The DOI matches its Crossref record; 215 of the 232 references it cites were found in a registry or an index.
Retinal stimulation strategies to restore vision: Fundamentals and systems
Open accessAbstract
Retinal degeneration, a leading cause of blindness worldwide, is primarily characterized by the dysfunctional/degenerated photoreceptors that impair the ability of the retina to detect light. Our group and others have shown that bioelectronic retinal implants restore useful visual input to those who have been blind for decades. This unprecedented approach of restoring sight demonstrates that patients can adapt to new visual input, and thereby opens up opportunities to not only improve this technology but also develop alternative retinal stimulation approaches. These future improvements or new technologies could have the potential of selectively stimulating specific cell classes in the inner retina, leading to improved visual resolution and color vision. In this review we will detail the progress of bioelectronic retinal implants and future devices in this genre as well as discuss other technologies such as optogenetics, chemical photoswitches, and ultrasound stimulation. We will discuss the principles, biological aspects, technology development, current status, clinical outcomes/prospects, and challenges for each approach. The review will cover functional imaging documented cortical responses to retinal stimulation in blind patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subretinal prostheses are typically small in size, since large subretinal implants might encounter considerable difficulty in the surgical placement and represent a high risk of retinal detachment [32].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [32]
Citations
Cites
Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69740-7 · Cited by 2,924
Prevalence of Age-Related Macular Degeneration in the United States
The Eye Diseases Prevalence Research Group* (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.564 · Cited by 2,783
Intravitreal aflibercept (VEGF trap-eye) in wet age-related macular degeneration
Heier, J. S., Brown, D. M., Chong, V., Korobelnik, J.-F., Kaiser, P. K., Nguyen, Q. D., Kirchhof, B., Ho, A., Ogura, Y., Yancopoulos, G. D., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.09.006 · Cited by 2,485
Independent optical excitation of distinct neural populations
Klapoetke, N. C., Murata, Y., Kim, S. S., Pulver, S. R., Birdsey-Benson, A., Cho, Y. K., Morimoto, T. K., Chuong, A. S., Carpenter, E. J., Tian, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2836 · Cited by 2,344
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Azobenzene photoswitches for biomolecules
Beharry, A. A., & Woolley, G. A. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15023e · Cited by 1,884
Schwartz, S. D., Regillo, C. D., Lam, B. L., Eliott, D., Rosenfeld, P. J., Gregori, N. Z., Hubschman, J.-P., Davis, J. L., Heilwell, G., Spirn, M., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61376-3 · Cited by 1,327
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Molecular and Cellular Approaches for Diversifying and Extending Optogenetics
Gradinaru, V., Zhang, F., Ramakrishnan, C., Mattis, J., Prakash, R., Diester, I., Goshen, I., Thompson, K. R., & Deisseroth, K. A. (2010) · Cell · doi:10.1016/j.cell.2010.02.037 · Cited by 1,040
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A. J., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 1,008
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A. D., Baldwin, N. G., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 958
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
ReaChR: a red-shifted variant of channelrhodopsin enables deep transcranial optogenetic excitation
Lin, J. Y., Knutsen, P. M., Muller, A., Kleinfeld, D., & Tsien, R. Y. (2013) · Nature Neuroscience · doi:10.1038/nn.3502 · Cited by 858
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationTranslational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Next-Generation Optical Technologies for Illuminating Genetically Targeted Brain Circuits
Deisseroth, K. A., Feng, G., Majewska, A. K., Miesenböck, G., Ting, A. Y., & Schnitzer, M. J. (2006) · Journal of Neuroscience · doi:10.1523/jneurosci.3863-06.2006 · Cited by 808
Bi, A., Cui, J., Ma, Y.-P., Olshevskaya, E. V., Pu, M., Dizhoor, A. M., & Pan, Z. (2006) · Neuron · doi:10.1016/j.neuron.2006.02.026 · Cited by 790
Gunaydin, L. A., Yizhar, O., Berndt, A., Sohal, V. S., Deisseroth, K., & Hegemann, P. (2010) · Nature Neuroscience · doi:10.1038/nn.2495 · Cited by 757
Dalkara, D., Byrne, L. C., Klimczak, R. R., Visel, M., Yin, L., Merigan, W. H., Flannery, J. G., & Schaffer, D. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005708 · Cited by 734 · cited 1×
“An important area in the development of improved AAV vectors is the search for more efficient, immunologically tolerable serotypes (Cronin et al., 2014; Dalkara et al., 2013; Zinn et al., 2015) and cell type specific promoters (Cronin et al.”
