scope of learned tasks is wider.”
Transformative Reality: Improving bionic vision with robotic sensing
Lui, W. L. D., Browne, D., Kleeman, L., Drummond, T., & Li, W. H. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6345929 · Cited by 23 · cited 1×
“15, 70 We have performed a systematic review of the literature to identify algorithms which use machine learning, AI, or image processing methods for optimizing stimulation protocols.”
Bleau, M., Paré, S., Chebat, D., Kupers, R. C., Nemargut, J. P., & Ptito, M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1010354 · Cited by 22
Self-citationA novel interface for cortical columnar neuromodulation with multipoint infrared neural stimulation
Tian, F., Zhang, Y., Schriver, K. E., Hu, J. M., & Roe, A. W. (2024) · Nature Communications · doi:10.1038/s41467-024-50375-0 · Cited by 21
Assessing the utility of visual acuity measures in visual prostheses
Caspi, A., & Zivotofsky, A. Z. (2015) · Vision Research · doi:10.1016/j.visres.2015.01.006 · Cited by 20
Strickland, E., & Harris, M. (2022) · IEEE Spectrum · doi:10.1109/mspec.2022.9729945 · Cited by 19 · cited 1×
“Unfortunately, maintenance support of the Argus II was discontinued in 2020 26 due to financial reasons.”
Fine, I., & Boynton, G. M. (2024) · Scientific Reports · doi:10.1038/s41598-024-65337-1 · Cited by 19 · cited 1×
“103,104 The Polyretina team also conducted experiments within virtual reality to assess perception under simulated epiretinal prosthetic vision.”
Plastic Brain Mechanisms in Sensory Substitution
Bach-y-Rita, P. (1975) · Cerebral Localization · doi:10.1007/978-3-642-66204-1_16 · Cited by 18
Pesudovs, K., N/A Vision Loss Expert Group of the Global Burden of Disease Study, & Collaborators, G. 2. B. A. V. I. C. G. 2. B. A. V. I. (2023) · Research Square · doi:10.21203/rs.3.rs-3160383/v1 · Cited by 18
Martínez-Álvarez, A., Crespo-Cano, R., Díaz-Tahoces, A., Cuenca-Asensi, S., Ferrández Vicente, J. M., & Fernández, E. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500210 · Cited by 17 · cited 1×
“Two studies were evaluated in a mouse model involving the transduction of a calcium indicator 94 and electrophysiological measurements 93 in RGCs to provide an objective measurement of their activity.”
Schaffrath, K., Lohmann, T., Seifert, J., Ingensiep, C., Raffelberg, P., Waschkowski, F., Viga, R., Kokozinski, R., Mokwa, W., Johnen, S., et al. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00938-9 · Cited by 17
Recognition of Objects in Simulated Irregular Phosphene Maps for an Epiretinal Prosthesis
Lu, Y., Wang, J., Wu, H., Li, L., Cao, X., & Chai, X. (2014) · Artificial Organs · doi:10.1111/aor.12174 · Cited by 16 · cited 1×
“Other features included contrast information, 73,76 semantic information, 80,82,83 depth information, 76,79,81 surface normal, 84 convolutional filters, 73,75,77 and the use of clip-art style images.”
Prosthetic Visual Performance Using a Disparity-Based Distance-Filtering System
Kartha, A., Sadeghi, R., Barry, M. P., Bradley, C., Gibson, P., Caspi, A., Roy, A., & Dagnelie, G. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.12.27 · Cited by 16
Toward a personalized closed-loop stimulation of the visual cortex: Advances and challenges
Grani, F., Soto-Sánchez, C., Fimia, A., & Fernández, E. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1034270 · Cited by 16 · cited 1×
“55,56 Understanding the Phosphenes From a neurobiological point of view, the link between electrical stimulation and perception of phosphenes is still not well understood.”
Advances and challenges in the development of visual prostheses
Fernandez, E., & Robles, J. A. (2024) · PLOS Biology · doi:10.1371/journal.pbio.3002896 · Cited by 16 · cited 1×
“The method design must result in an encoding scheme that favors the extraction of salient features and may also encompass optimization of the visual flow by considering models for perception of phosphenes.”
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Precise control of neural activity using dynamically optimized electrical stimulation
Shah, N. P., Phillips, A., Madugula, S., Lotlikar, A., Gogliettino, A. R., Hays, M. R., Grosberg, L., Brown, J., Dusi, A., Tandon, P., et al. (2024) · eLife · doi:10.7554/elife.83424 · Cited by 15
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7615 · Cited by 15 · cited 2×
“96,99 This approach allowed inclusion of patient’s preferences for stimulation parameters optimization and was proposed in two studies, one using virtual patients 96 and one using real sighted patients under SPV. 99 This approach might allow simultaneous optimization of the saliency extraction and…”
Simulated Prosthetic Vision: Improving text accessibility with retinal prostheses
Denis, G., Jouffrais, C., Mailhes, C., & Macé, M. J. ‐. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943939 · Cited by 14
Deep reinforcement learning for task-based feature learning in prosthetic vision
White, J., Kameneva, T., & McCarthy, C. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856541 · Cited by 14 · cited 2×
“Of the five end-to-end studies that we identified, two relied on auto-encoding strategies, 88,91 where the task to be learnt is reconstructing an original image, and three entailed reinforcement learning approaches, 87,89,90 for which the scope of learned tasks is wider.”
