The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Abstract
Digital health facilitated by wearable/portable electronics and big data analytics holds great potential in empowering patients with real‐time diagnostics tools and information. The detection of a majority of biomarkers at trace levels in body fluids using mobile health (mHealth) devices requires bioaffinity sensors that rely on “bioreceptors” for specific recognition. Portable point‐of‐care testing (POCT) bioaffinity sensors have demonstrated their broad utility for diverse applications ranging from health monitoring to disease diagnosis and management. In addition, flexible and stretchable electronics‐enabled wearable platforms have emerged in the past decade as an interesting approach in the ambulatory collection of real‐time data. Herein, the technological advancements of mHealth bioaffinity sensors evolved from laboratory assays to portable POCT devices, and to wearable electronics, are synthesized. The involved recognition events in the mHealth affinity biosensors enabled by bioreceptors (e.g., antibodies, DNAs, aptamers, and molecularly imprinted polymers) are discussed along with their transduction mechanisms (e.g., electrochemical and optical) and system‐level integration technologies. Finally, an outlook of the field is provided and key technological bottlenecks to overcome identified, in order to achieve a new sensing paradigm in wearable bioaffinity platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Self-citationELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Harold, D., Abraham, R., Hollingworth, P., Sims, R., Gerrish, A., Hamshere, M. L., Pahwa, J. S., Moskvina, V., Dowzell, K., Williams, A., et al. (2009) · Nature Genetics · doi:10.1038/ng.440 · Cited by 3,326
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Decher, G., Hong, J. D., & Schmitt, J. (1992) · Thin Solid Films · doi:10.1016/0040-6090(92)90417-a · Cited by 2,821
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Elevated C-reactive protein levels in overweight and obese adults
Visser, M. (1999) · JAMA · doi:10.1001/jama.282.22.2131 · Cited by 2,494
The MicroRNA Spectrum in 12 Body Fluids
Weber, J. A., Baxter, D. H., Zhang, S., Huang, D. Y., How Huang, K., Jen Lee, M., Galas, D. J., & Wang, K. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.147405 · Cited by 2,477
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Wulff, G. (1995) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199518121 · Cited by 2,373
Nanobodies: natural single-domain antibodies
Muyldermans, S. (2013) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-063011-092449 · Cited by 2,304
Regulation of the Hypothalamic‐Pituitary‐Adrenocortical Stress Response
Herman, J. P., McKlveen, J. M., Ghosal, S., Kopp, B., Wulsin, A., Makinson, R., Scheimann, J., & Myers, B. (2016) · Comprehensive Physiology · doi:10.1002/cphy.c150015 · Cited by 1,819
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Mechanisms of thyroid hormone action
Brent, G. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci60047 · Cited by 1,244
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Koczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Mobile Health Technology Evaluation
Kumar, S., Nilsen, W. J., Abernethy, A., Atienza, A., Patrick, K., Pavel, M., Riley, W. T., Shar, A., Spring, B., Spruijt-Metz, D., et al. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2013.03.017 · Cited by 900
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Self-citationBurnout, Perceived Stress, and Cortisol Responses to Awakening
Pruessner, J. C., Hellhammer, D. H., & Kirschbaum, C. (1999) · Psychosomatic Medicine · doi:10.1097/00006842-199903000-00012 · Cited by 822
The emerging field of mobile health
Steinhubl, S. R., Muse, E. D., & Topol, E. J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3487 · Cited by 822
Arican, O., Aral, M., Sasmaz, S., & Ciragil, P. (2005) · Mediators of Inflammation · doi:10.1155/mi.2005.273 · Cited by 805
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
You, C.-C., Miranda, O. R., Gider, B., Ghosh, P. S., Kim, I.-B., Erdogan, B., Krovi, S. A., Bunz, U. H. F., & Rotello, V. M. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.99 · Cited by 776
Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays
Zhao, W., Brook, M. A., & Li, Y. (2008) · ChemBioChem · doi:10.1002/cbic.200800282 · Cited by 768
Microfluidics-based diagnostics of infectious diseases in the developing world
Chin, C. D., Laksanasopin, T., Cheung, Y. K., Steinmiller, D., Linder, V., Parsa, H., Wang, J., Moore, H., Rouse, R., Umviligihozo, G., et al. (2011) · Nature Medicine · doi:10.1038/nm.2408 · Cited by 759
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Highly Skin‐Conformal Microhairy Sensor for Pulse Signal Amplification
Pang, C., Koo, J. H., Nguyen, A., Caves, J. M., Kim, M., Chortos, A., Kim, K., Wang, P. J., Tok, J. B. ‐., & Bao, Z. (2015) · Advanced Materials · doi:10.1002/adma.201403807 · Cited by 734
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
3D printed microfluidics for biological applications
Ho, C. M. B., Ng, S. H., Li, K. H. H., & Yoon, Y.-J. (2015) · Lab on a Chip · doi:10.1039/c5lc00685f · Cited by 704
Biosensing with surface plasmon resonance — how it all started
Liedberg, B., Nylander, C., & Lundström, I. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96965-2 · Cited by 684
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Variations of oral microbiota are associated with pancreatic diseases including pancreatic cancer
Farrell, J. J., Zhang, L., Zhou, H., Chia, D., Elashoff, D., Akin, D., Paster, B. J., Joshipura, K., & Wong, D. T. W. (2012) · Gut · doi:10.1136/gutjnl-2011-300784 · Cited by 662
Salivary Biomarkers: Toward Future Clinical and Diagnostic Utilities
Yoshizawa, J. M., Schafer, C. A., Schafer, J. J., Farrell, J. J., Paster, B. J., & Wong, D. T. W. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00021-13 · Cited by 656
Hajian, R., Balderston, S., Tran, T., deBoer, T., Etienne, J., Sandhu, M., Wauford, N. A., Chung, J.-Y., Nokes, J., Athaiya, M., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0371-x · Cited by 646
Single‐domain antibody fragments with high conformational stability
Dumoulin, M., Conrath, K., Van Meirhaeghe, A., Meersman, F., Heremans, K., Frenken, L. G. J., Muyldermans, S., Wyns, L., & Matagne, A. (2002) · Protein Science · doi:10.1110/ps.34602 · Cited by 638
Gonzalez-Quintela, A., Alende, R., Gude, F., Campos, J., Rey, J., Meijide, L. M., Fernandez-Merino, C., & Vidal, C. (2007) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.2007.03545.x · Cited by 630
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Aptamers as a replacement for antibodies in enzyme-linked immunosorbent assay
Toh, S. Y., Citartan, M., Gopinath, S. C. B., & Tang, T.-H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.026 · Cited by 612
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Hill, H. D., & Mirkin, C. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.51 · Cited by 588
Hormonal characteristics of the human menstrual cycle throughout reproductive life.
Sherman, B. M., & Korenman, S. G. (1975) · Journal of Clinical Investigation · doi:10.1172/jci107979 · Cited by 587
The physiology of salivary secretion
Proctor, G. B. (2016) · Periodontology 2000 · doi:10.1111/prd.12116 · Cited by 583
Detection principles of biological and chemical FET sensors
Kaisti, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.010 · Cited by 577
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Modern biomaterials: a review—bulk properties and implications of surface modifications
Roach, P., Eglin, D., Rohde, K., & Perry, C. C. (2007) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-006-0064-3 · Cited by 562
Biospecific interaction analysis using biosensor technology
Malmqvist, M. (1993) · Nature · doi:10.1038/361186a0 · Cited by 532
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Single domain antibodies: promising experimental and therapeutic tools in infection and immunity
Wesolowski, J., Alzogaray, V., Reyelt, J., Unger, M., Juarez, K., Urrutia, M., Cauerhff, A., Danquah, W., Rissiek, B., Scheuplein, F., et al. (2009) · Medical Microbiology and Immunology · doi:10.1007/s00430-009-0116-7 · Cited by 513
RNA aptamers as reversible antagonists of coagulation factor IXa