Characterization of Engineered Channelrhodopsin Variants with Improved Properties and Kinetics
Lin, J. Y., Lin, M. Z., Steinbach, P. A., & Tsien, R. Y. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.11.034 · Cited by 720
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 708
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationAge-Related Macular Degeneration Is the Leading Cause of Blindness . . .
Bressler, N. M. (2004) · JAMA · doi:10.1001/jama.291.15.1900 · Cited by 687
Channelrhodopsin-2 and optical control of excitable cells
Zhang, F., Wang, L., Boyden, E. S., & Deisseroth, K. A. (2006) · Nature Methods · doi:10.1038/nmeth936 · Cited by 683
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Genetic Reactivation of Cone Photoreceptors Restores Visual Responses in Retinitis Pigmentosa
Busskamp, V., Duebel, J., Bálya, D., Fradot, M., Viney, T. J., Siegert, S., Groner, A. C., Cabuy, E., Forster, V., Seeliger, M. W., et al. (2010) · Science · doi:10.1126/science.1190897 · Cited by 660
Self-citationPreservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationLagali, P. S., Bálya, D., Awatramani, G. B., Münch, T. A., Kim, D. S., Busskamp, V., Cepko, C. L., & Roska, B. (2008) · Nature Neuroscience · doi:10.1038/nn.2117 · Cited by 580
Self-citationUnknown (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(97)00012-8 · Cited by 570
RICHER, S. P., Stiles, W. R., Statkute, L., Pulido, J. S., Frankowski, J., Rudy, D., Pei, K. Y., Tsipursky, M. S., & Nyland, J. (2004) · Optometry · doi:10.1016/s1529-1839(04)70049-4 · Cited by 563
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 512
Rate Coding Versus Temporal Order Coding: What the Retinal Ganglion Cells Tell the Visual Cortex
Rullen, R. V., & Thorpe, S. J. (2001) · Neural Computation · doi:10.1162/08997660152002852 · Cited by 493
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S. B. B., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 480
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Ultra light-sensitive and fast neuronal activation with the Ca2+-permeable channelrhodopsin CatCh
Kleinlogel, S., Feldbauer, K., Dempski, R. E., Fotis, H., Wood, P. G., Bamann, C., & Bamberg, E. (2011) · Nature Neuroscience · doi:10.1038/nn.2776 · Cited by 477
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Microsaccades Counteract Visual Fading during Fixation
Martínez‐Conde, S., Macknik, S. L., Troncoso, X. G., & Dyar, T. A. (2006) · Neuron · doi:10.1016/j.neuron.2005.11.033 · Cited by 472
Mutations in a human homologue of Drosophila crumbs cause retinitis pigmentosa (RP12)
den Hollander, A. I., ten Brink, J. B., de Kok, Y. J. M., Soest, S. V., van den Born, L. I., van Driel, M. A., van de Pol, D. J. R., Payne, A. M., Bhattacharya, S. S., Kellner, U., et al. (1999) · Nature Genetics · doi:10.1038/13848 · Cited by 468
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G. A., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 460
Dobelle, W. H., Mladejovsky, M. G., & Girvin, J. P. (1974) · Science · doi:10.1126/science.183.4123.440 · Cited by 440
Wells, J. A., Wroblewski, J. J., Keen, T. J., Inglehearn, C. F., Jubb, C., Eckstein, A. K., Jay, M., Arden, G. B., Bhattacharya, S. S., Fitzke, F. W., et al. (1993) · Nature Genetics · doi:10.1038/ng0393-213 · Cited by 438
Meister, M., & Berry, M. J. (1999) · Neuron · doi:10.1016/s0896-6273(00)80700-x · Cited by 431
Age-Related Macular Degeneration
Fine, S. L., Berger, J. W., Maguire, M. G., & Ho, A. C. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420707 · Cited by 424
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
Subretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Self-citationInformation Processing in the Primate Retina: Circuitry and Coding
Field, G. D., & Chichilnisky, E. J. (2007) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.30.051606.094252 · Cited by 378
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Self-citationda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Self-citationThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 342
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T. I., Mathieson, K., Huie, P., Harris, J. S., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 341
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. A. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 330
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 327
Age‐related Macular Degeneration (AMD)