Large-scale multimodal surface neural interfaces for primates
Belloir, T., Vargo, S. M., Ahmed, Z., Griggs, D. J., Fisher, S., Brown, T., Chamanzar, M., & Yazdan-Shahmorad, A. (2022) · iScience · doi:10.1016/j.isci.2022.105866 · Cited by 14 · cited 1×
“67 Recently, the use of flexible electrodes instead of a rigid array 68 has been proposed to cover a bigger surface of the visual field compared with surface Utah arrays.”
Axonal stimulation affects the linear summation of single-point perception in three Argus II users
Hou, Y., Nanduri, D., Granley, J., Weiland, J. D., & Beyeler, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad31c4 · Cited by 14 · cited 2×
“101 Finally, 5 studies did not use prior on phosphene shapes, and these were conducted with empirically measured data.”
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2018) · doi:10.1101/453035 · Cited by 13
Transformative reality: Augmented reality for visual prostheses
Lui, W. L. D., Browne, D., Kleeman, L., Drummond, T., & Li, W. H. (2011) · 2011 10th IEEE International Symposium on Mixed and Augmented Reality · doi:10.1109/ismar.2011.6092402 · Cited by 12 · cited 1×
“69 Indeed, applying AI to optimize the highly constrained visual information flow conveyed to the blind might provide valuable benefits for the user.”
Postmortem investigation of a human cortical visual prosthesis that was implanted for 36 years
Towle, V. L., Pytel, P., Lane, F., Plass, J., Frim, D. M., & Troyk, P. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9d11 · Cited by 11 · cited 1×
“58 Gaze orientation also plays an important role in both phosphenes location 59 and interpretability for mobility and visual tasks.”
Explainable machine learning predictions of perceptual sensitivity for retinal prostheses
Pogoncheff, G., Hu, Z., Rokem, A., & Beyeler, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad310f · Cited by 11
Haji Ghaffari, D., Akwaboah, A. D., Mirzakhalili, E., & Weiland, J. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3138297 · Cited by 10 · cited 1×
“Two studies were evaluated in a mouse model involving the transduction of a calcium indicator 94 and electrophysiological measurements 93 in RGCs to provide an objective measurement of their activity.”
Embracing the irregular: A patient-specific image processing strategy for visual prostheses
Kiral-Kornek, F. I., Savage, C. O., O'Sullivan-Greene, E., Burkitt, A. N., & Grayden, D. B. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610312 · Cited by 9
Explainable Machine Learning Predictions of Perceptual Sensitivity for Retinal Prostheses
Pogoncheff, G., Hu, Z., Rokem, A., & Beyeler, M. (2023) · doi:10.1101/2023.02.09.23285633 · Cited by 9 · cited 1×
“95 Another approach consisted in using human-in-the-loop optimization to improve the perceived image in a simulated prosthetic vision setting.”
Barry, M. P., Sadeghi, R., Towle, V. L., Stipp, K., Grant, P., Lane, F. J., Szlyk, J. P., Dagnelie, G., & Troyk, P. R. (2023) · Journal of Vision · doi:10.1167/jov.23.11.35 · Cited by 8 · cited 1×
“46 47–49 Despite these developments, there are no commercially available RCP devices to date.”
An actor-model framework for visual sensory encoding
Leong, F., Rahmani, B., Psaltis, D., Moser, C., & Ghezzi, D. (2024) · Nature Communications · doi:10.1038/s41467-024-45105-5 · Cited by 8 · cited 1×
“98 High-resolution images were projected into mouse retinas with a multielectrode array that detected neural spikes from RGCs in response Apart from improving phosphene shapes and predicting electrode malfunctioning, AI and machine learning might also be applied to other challenging tasks in the…”
de Ruyter van Steveninck, J., Nipshagen, M., van Gerven, M., Güçlü, U., Güçlüturk, Y., & van Wezel, R. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad357d · Cited by 8 · cited 1×
“60 These and certain unexplained variability factors represent a significant bottleneck for optimal stimulation with cortical prostheses.”
Going beyond vision to improve bionic vision
Li, W. H., Tang, T. J. J., & Lui, W. L. D. (2013) · 2013 IEEE International Conference on Image Processing · doi:10.1109/icip.2013.6738320 · Cited by 7 · cited 1×
“Of these, 14 relied on highly simplified representations using symmetrical phosphenes.”