Rusconi, C. P., Scardino, E., Layzer, J., Pitoc, G. A., Ortel, T. L., Monroe, D., & Sullenger, B. A. (2002) · Nature · doi:10.1038/nature00963 · Cited by 512
Multiplexed Point-of-Care Testing – xPOCT
Dincer, C., Bruch, R., Kling, A., Dittrich, P. S., & Urban, G. A. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.013 · Cited by 503
Bandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Toward a new generation of smart skins
Someya, T., & Amagai, M. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0079-1 · Cited by 474
Integrated Magneto–Electrochemical Sensor for Exosome Analysis
Jeong, S., Park, J., Pathania, D., Castro, C. M., Weissleder, R., & Lee, H. (2016) · ACS Nano · doi:10.1021/acsnano.5b07584 · Cited by 469
Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 467
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
DNA Probes: Applications of the Principles of Nucleic Acid Hybridization
Wetmur, J. G. (1991) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.3109/10409239109114069 · Cited by 457
Real-time measurement of small molecules directly in awake, ambulatory animals
Arroyo-Currás, N., Somerson, J., Vieira, P. A., Ploense, K. L., Kippin, T. E., & Plaxco, K. W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1613458114 · Cited by 451
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
A smartphone dongle for diagnosis of infectious diseases at the point of care
Laksanasopin, T., Guo, T. W., Nayak, S., Sridhara, A. A., Xie, S., Olowookere, O. O., Cadinu, P., Meng, F., Chee, N. H., Kim, J., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa0056 · Cited by 425
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living Animals
Ferguson, B. S., Hoggarth, D. A., Maliniak, D., Ploense, K., White, R. J., Woodward, N., Hsieh, K., Bonham, A. J., Eisenstein, M., Kippin, T. E., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007095 · Cited by 419
Adhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Loynachan, C. N., Thomas, M. R., Gray, E. R., Richards, D. A., Kim, J., Miller, B. S., Brookes, J. C., Agarwal, S., Chudasama, V., McKendry, R. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b06229 · Cited by 403
Cortisol in Saliva - Reference Ranges and Relation to Cortisol in Serum
Aardal, E., & Holm, A.-C. (1995) · cclm · doi:10.1515/cclm.1995.33.12.927 · Cited by 398
Nanomaterial-based devices for point-of-care diagnostic applications
Quesada-González, D., & Merkoçi, A. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00837f · Cited by 393
Biosensor Regeneration: A Review of Common Techniques and Outcomes
Goode, J. A., Rushworth, J. V. H., & Millner, P. A. (2015) · Langmuir · doi:10.1021/la503533g · Cited by 392
Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids
Gao, W., Nyein, H. Y. Y., Shahpar, Z., Fahad, H. M., Chen, K., Emaminejad, S., Gao, Y., Tai, L.-C., Ota, H., Wu, E., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00287 · Cited by 391
Self-citationESTRADIOL RADIOIMMUNOASSAY WITHOUT CHROMATOGRAPHY: PROCEDURE, VALIDATION AND NORMAL VALUES
Korenman, S. G., Stevens, R. H., Carpenter, L. A., Robb, M., Niswender, G. D., & Sherman, B. M. (1974) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-38-4-718 · Cited by 384
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Rationally designed molecular beacons for bioanalytical and biomedical applications
Zheng, J., Yang, R., Shi, M., Wu, C., Fang, X., Li, Y., Li, J., & Tan, W. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00020c · Cited by 372
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
van den Bos, R., Harteveld, M., & Stoop, H. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2009.04.016 · Cited by 369
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Automated selection of anti-Protein aptamers
Cox, J. C., & Ellington, A. D. (2001) · Bioorganic & Medicinal Chemistry · doi:10.1016/s0968-0896(01)00028-1 · Cited by 367
Zhang, J., Landry, M. P., Barone, P. W., Kim, J.-H., Lin, S., Ulissi, Z. W., Lin, D., Mu, B., Boghossian, A. A., Hilmer, A. J., et al. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.236 · Cited by 367
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Aptamers in the Therapeutics and Diagnostics Pipelines