(2008) · Springer eBooks · doi:10.1007/978-3-540-38918-7_5059 · Cited by 322
Photoreceptor degeneration and dysfunction in aging and age-related maculopathy
Jackson, G. R., Owsley, C., & Curcio, C. A. (2002) · Ageing Research Reviews · doi:10.1016/s1568-1637(02)00007-7 · Cited by 317
Some Quantitative Methods for the Study of Spontaneous Activity of Single Neurons
Rodieck, R. W., Kiang, N. Y.-S., & Gerstein, G. L. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86860-x · Cited by 312
In Silico Reconstruction of the Viral Evolutionary Lineage Yields a Potent Gene Therapy Vector
Zinn, E., Pacouret, S., Khaychuk, V., Turunen, H. T., Carvalho, L. S., Andres-Mateos, E., Shah, S., Shelke, R., Maurer, A. C., Plovie, E., et al. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.07.019 · Cited by 310
Restoration of visual function in retinal degeneration mice by ectopic expression of melanopsin
Lin, B., Koizumi, A., Tanaka, N., Panda, S., & Masland, R. H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806114105 · Cited by 302
Brief, Noninjurious Electric Waveform for Stimulation of the Brain
Lilly, J. C., Hughes, J. R., Alvord, E. C., & Galkin, T. W. (1955) · Science · doi:10.1126/science.121.3144.468 · Cited by 287
Reorganization of Visual Processing in Macular Degeneration
Baker, C. I., Eli Peli, A., Knouf, N. A., & Kanwisher, N. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.3476-04.2005 · Cited by 285
Doroudchi, M. M., Greenberg, K. P., Liu, J., Silka, K. A., Boyden, E. S., Lockridge, J. A., Arman, A. C., Ramesh, J., Boye, S. L., Boye, S. L., et al. (2011) · Molecular Therapy · doi:10.1038/mt.2011.69 · Cited by 282
Fariss, R. N., Li, Z.-Y., & Milam, A. H. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00401-8 · Cited by 273
Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind
Ho, A. C., Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Handa, J. T., Barale, P. O., Sahel, J., Stanga, P. E., Hafezi, F., et al. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.032 · Cited by 262
Self-citationSpare the rods, save the cones in aging and age-related maculopathy.
Curcio, C. A., Owsley, C. J., & Jackson, G. R. (2000) · PubMed · Cited by 261
Beltran, W. A., Cideciyan, A. V., Lewin, A. S., Iwabe, S., Khanna, H., Sumaroka, A., Chiodo, V. A., Fajardo, D. S., Román, A. J., Deng, W.-T., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1118847109 · Cited by 260
Singh, M. S., Issa, P. C., Butler, R., Martin, C. J., Lipinski, D. M., Sekaran, S., Barnard, A. R., & MacLaren, R. E. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119416110 · Cited by 258
Marconi, B. (2001) · Cerebral Cortex · doi:10.1093/cercor/11.6.513 · Cited by 257
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255
Optogenetic therapy for retinitis pigmentosa
Busskamp, V., Picaud, S. A., Sahel, J., & Roska, B. (2011) · Gene Therapy · doi:10.1038/gt.2011.155 · Cited by 247
Self-citationRod photoreceptor neurite sprouting in retinitis pigmentosa
Li, Z., Kljavin, I., & Milam, A. (1995) · Journal of Neuroscience · doi:10.1523/jneurosci.15-08-05429.1995 · Cited by 245
Kienzler, M. A., Reiner, A., Trautman, E. P., Yoo, S., Trauner, D. H., & Isacoff, E. Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408104w · Cited by 238
Multi-site optical excitation using ChR2 and micro-LED array
Grossman, N., Poher, V., Grubb, M. S., Kennedy, G. T., Nikolić, K., McGovern, B., Palmini, R. B., Gong, Z., Drakakis, E. M., Neil, M. A. A., et al. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016004 · Cited by 238
Photochemical Restoration of Visual Responses in Blind Mice
Polosukhina, A., Litt, J., Tochitsky, I., Nemargut, J. P., Sychev, Y., Kouchkovsky, I. D., Huang, T., Borges, K., Trauner, D. H., Gelder, R. N. V., et al. (2012) · Neuron · doi:10.1016/j.neuron.2012.05.022 · Cited by 238
Visual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa
Yanai, D., Weiland, J. D., Mahadevappa, M., Greenberg, R. J., Fine, I., & Humayun, M. S. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.027 · Cited by 233
Self-citationPrimate retina: cell types, circuits and color opponency
Dacey, D. M. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00013-5 · Cited by 233
Precise Neural Stimulation in the Retina Using Focused Ultrasound
Menz, M. D., Oralkan, Ö., Khuri-Yakub, B. T., & Baccus, S. A. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.3521-12.2013 · Cited by 230
Preservation of ganglion cell layer neurons in age-related macular degeneration.