Elnabawy, R. H., Abdennadher, S., Hellwich, O., & Eldawlatly, S. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-01059-7 · Cited by 6 · cited 1×
“85,86 Only one out of the 15 feature engineering studies has been implemented in human real prosthetic vision settings 77 with a suprachoroidal device.”
A Deep Learning-based in silico Framework for Optimization on Retinal Prosthetic Stimulation
Wu, Y., Karetić, I., Stegmaier, J., Walter, P., & Merhof, D. (2023) · 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340288 · Cited by 6 · cited 1×
“Of the five end-to-end studies that we identified, two relied on auto-encoding strategies, 88,91 where the task to be learnt is reconstructing an original image, and three entailed reinforcement learning approaches, 87,89,90 for which the scope of learned tasks is wider.”
Evaluating Deep Human-in-the-Loop Optimization for Retinal Implants Using Sighted Participants
Schoinas, E., Rastogi, A., Carter, A., Granley, J., & Beyeler, M. J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253762 · Cited by 5
Deep Learning--Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · arXiv · doi:10.48550/arxiv.2102.00297 · Cited by 4
Assessing visual acuity in visual prostheses through a virtual-reality systemPreprint
Sanchez-Garcia, M., Ruiz, R. M., Martínez-Cantín, R., Guerrero, J. J., & Fernandez-Jover, E. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2205.10395 · Cited by 4 · cited 1×
“We 50–54”
PVGAN: a generative adversarial network for object simplification in prosthetic vision
Elnabawy, R. H., Abdennadher, S., Hellwich, O., & Eldawlatly, S. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8acf · Cited by 3 · cited 3×
“86 Among the 14-feature engineering-based studies identified in our literature search, the most common feature type used for saliency map extraction was image contours, which provide salient spatial information about the environment.”
Self-Attention Based Vision Processing for Prosthetic Vision
White, J., Ruiz-Serra, J., Petrie, S., Kameneva, T., & McCarthy, C. (2023) · 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341053 · Cited by 3 · cited 1×
“Of the five end-to-end studies that we identified, two relied on auto-encoding strategies, 88,91 where the task to be learnt is reconstructing an original image, and three entailed reinforcement learning approaches, 87,89,90 for which the scope of learned tasks is wider.”
Evaluating Deep Human-in-the-Loop Optimization for Retinal Implants Using Sighted Participants
Schoinas, E., Rastogi, A., Carter, A., Granley, J., & Beyeler, M. (2025) · arXiv · doi:10.48550/arxiv.2502.00177 · Cited by 3 · cited 3×
“96,99 This approach allowed inclusion of patient’s preferences for stimulation parameters optimization and was proposed in two studies, one using virtual patients 96 and one using real sighted patients under SPV. 99 This approach might allow simultaneous optimization of the saliency extraction and the phosphenes consi…”
Chen, Y., Fu, J., Chu, D., Li, R., & Xie, Y. (2017) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2016-0049 · Cited by 2
Kartha, A., Sadeghi, R., Swanson, T., et al. (2023) · Journal of Vision · doi:10.1167/jov.23.11.55 · Cited by 1
Research works printed but not linked: 5
- Tassicker, 1956, Br J Physiol Opt, 13, 102
- Barry, 2023, Invest Ophthalmol Vis Sci, 64, 2842
- Huo, 2023, Invest Ophthalmol Vis Sci, 64, 5518
- Diaz, 2023, Invest Ophthalmol Vis Sci, 64, 5519
- Sahel, 2013, Invest Ophthalmol Vis Sci, 54, 1389
Cited by
Kim, S., Shim, H., & Im, M. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.202501360 · Cited by 2
Aniorte, A., Gea, M., Garrigós, J., Martínez, J. J., & Ferrández, J. M. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-27314-7_38
Metadata
- Authors
- Sarbout, I., Gungor, A., Ounissi, M., Zaher, S., Ptito, M., Kupers, R., Racoceanu, D., & Milea, D.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Hôpital Rothschild (FR)
- Montreal Neurological Institute and Hospital (CA)
- UCLouvain (BE)
- Venue
- Eye and Brain
- Publisher
- Informa UK Limited
- Published
- 2025-08
- Volume
- Volume 17
- Issue
- 6
- Pages
- 95-113
- ISSN
- 1179-2744 (ISSN-L)
- PMC
- PMC12405713
- OpenAlex
- W4413808600
- Semantic Scholar
- c89d2d9273048c906ce8cb086272f4b2226b720c
- Cited by
- 3
- References
- 101
- Citations by year
- 2026: 3
- FWCI
- 0.36
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Eye and Brain (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by-nc)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by-nc)
- HAL (submittedVersion, other-oa)
- Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- retinal prosthesis, artificial intelligence, artificial neural networks, phosphenes, electrical stimulation, visual acuity, simulated prosthetic vision, blind patients
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.