Kaur, H., Bruno, J. G., Kumar, A., & Sharma, T. K. (2018) · Theranostics · doi:10.7150/thno.25958 · Cited by 366
Cytokine Levels in the Serum of Healthy Subjects
Kleiner, G., Marcuzzi, A., Zanin, V., Monasta, L., & Zauli, G. (2013) · Mediators of Inflammation · doi:10.1155/2013/434010 · Cited by 356
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Impedimetric immunosensors—A review
Prodromidis, M. I. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2009.01.081 · Cited by 347
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
A magneto-DNA nanoparticle system for rapid detection and phenotyping of bacteria
Chung, H. J., Castro, C. M., Im, H., Lee, H., & Weissleder, R. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.70 · Cited by 339
Bacterial profile of ocular infections: a systematic review
Teweldemedhin, M., Gebreyesus, H., Atsbaha, A. H., Asgedom, S. W., & Saravanan, M. (2017) · BMC Ophthalmology · doi:10.1186/s12886-017-0612-2 · Cited by 337
Van Uum, S. H. M., Sauvé, B., Fraser, L. A., Morley-Forster, P., Paul, T. L., & Koren, G. (2008) · Stress · doi:10.1080/10253890801887388 · Cited by 332
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
Yan, L., Zhu, Z., Zou, Y., Huang, Y., Liu, D., Jia, S., Xu, D., Wu, M., Zhou, Y., Zhou, S., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3114714 · Cited by 329
A review of experimental aspects of electrochemical immunosensors
Ricci, F., Adornetto, G., & Palleschi, G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.06.033 · Cited by 327
Point-of-care biochemical assays using gold nanoparticle-implemented microfluidics
Sun, J., Xianyu, Y., & Jiang, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00125g · Cited by 323
Surface Plasmon Resonance-Based Immunoassays
Mullett, W. M., Lai, E. P. C., & Yeung, J. M. (2000) · Methods · doi:10.1006/meth.2000.1039 · Cited by 322
Smart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status
Kassal, P., Kim, J., Kumar, R., de Araujo, W. R., Steinberg, I. M., Steinberg, M. D., & Wang, J. (2015) · Electrochemistry Communications · doi:10.1016/j.elecom.2015.03.018 · Cited by 319
Use of saliva for monitoring unbound free cortisol levels in serum
Teruhisa, U., Ryoji, H., Taisuke, I., Tatsuya, S., Fumihiro, M., & Tatsuo, S. (1981) · Clinica Chimica Acta · doi:10.1016/0009-8981(81)90353-3 · Cited by 314
Methylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310
Self-citationOkuno, J., Maehashi, K., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.038 · Cited by 309
Yen, C.-W., de Puig, H., Tam, J. O., Gómez-Márquez, J., Bosch, I., Hamad-Schifferli, K., & Gehrke, L. (2015) · Lab on a Chip · doi:10.1039/c5lc00055f · Cited by 308
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Molecular Imprinting Techniques Used for the Preparation of Biosensors
Ertürk, G., & Mattiasson, B. (2017) · Sensors · doi:10.3390/s17020288 · Cited by 292
CTLA4 gene polymorphism and autoimmunity
Gough, S. C. L., Walker, L. S. K., & Sansom, D. M. (2005) · Immunological Reviews · doi:10.1111/j.0105-2896.2005.00249.x · Cited by 288
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 272
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Labelled Antibodies and Immunological Assay Systems
MILES, L. E. M., & HALES, C. N. (1968) · Nature · doi:10.1038/219186a0 · Cited by 269
Lateral-flow technology: From visual to instrumental
Mak, W. C., Beni, V., & Turner, A. P. F. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.017 · Cited by 264
Rational Design of a Minimal Size Sensor Array for Metal Ion Detection
Palacios, M. A., Wang, Z., Montes, V. A., Zyryanov, G. V., & Anzenbacher, P. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802377k · Cited by 262
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
Flexible FET-Type VEGF Aptasensor Based on Nitrogen-Doped Graphene Converted from Conducting Polymer
Kwon, O. S., Park, S. J., Hong, J.-Y., Han, A.-R., Lee, J. S., Lee, J. S., Oh, J. H., & Jang, J. (2012) · ACS Nano · doi:10.1021/nn204395n · Cited by 253
Sensitization of the Hypothalamic‐Pituitary‐Adrenal Axis in Posttraumatic Stress Disordera
YEHUDA, R. (1997) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1997.tb48269.x · Cited by 247