Medeiros, N. E., & Curcio, C. A. (2001) · PubMed · Cited by 224
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216
A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
Fried, S. I., Hsueh, H.-A., & Werblin, F. S. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00849.2005 · Cited by 212
van Wyk, M., Pielecka-Fortuna, J., Löwel, S., & Kleinlogel, S. (2015) · PLoS Biology · doi:10.1371/journal.pbio.1002143 · Cited by 211
Retinal prosthetic strategy with the capacity to restore normal vision
Nirenberg, S., & Pandarinath, C. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207035109 · Cited by 207
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Self-citationSimulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Macé, É., Caplette, R., Marre, O., Sengupta, A., Chaffiol, A., Barbe, P., Desrosiers, M., Bamberg, E., Sahel, J., Picaud, S. A., et al. (2014) · Molecular Therapy · doi:10.1038/mt.2014.154 · Cited by 197
Tochitsky, I., Polosukhina, A., Degtyar, V. E., Gallerani, N., Smith, C. M., Friedman, A. R., Gelder, R. N. V., Trauner, D. H., Kaufer, D., & Krämer, R. (2014) · Neuron · doi:10.1016/j.neuron.2014.01.003 · Cited by 196
Retinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 196
Self-citationHigh-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.5138-07.2008 · Cited by 195
Rakoczy, E. P., Lai, C.-M., Magno, A. L., Wikstrom, M. E., French, M. A., Pierce, C. M., Schwartz, S. D., Blumenkranz, M. S., Chalberg, T. W., Degli-Esposti, M. A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00345-1 · Cited by 189
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189
Perceptual thresholds and electrode impedance in three retinal prosthesis subjects
Mahadevappa, M., Weiland, J. D., Yanai, D., Fine, I., Greenberg, R. J., & Humayun, M. S. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848687 · Cited by 187
Self-citationWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Self-citationRestoration of vision with ectopic expression of human rod opsin
Cehajic-Kapetanovic, J., Eleftheriou, C., Allen, A. E., Milosavljevic, N., Pienaar, A., Bedford, R., Davis, K. E., Bishop, P. N., & Lucas, R. J. (2015) · Current Biology · doi:10.1016/j.cub.2015.07.029 · Cited by 184
Zhu, J., & Yang, J. (2003) · doi:10.1109/afgr.2002.1004144 · Cited by 184
Cronin, T., Vandenberghe, L. H., Hantz, P., Jüttner, J., Reimann, A., Kacsó, Á., Huckfeldt, R. M., Busskamp, V., Kohler, H., Lagali, P. S., et al. (2014) · EMBO Molecular Medicine · doi:10.15252/emmm.201404077 · Cited by 184
Self-citationWeiland, J. D., & Humayun, M. S. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922589 · Cited by 179
Self-citationApplication of focused ultrasound for the stimulation of neural structures
Gavrilov, L. R., Tsirulnikov, E. M., & Davies, I. A. I. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(96)83782-3 · Cited by 177
Reading speed with a pixelized vision system
Cha, K., Boman, D. K., Horch, K., & Normann, R. A. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000673 · Cited by 173
Visually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D. V., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 164
Self-citationNanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163 · cited 3×
“2) Phosphene brightness increased as a function of stimulation amplitude and frequency but phosphene size exhibitedmuch higher dependence on the amplitude than frequency (de Balthasar et al., 2008; Nanduri et al., 2012).”
Self-citationStimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wächtler, T. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 162
Roessler, G. F., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B. A. E., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., et al. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2752 · Cited by 161
Haupts, U. M., Tittor, J., Bamberg, E., & Oesterhelt, D. (1997) · Biochemistry · doi:10.1021/bi962014g · Cited by 161
MORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158
Self-citationWilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Selective Activation of Neuronal Targets With Sinusoidal Electric Stimulation
Freeman, D. K., Eddington, D. K., Rizzo, J. F., & Fried, S. I. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00551.2010 · Cited by 154
Spatiotemporal frequency responses of cat retinal ganglion cells.