Sahin, E., Grillo, A. O., Perkins, M. D., & Roberts, C. J. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22198 · Cited by 247
Biodegradable and Highly Deformable Temperature Sensors for the Internet of Things
Salvatore, G. A., Sülzle, J., Dalla Valle, F., Cantarella, G., Robotti, F., Jokic, P., Knobelspies, S., Daus, A., Büthe, L., Petti, L., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702390 · Cited by 247
Progress in Boronic Acid-Based Fluorescent Glucose Sensors
Fang, H., Kaur, G., & Wang, B. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039336.51399.3b · Cited by 245
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
Application of microchip assay system for the measurement of C-reactive protein in human saliva
Christodoulides, N., Mohanty, S., Miller, C. S., Langub, M. C., Floriano, P. N., Dharshan, P., Ali, M. F., Bernard, B., Romanovicz, D., Anslyn, E., et al. (2005) · Lab on a Chip · doi:10.1039/b414194f · Cited by 242
Lisowski, P., & Zarzycki, P. K. (2013) · Chromatographia · doi:10.1007/s10337-013-2413-y · Cited by 239
Schoepp, N. G., Schlappi, T. S., Curtis, M. S., Butkovich, S. S., Miller, S., Humphries, R. M., & Ismagilov, R. F. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aal3693 · Cited by 237
Morgan, C. A., Rasmusson, A. M., Wang, S., Hoyt, G., Hauger, R. L., & Hazlett, G. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01319-7 · Cited by 236
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S., Wu, Y., Lau, K. T., Wallace, G., & Diamond, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 235
Portable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231
Aptamer-mediated ‘turn-off/turn-on’ nanozyme activity of gold nanoparticles for kanamycin detection
Sharma, T. K., Ramanathan, R., Weerathunge, P., Mohammadtaheri, M., Daima, H. K., Shukla, R., & Bansal, V. (2014) · Chem. Commun. · doi:10.1039/c4cc07275h · Cited by 231
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Hui, N., Sun, X., Niu, S., & Luo, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11682 · Cited by 227
Holographic Sensors: Three-Dimensional Analyte-Sensitive Nanostructures and Their Applications
Yetisen, A. K., Naydenova, I., da Cruz Vasconcellos, F., Blyth, J., & Lowe, C. R. (2014) · Chemical Reviews · doi:10.1021/cr500116a · Cited by 224
Tseng, P., Napier, B., Garbarini, L., Kaplan, D. L., & Omenetto, F. G. (2018) · Advanced Materials · doi:10.1002/adma.201703257 · Cited by 221
Is Obesity an Oral Bacterial Disease?
Goodson, J. M., Groppo, D., Halem, S., & Carpino, E. (2009) · Journal of Dental Research · doi:10.1177/0022034509338353 · Cited by 220
Two-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Cai, B., Huang, L., Zhang, H., Sun, Z., Zhang, Z., & Zhang, G.-J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.068 · Cited by 212
High-Performance Flexible Graphene Aptasensor for Mercury Detection in Mussels
An, J. H., Park, S. J., Kwon, O. S., Bae, J., & Jang, J. (2013) · ACS Nano · doi:10.1021/nn402702w · Cited by 211
Glucose Sensing with Phenylboronic Acid Functionalized Hydrogel-Based Optical Diffusers
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.7b07082 · Cited by 210
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays
You, D. J., Park, T. S., & Yoon, J.-Y. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.014 · Cited by 208
Gilles, P. N., Wu, D. J., Foster, C. B., Dillon, P. J., & Chanock, S. J. (1999) · Nature Biotechnology · doi:10.1038/7921 · Cited by 203
Walsh, T. R., & Knecht, M. R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00139 · Cited by 194
Ming, K., Kim, J., Biondi, M. J., Syed, A., Chen, K., Lam, A., Ostrowski, M., Rebbapragada, A., Feld, J. J., & Chan, W. C. W. (2015) · ACS Nano · doi:10.1021/nn5072792 · Cited by 192
Rapid antigen tests for dengue virus serotypes and Zika virus in patient serum
Bosch, I., de Puig, H., Hiley, M., Carré-Camps, M., Perdomo-Celis, F., Narváez, C. F., Salgado, D. M., Senthoor, D., O’Grady, M., Phillips, E., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aan1589 · Cited by 192
Principles of Affinity-Based Biosensors
Rogers, K. R. (2000) · Molecular Biotechnology · doi:10.1385/mb:14:2:109 · Cited by 191
Evaluation of saliva as a source of human DNA for population and association studies