Frishman, L. J., Freeman, A. W., Troy, J. B., Schweitzer‐Tong, D. E., & Enroth‐Cugell, C. (1987) · The Journal of General Physiology · doi:10.1085/jgp.89.4.599 · Cited by 154
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Self-citationFeasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149
Boinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
Photovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G. A., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 142
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Thyagarajan, S., van Wyk, M., Lehmann, K., Löwel, S., Feng, G., & Wässle, H. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.4417-09.2010 · Cited by 137
Real and virtual mobility performance in simulated prosthetic vision
Dagnelie, G., Keane, P. A., Narla, V., Yang, L., Weiland, J. D., & Humayun, M. S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s11 · Cited by 136
Self-citationZhang, Y., Ivanova, E., Bi, A., & Pan, Z. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.0184-09.2009 · Cited by 132
Brummer, S. B., & Turner, M. J. (1975) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(75)80002-x · Cited by 132
Beck, H., Boden, W. E., Patibandla, S., Kireyev, D., Gupta, V., Campagna, F., CAIN, M. E., & Marine, J. E. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.04.043 · Cited by 128
Responses of ganglion cells to repetitive electrical stimulation of the retina
Jensen, R. J., & Rizzo, J. F. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s01 · Cited by 121
THE USE OF ELECTRICAL DEVICES FOR THE TREATMENT OF BLADDER DYSFUNCTION: A REVIEW OF METHODS
van BALKEN, M. R., VERGUNST, H., & BEMELMANS, B. L. H. (2004) · Journal of Urology · doi:10.1097/01.ju.0000134418.21959.98 · Cited by 121
Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode
Jensen, R. J., & Rizzo, J. F. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.01.012 · Cited by 120
Holographic optogenetic stimulation of patterned neuronal activity for vision restoration
Reutsky, I., Golan, L., Farah, N., Schejter, A., Tsur, L., Brosh, I., & Shoham, S. (2013) · Nature Communications · doi:10.1038/ncomms2500 · Cited by 119
Dilks, D. D., Baker, C. I., Eli Peli, A., & Kanwisher, N. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.5258-08.2009 · Cited by 117
Sommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Eye–hand coordination in goal-directed aiming
Binsted, G., Chua, R., Helsen, W. F., & Elliott, D. (2001) · Human Movement Science · doi:10.1016/s0167-9457(01)00068-9 · Cited by 115
REVIEW ■ : Prospects for a Visual Prosthesis
Rizzo, J. F., & Wyatt, J. L. (1997) · The Neuroscientist · doi:10.1177/107385849700300413 · Cited by 114
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Experimental Nondestructive Electrical Stimulation of the Brain and Spinal Cord
Mortimer, J. T., Shealy, C. N., & Wheeler, C. (1970) · Journal of neurosurgery · doi:10.3171/jns.1970.32.5.0553 · Cited by 113
Evaluation of AAV-Mediated Expression of Chop2-GFP in the Marmoset Retina
Ivanova, E., Hwang, G.-S., Pan, Z., & Troilo, D. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5389 · Cited by 112
Modeling Study of the Light Stimulation of a Neuron Cell With Channelrhodopsin-2 Mutants
Grossman, N., Nikolić, K., Toumazou, C., & Degenaar, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2114883 · Cited by 112
Szlyk, J. P. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150055009 · Cited by 111
AnIn VitroModel of a Retinal Prosthesis
Ahuja, A. K., Behrend, M. R., Kuroda, M., Humayun, M. S., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919126 · Cited by 111
Self-citationResponses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/003 · Cited by 110
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107
Self-citationEffect of shape and coating of a subretinal prosthesis on its integration with the retina
Butterwick, A., Huie, P., Jones, B. W., Marc, R. E., Marmor, M. F., & Palanker, D. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.09.018 · Cited by 107
A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses
Kelly, S. K., Shire, D. B., Chen, J., Doyle, P., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Behan, S., Theogarajan, L. S., Wyatt, J. L., et al. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2165713 · Cited by 107
Resolution of the epiretinal prosthesis is not limited by electrode size
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2140132 · Cited by 102
Self-citationGetting signals into the brain: visual prosthetics through thalamic microstimulation
Pezaris, J. S., & Eskandar, E. N. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0986 · Cited by 98
Sekirnjak, C., Hulse, C., Jepson, L. H., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00663.2009 · Cited by 98
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
Visual resolution with retinal implants estimated from recordings in cat visual cortex
Eckhorn, R., Wilms, M., Schanze, T., Eger, M., Hesse, L., Eysel, U. T., Kisvárday, Z. F., Zrenner, E., Gekeler, F., Schwahn, H., et al. (2006) · Vision Research · doi:10.1016/j.visres.2006.01.034 · Cited by 94
Stem Cell-Based Therapeutic Applications in Retinal Degenerative Diseases
Huang, Y., Enzmann, V., & Ildstad, S. T. (2010) · Stem Cell Reviews and Reports · doi:10.1007/s12015-010-9192-8 · Cited by 94
Tunable retina encoders for retina implants: why and how
Eckmiller, R., Neumann, D., & Baruth, O. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/011 · Cited by 88
Menzel-Severing, J., Laube, T., Brockmann, C., Bornfeld, N., Mokwa, W., Mazinani, B. A. E., Walter, P., & Roessler, G. F. (2012) · Eye · doi:10.1038/eye.2012.35 · Cited by 83
Suesserman, M. F., Spelman, F. A., & Rubinstein, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81558 · Cited by 83
Lilly, J. C., Austin, G., & Chambers, W. W. (1952) · Journal of Neurophysiology · doi:10.1152/jn.1952.15.4.319 · Cited by 82
Inner Retinal Mechanisms Engaged by Retinal Electrical Stimulation
Margalit, E., & Thoreson, W. B. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1093 · Cited by 81
Optogenetic approaches to retinal prosthesis
Barrett, J. M., Palmini, R. B., & Degenaar, P. A. (2014) · Visual Neuroscience · doi:10.1017/s0952523814000212 · Cited by 81
Multiple components of ganglion cell desensitization in response to prosthetic stimulation
Freeman, D. K., & Fried, S. I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016008 · Cited by 80
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Lorach, H., Goetz, G. A., Mandel, Y., Lei, X., Kamins, T. I., Mathieson, K., Huie, P., Dalal, R., Harris, J. S., & Palanker, D. (2014) · Vision Research · doi:10.1016/j.visres.2014.09.007 · Cited by 78
Subretinal implantation of semiconductor-based photodiodes: progress and challenges.