Quinque, D., Kittler, R., Kayser, M., Stoneking, M., & Nasidze, I. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.03.021 · Cited by 191
Molecularly Imprinted Polymer Coated Quantum Dots for Multiplexed Cell Targeting and Imaging
Panagiotopoulou, M., Salinas, Y., Beyazit, S., Kunath, S., Duma, L., Prost, E., Mayes, A. G., Resmini, M., Tse Sum Bui, B., & Haupt, K. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201601122 · Cited by 191
Warren, A. D., Kwong, G. A., Wood, D. K., Lin, K. Y., & Bhatia, S. N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1314651111 · Cited by 190
Floriano, P. N., Christodoulides, N., Miller, C. S., Ebersole, J. L., Spertus, J., Rose, B. G., Kinane, D. F., Novak, M. J., Steinhubl, S., Acosta, S., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.117713 · Cited by 190
Magnetic barcode assay for genetic detection of pathogens
Liong, M., Hoang, A. N., Chung, J., Gural, N., Ford, C. B., Min, C., Shah, R. R., Ahmad, R., Fernandez-Suarez, M., Fortune, S. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms2745 · Cited by 189
Paper-based electroanalytical devices for accessible diagnostic testing
Maxwell, E. J., Mazzeo, A. D., & Whitesides, G. M. (2013) · MRS Bulletin · doi:10.1557/mrs.2013.56 · Cited by 189
Wearable Electronics Based on 2D Materials for Human Physiological Information Detection
Pang, Y., Yang, Z., Yang, Y., & Ren, T. (2020) · Small · doi:10.1002/smll.201901124 · Cited by 186
Lee, Y., Howe, C., Mishra, S., Lee, D. S., Mahmood, M., Piper, M., Kim, Y., Tieu, K., Byun, H.-S., Coffey, J. P., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1719573115 · Cited by 183
Comparison of salivary cortisol as measured by different immunoassays and tandem mass spectrometry
Miller, R., Plessow, F., Rauh, M., Gröschl, M., & Kirschbaum, C. (2013) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2012.04.019 · Cited by 181
Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays
Posthuma-Trumpie, G. A., Wichers, J. H., Koets, M., Berendsen, L. B. J. M., & van Amerongen, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5340-5 · Cited by 176
Gaylord, B. S., Massie, M. R., Feinstein, S. C., & Bazan, G. C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407578101 · Cited by 175
Using Commercially Available Personal Glucose Meters for Portable Quantification of DNA
Xiang, Y., & Lu, Y. (2012) · Analytical Chemistry · doi:10.1021/ac203014s · Cited by 175
Materials chemistry in flexible electronics
Chen, X., Rogers, J. A., Lacour, S. P., Hu, W., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c9cs90019e · Cited by 175
Advances in three-dimensional rapid prototyping of microfluidic devices for biological applications
O’Neill, P., Azouz, A. B., Vázquez, M., Liu, J., Marczak, S. P., Slouka, Z., Chang, H., Diamond, D., & Brabazon, D. (2014) · Biomicrofluidics · doi:10.1063/1.4898632 · Cited by 174
Xiang, Y., & Lu, Y. (2012) · Analytical Chemistry · doi:10.1021/ac300517n · Cited by 173
A flexible and wearable biosensor for tear glucose measurement
Iguchi, S., Kudo, H., Saito, T., Ogawa, M., Saito, H., Otsuka, K., Funakubo, A., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9073-3 · Cited by 173
Kim, J., Lee, M., Jeon, S., Kim, M., Kim, S., Kim, K., Bien, F., Hong, S. Y., & Park, J. (2015) · Advanced Materials · doi:10.1002/adma.201500710 · Cited by 172
A digital microfluidic system for serological immunoassays in remote settings
Ng, A. H. C., Fobel, R., Fobel, C., Lamanna, J., Rackus, D. G., Summers, A., Dixon, C., Dryden, M. D. M., Lam, C., Ho, M., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aar6076 · Cited by 172
Advances in nucleic acid-based detection methods
Wolcott, M. (1992) · Clinical Microbiology Reviews · doi:10.1128/cmr.5.4.370 · Cited by 170
Magnetic particles-enabled biosensors for point-of-care testing
Xianyu, Y., Wang, Q., & Chen, Y. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.07.010 · Cited by 167
Nanoporous anti-fouling silicon membranes for biosensor applications
Desai, T. A., Hansford, D. J., Leoni, L., Essenpreis, M., & Ferrari, M. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00088-9 · Cited by 163