Peachey, N. S., & Chow, A. Y. (1999) · PubMed · Cited by 77
Potts, A. M., & Inoue, J. (1969) · PubMed · Cited by 75
Retinal prosthesis phosphene shape analysis
Nanduri, D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., & Weiland, J. D. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649524 · Cited by 74
Self-citationFunctional Outcome in Subretinal Electronic Implants Depends on Foveal Eccentricity
Štingl, K., Bartz‐Schmidt, K. U., Gekeler, F., Kusnyerik, Á., Sachs, H. G., & Zrenner, E. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12835 · Cited by 73
Yamauchi, Y., Franco, L. M., Jackson, D., Naber, J. F., Ziv, R. O., Rizzo, J. F., Kaplan, H. J., & Enzmann, V. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/007 · Cited by 71
High-Fidelity Reproduction of Spatiotemporal Visual Signals for Retinal Prosthesis
Jepson, L. H., Hottowy, P., Weiner, G., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · Neuron · doi:10.1016/j.neuron.2014.04.044 · Cited by 71
Current and future prospects for optoelectronic retinal prostheses
Dowling, J. (2008) · Eye · doi:10.1038/eye.2008.385 · Cited by 69
Acute electrical stimulation of the human retina with an epiretinal electrode array
Keserü, M., Feucht, M., Bornfeld, N., Laube, T., Walter, P., Rößler, G., Velikay‐Parel, M., Hornig, R., & Richard, G. W. (2011) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2011.02288.x · Cited by 69
Improved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68
Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I
Lan, Y., Falabella, P., Christopher, P., Wuyyuru, V., Dorn, J. D., Schor, P., Greenberg, R. J., Weiland, J. D., & Humayun, M. S. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.08.008 · Cited by 67
Self-citationRobust photoregulation of GABAA receptors by allosteric modulation with a propofol analogue
Lan, Y., Pawłowski, M., Dellal, S. S., Xie, A., Feng, F., Otis, T. S., Bruzik, K. S., Qian, H., & Pepperberg, D. R. (2012) · Nature Communications · doi:10.1038/ncomms2094 · Cited by 67
Naor, O., Hertzberg, Y., Zemel, E., Kimmel, E., & Shoham, S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026006 · Cited by 66
Cathelicidin LL-37 and HSV-1 Corneal Infection: Peptide Versus Gene Therapy
Lee, C.-J., Buznyk, O., Kuffová, L., Rajendran, V., Forrester, J. V., Phopase, J., Islam, M. M., Skog, M., Ahlqvist, J., & Griffith, M. (2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.3.4 · Cited by 65
Electrical stimulation in normal and retinal degeneration (rd1) isolated mouse retina
O’Hearn, T. M., Sadda, S. R., Weiland, J. D., Maia, M., Margalit, E., & Humayun, M. S. (2006) · Vision Research · doi:10.1016/j.visres.2006.03.031 · Cited by 65
Self-citationDjilas, M., Olès, C., Lorach, H., Bendali, A., Dégardin, J., Dubus, É., Lissorgues, G., Rousseau, L., Benosman, R. B., Ieng, S.-H., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046020 · Cited by 65
Comparison of Electrical Stimulation Thresholds in Normal and Retinal Degenerated Mouse Retina
Suzuki, S., Humayun, M. S., Weiland, J. D., Chen, S., Margalit, E., Piyathaisere, D. V., & de Juan, E. (2004) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-004-0084-9 · Cited by 60
Self-citationChow, A. Y., Bittner, A. K., & Pardue, M. T. (2010) · PubMed Central · Cited by 60
Heating of the eye by a retinal prosthesis: modeling, cadaver and in vivo study
Opie, N. L., Burkitt, A. N., Meffin, H., & Grayden, D. B. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2171961 · Cited by 59
Tsai, D., Chen, S. C., Protti, D. A., Morley, J. W., Suaning, G. J., & Lovell, N. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0053357 · Cited by 56
Cell Types, Circuits, Computation
da Silveira, R. A., & Roska, B. (2011) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2011.05.007 · Cited by 56
Self-citationInterphase gap as a means to reduce electrical stimulation thresholds for epiretinal prostheses
Weitz, A. C., Behrend, M. R., Ahuja, A., Christopher, P., Wei, J., Wuyyuru, V., Patel, U. K., Greenberg, R. J., Humayun, M. S., Chow, R. H.-P., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016007 · Cited by 51
Self-citationLorach, H., Benosman, R. B., Marre, O., Ieng, S.-H., Sahel, J., & Picaud, S. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066004 · Cited by 49
Chan, L. L.-H., Lee, E.-J., Humayun, M. S., & Weiland, J. D. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00619.2010 · Cited by 49
Self-citationSafety and efficacy of subretinal visual implants in humans: methodological aspects
Štingl, K., Bach, M., Bartz‐Schmidt, K. U., Braun, A., Bruckmann, A. R., Gekeler, F., Greppmaier, U., Hörtdörfer, G., Kusnyerik, Á., Peters, T. M., et al. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00816.x · Cited by 48
Parver, L. M. (1983) · Archives of Ophthalmology · doi:10.1001/archopht.1983.01040020606021 · Cited by 48
Numata, T., Murakami, T., Kawashima, F., Morone, N., Heuser, J. E., Takano, Y., Ohkubo, K., Fukuzumi, S., Mori, Y., & Imahori, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3007275 · Cited by 46
Daiger, S. P., Bowne, S. J., Sullivan, L. S., Blanton, S. H., Weinstock, G. M., Koboldt, D. C., Fulton, R. S., Larsen, D., Humphries, P., Humphries, M. M., et al. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-1-4614-3209-8_16 · Cited by 44
Chronic Implantation of Newly Developed Suprachoroidal-Transretinal Stimulation Prosthesis in Dogs
Morimoto, T., Kamei, M., Nishida, K., Sakaguchi, H., Kanda, H., Ikuno, Y., Kishima, H., Maruo, T., Konoma, K., Ozawa, M., et al. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6971 · Cited by 41
Toward a wide-field retinal prosthesis
Ameri, H., Ratanapakorn, T., Ufer, S., Eckhardt, H., Humayun, M. S., & Weiland, J. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035002 · Cited by 40
Self-citationWilms, M., Eger, M., Schanze, T., & ECKHORNdagger, R. (2003) · Visual Neuroscience · doi:10.1017/s0952523803205083 · Cited by 40
Luo, Y. H.-L., Zhong, J., & da Cruz, L. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2912-z · Cited by 39
Habib, A. G., Cameron, M. A., Suaning, G. J., Lovell, N. H., & Morley, J. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036013 · Cited by 38
Prosthetic vision: devices, patient outcomes and retinal research
Hadjinicolaou, A. E., Hamish Meffin, A., Maturana, M. I., Cloherty, S. L., & Ibbotson, M. R. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12342 · Cited by 38
Promises of stem cell therapy for retinal degenerative diseases
Wong, I. Y.-H., Poon, M.-W., Pang, R. T.-W., Lian, Q., & Wong, D. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1764-z · Cited by 37
Preservation of retinotopic map in retinal degeneration
Xie, J., Wang, G., Yow, L., Humayun, M. S., Weiland, J. D., Cela, C. J., Jadvar, H., Lazzi, G., Dhrami‐Gavazi, E., & Tsang, S. H. (2012) · Experimental Eye Research · doi:10.1016/j.exer.2012.03.017 · Cited by 34
Self-citationDevelopments on the Boston 256-channel retinal implant
Kelly, S. K., Shire, D. B., Chen, J., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Ellersick, W. F., Krishnan, A., Behan, S., Wyatt, J. L., et al. (2013) · IEEE International Conference on Multimedia and Expo workshops · doi:10.1109/icmew.2013.6618445 · Cited by 33
Retinal safety of near infrared radiation in photovoltaic restoration of sight.