Ashizawa, T., Okada, R., Suzuki, Y., Takagi, M., Yamazaki, T., Sumi, T., Aoki, T., Ohnuma, S., & Aoki, T. (2005) · Gastric Cancer · doi:10.1007/s10120-005-0315-x · Cited by 158
Lab‐on‐a‐Chip Methods for Point‐of‐Care Measurements of Salivary Biomarkers of Periodontitis
CHRISTODOULIDES, N., FLORIANO, P. N., MILLER, C. S., EBERSOLE, J. L., MOHANTY, S., DHARSHAN, P., GRIFFIN, M., LENNART, A., BALLARD, K. L. M., KING, C. P., et al. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.035 · Cited by 158
Liu, Y., Liu, R., Qin, Y., Qiu, Q., Chen, Z., Cheng, S., & Huang, W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04223 · Cited by 156
Integrated Biosensor for Rapid and Point-of-Care Sepsis Diagnosis
Min, J., Nothing, M., Coble, B. W., Zheng, H., Park, J., Im, H., Weber, G. F., Castro, C. M., Świrski, F. K., Weissleder, R., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08965 · Cited by 154
Han, W., He, H., Zhang, L., Dong, C., Zeng, H. J., Dai, Y., Xing, L., Zhang, Y., & Xue, X. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07990 · Cited by 153
Immunosensing using nanoparticles
de la Escosura‐Muñiz, A., Parolo, C., & Merkoçi, A. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70125-5 · Cited by 148
Naing, T., Alves, D. R., Bean, J. E., Booth, S. P., Nzakizwanayo, J., Young, A. E., Jones, B. V., & Jenkins, A. T. A. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b07372 · Cited by 143
Enzymatic/Immunoassay Dual‐Biomarker Sensing Chip: Towards Decentralized Insulin/Glucose Detection
Vargas, E., Teymourian, H., Tehrani, F., Ekşin, E., Sánchez‐Tirado, E., Warren, P., Erdem, A., Dassau, E., & Wang, J. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201902664 · Cited by 140
DeSantis, A. S., Diez–Roux, A. V., Hajat, A., Aiello, A. E., Golden, S. H., Jenny, N. S., Seeman, T. E., & Shea, S. (2011) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2011.11.009 · Cited by 138
Farid, M. M., Leila, G., Piri, F., Zamani, A., & Saadati, F. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.07.128 · Cited by 134
Giardino, N. D., Chan, L. E., & Soo Borson, B. (2004) · Applied Psychophysiology and Biofeedback · doi:10.1023/b:apbi.0000026638.64386.89 · Cited by 133
Fratta, I. L., Tatangelo, R., Campagna, G., Rizzuto, A., Franceschelli, S., Ferrone, A., Patruno, A., Speranza, L., Lutiis, M. A. D., Felaco, M., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21474-y · Cited by 133
Clinical Validation of Quantum Dot Barcode Diagnostic Technology
Kim, J., Biondi, M. J., Feld, J. J., & Chan, W. C. W. (2016) · ACS Nano · doi:10.1021/acsnano.6b01254 · Cited by 130
Marques-Deak, A., Cizza, G., Eskandari, F., Torvik, S., Christie, I. C., Sternberg, E. M., & Phillips, T. M. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.07.011 · Cited by 129
Morris, A. C., Kefala, K., Wilkinson, T. S., et al. (2009) · Thorax · doi:10.1136/thx.2009.122291 · Cited by 129
Wireless Flexible Smart Bandage for Continuous Monitoring of Wound Oxygenation
Mostafalu, P., Lenk, W., Dokmeci, M. R., Ziaie, B., Khademhosseini, A., & Sonkusale, S. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2488582 · Cited by 128
Torrente-Rodríguez, R. M., Campuzano, S., Montiel, V. R., Gamella, M., & Pingarrón, J. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.016 · Cited by 126
Self-citationSilva, B. V. M., Rodríguez, B. A. G., Sales, M. G. F., Sotomayor, M. D. P. T., & Dutra, R. F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.068 · Cited by 124
Progesterone and estradiol in the saliva and plasma during the menstrual cycle
Choe, J. K., Khan‐Dawood, F. S., & Yusoff-Dawood, M. (1983) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(83)90016-9 · Cited by 123
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Journal of Fluorescence · doi:10.1023/a:1026103804104 · Cited by 122
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationDevice integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Self-citationElectronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Metadata
- Authors
- Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-11-14
- Volume
- 30
- Issue
- 29
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2985643512
- Cited by
- 357
- References
- 278
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.