Lorach, H., Wang, J., Lee, D. Y., Dalal, R., Huie, P., & Palanker, D. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000013 · Cited by 33
Sailer, H., Shinoda, K., Blatsios, G., Köhler, K., Bondzio, L., Zrenner, E., & Gekeler, F. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-006-0513-1 · Cited by 31
Holographic display system for restoration of sight to the blind
Goetz, G. A., Mandel, Y., Manivanh, R. V., Palanker, D., & Čižmár, T. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056021 · Cited by 31
Optical coherence tomography imaging of retinal damage in real time under a stimulus electrode
Cohen, E. D., Agrawal, A., Connors, M., Hansen, B., Charkhkar, H., & Pfefer, J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056017 · Cited by 31
Parylene origami structure for intraocular implantation
Liu, Y., Park, J., Lang, R. J., Emami, A., Pellegrino, S., Humayun, M. S., & Tai, Y. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6627077 · Cited by 28
Self-citationRecognizing retinal ganglion cells in the dark
Richard, É., Goetz, G. A., & Chichilnisky, E. J. (2015) · neural information processing systems · Cited by 26
Wells, J. A., Wroblewski, J. J., Keen, T. J., Inglehearn, C. F., Jubb, C., Eckstein, A. K., Jay, M., Arden, G. B., Bhattacharya, S. S., Fitzke, F. W., et al. (1993) · Springer eBooks · doi:10.1007/978-1-4615-2974-3_6 · Cited by 25
Research works printed but not linked: 8
- Dacey, 2008, Physiology, morphology and spatial densities of identified ganglion cell, Ciba Found. Symp., 765, 12
- Luo, 2014, The use of Argus® II retinal prosthesis to identify common objects in blind subjects with outer retinal dystrophies, Investig. Ophthalmol. Vis. Sci., 55, 1834
- Milam, 1998, Histopathology of the human retina in retinitis pigmentosa, Prog. Retin. Eye Res., 17, 175
- Richard, 2007, Chronic epiretinal chip implant in blind patients with retinitis pigmentosa: long-term clinical results, Investig. Ophthalmol. Vis. Sci., 48, 666
- Stanga, 2011, Patients blinded by outer retinal dystrophies are able to perceive color using the ArgusTm II retinal prosthesis system, Investig. Ophthalmol. Vis. Sci., 52, 4949
- Stanga, 2012, Patients blinded by outer retinal dystrophies are able to perceive simultaneous colors using the Argus® II retinal prosthesis system, Investig. Ophthalmol. Vis. Sci., 53, 6952
- Yue, 2013, Potentiation of bipolar cell GABAA receptors by a photo-isomerizable compound, Investig. Ophthalmol. Vis. Sci., 54, 1761
- Zrenner, 2015, Oculomotor behavior of blind patients seeing with subretinal visual implant Alpha IMS, Investig. Ophthalmol. Vis. Sci., 56, 751
Cited by
Sorted by citations
Dias, M. F., Joo, K., Kemp, J. A., Fialho, S. L., Silva‐Cunha, A., Woo, S. J., & Kwon, Y. J. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.004 · Cited by 437
Microbial Rhodopsins: Diversity, Mechanisms, and Optogenetic Applications
Govorunova, E. G., Sineshchekov, O. A., Li, H., & Spudich, J. L. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-101910-144233 · Cited by 368
Neuroprotective strategies for retinal disease
Pardue, M. T., & Allen, R. S. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.02.002 · Cited by 237
Schneider, N., Sundaresan, Y., Gopalakrishnan, P., Beryozkin, A., Hanany, M., Levanon, E. Y., Banin, E., Ben‐Aroya, S., & Sharon, D. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101029 · Cited by 231
An update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223
Self-citation
Metadata
- Authors
- Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S.
- Affiliations
- University of Southern California (US)
- University of Basel (CH)
- Corresponding author
- Humayun, Mark S.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2016-07
- Volume
- 53
- Pages
- 21-47
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W2401981424
- Cited by
- 272
- References
- 232
- Citations by year
- 2026: 12 · 2025: 22 · 2024: 28 · 2023: 19 · 2022: 30 · 2021: 35 · 2020: 43 · 2019: 31 · 2018: 22 · 2017: 26 · 2016: 4
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Progress in Retinal and Eye Research (acceptedVersion)
- PubMed (publishedVersion)
- Funders
- W. M. Keck Foundation
- National Science Foundation (NSF) (CBET-1404089)
- Juliette RP Vision Foundation
- Guangdong Innovative and Entrepreneurial and Research Team Program (2013S046)
- Shenzhen Peacock Plan of China
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- retinal stimulation, retinal degeneration, blindness, photoreceptor degeneration, optogenetics, ultrasound stimulation, vision restoration, color vision, visual resolution
- MeSH terms
- Animals, Energy Metabolism, Humans, Retina, Retinal Degeneration, Vision, Ocular, Recovery of Function, Visual Prosthesis, Optogenetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review