The DOI matches its Crossref record; 269 of the 269 references it cites were found in a registry or an index; 19 of the 259 sources its claims cite were checked for support.
A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
Open accessAbstract
Considerable scientific and technological efforts have been devoted to develop neuroprostheses and hybrid bionic systems that link the human nervous system with electronic or robotic prostheses, with the main aim of restoring motor and sensory functions in disabled patients.
Overview
AI snapshot
Written from the paper’s full text.
TL;DR
This review surveys peripheral nervous system interfaces for neuroprostheses and hybrid bionic systems, comparing non-invasive, muscle, extraneural, intraneural, and regenerative electrodes. It concludes that no single interface is universally optimal; selection depends on required selectivity, invasiveness, clinical maturity, and application.
Key findings
- Electrode invasiveness generally tracks selectivity: surface and muscle electrodes are safer and easier but act only on underlying or implanted muscles; cuff and epineurial electrodes interface many axons; intrafascicular, penetrating, and sieve/regenerative electrodes access smaller axon groups but carry greater risk of nerve damage and are mostly research-stage.
- Clinical PNS neuroprostheses are dominated by stimulation: sacral anterior root stimulators for bladder control reached about 2,000 patients worldwide; phrenic pacing, vagus nerve stimulation (postoperative infection under 3%, device removal 1%), cochlear implants, and pain/continence devices are clinical, while recording interfaces for prosthesis control remain largely research.
- Penetrating arrays: Utah MEAs with 25 or 100 needles, including slanted lengths from 0.5 to 1.5 mm, recorded single-unit mechanoreceptor responses in only 10–20% of electrodes and evoked graded muscle recruitment with 1–20 µA currents; responses were stable over 36 hours, and in cat sciatic nerve up to 7 months stimulation stabilized in 80% of electrodes but sensory recordings did not.
- LIFEs implanted in eight amputees for two days allowed voluntary motor signals linked to intended missing-limb movements and elicited graded touch, joint-movement, and position sensations; regenerative sieve electrodes require hole diameters around 40–65 µm, and no human implants have been reported. EMG-based control works for prostheses and exoskeletons but is limited in degrees of freedom, while ENG can provide event and kinematic feedback.
Methods
- Design: critical narrative review, not a primary experimental study; it covers PNS organization, electrode types, materials and fabrication, and control strategies.
- Data or sample: synthesizes prior animal and human studies and clinical experience; no systematic search, inclusion criteria, or primary dataset is described.
- Main analysis: qualitative comparison using tables of advantages/disadvantages and application/status, with discussion of engineering, biological, and clinical tradeoffs.
Limitations
- Stated: no universal best electrode exists; nerve electrodes may damage nerves; cuff, intraneural, and regenerative designs need more study; regenerative electrodes have no human implants; bioelectronic interfaces are early experimental.
- Stated: long-term stability, selectivity, and biocompatibility remain unresolved, and many recording approaches are not clinically mature.
- Evident: as a narrative review from 2005, it lacks a systematic search or meta-analysis and predates later technological and clinical developments.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
19 of 259 cited sources checked · 8 supported · 0 flagged · accuracy not yet measured
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Helical electrodes are widely used for FES of the vagus nerve, which has found therapeutical applications for the control of intractable epilepsy, sleep apnea, and treatment of depressive syndromes (McLachlan, 1997; Fisher and Handforth, 1999) .”
What the sources say
- Not checked — no full text of the sourcecites McLachlan, 1997 source
- Partly supportedcites Fisher and Handforth, 1999 sourceExperimental — accuracy not yet measured
The Abstract (page unavailable) describes an electrode implanted around the left vagus nerve and concludes that vagus nerve stimulation is effective for medically intractable partial seizures. It does not identify the electrode as helical, establish that helical electrodes are widely used, or discuss treatment of sleep apnea or depressive syndromes. (LLM, conf=0.87)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesEvery source the paper cites for this claim was checked and supports it.
In the paper
“Besides the intradural surgical implantation, an epidural implantation procedure was developed (Sauerwein et al., 1990) to enhance the group of patients who may benefit from this kind of neural prosthesis.”
What the sources say
- Supportedcites Sauerwein et al., 1990 source
The paper describes an extradural implantation technique and says it was first used for a patient unsuitable for the standard intrathecal operation (opening section). The Results recommend it for patients who could benefit from a sacral anterior root stimulator but for whom intrathecal surgery would be risky, supporting the claim that the alternative procedure extends eligibility. (LLM, conf=0.91)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The SARS can be also used to restore male sexual and reproductive function (Stief et al., 1992; Brindley, 1995) .”
What the sources say
- Partly supportedcites Stief et al., 1992 sourceExperimental — accuracy not yet measured
The Abstract (p. 5) says the implanted stimulator could induce penile erection, and the Discussion (p. 6) reports full erections in all three men at certain stimulation frequencies. This supports restoration of an aspect of sexual function, but the paper does not establish restoration of reproductive function, such as ejaculation or fertility. (LLM, conf=0.88)
- Not matchedcites Brindley, 1995
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Although involving a more invasive insertion procedure, electrode arrays provided neural contacts with low-force recruitment properties similar to those of single wires.”
What the sources say
- Supportedcites Smit et al., 1999 source
The Abstract states that array-electrode low-force slopes and threshold currents did not differ significantly from those of randomly inserted single wire-microelectrodes. It explicitly concludes that the arrays provided similar low-force recruitment properties despite a more invasive insertion procedure. (LLM, conf=0.95)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Especially for intrafascicular electrodes, no strict inverse recruitment was observed (Veltink et al., 1989) .”
What the sources say
- Could not verifycites Veltink et al., 1989 sourceExperimental — accuracy not yet measured
The supplied passages contain bibliographic metadata, not findings about recruitment. Searches for inverse recruitment with intrafascicular electrodes and for recruitment-order reversal returned no relevant passage, so our copy does not establish whether the paper observed strict inverse recruitment. (LLM, conf=0.72)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“The arrays were capable of evoking threshold forces selectively with high efficiency.”
What the sources say
- Supportedcites Smit et al., 1999 source
The Abstract states that the eight arrays selectively evoked threshold forces with an average efficiency of 0.81 (81%), supporting the description of high efficiency. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Array results revealed partial blocking of neural conduction, similar to that reported with microneurographic insertion with single needles.”
What the sources say
- Supportedcites Smit et al., 1999 source
The Abstract states the claim directly. The section “C. Blocking of Action Potentials” also reports reduced force with stimulation proximal to the array insertion site, indicating partial conduction block, and compares this with findings from single wire-microelectrode insertion. (LLM, conf=0.95)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Motor recruitment was found more stable with stimulation by intrafascicular multielectrodes than by extraneural electrodes.”
What the sources say
- Could not verifycites Veltink et al., 1989 sourceExperimental — accuracy not yet measured
The available copy contains a title and bibliographic records (the passage labeled Abstract, no page given), but no study findings. Searches for stable motor recruitment and for a comparison of intrafascicular with extraneural stimulation found no relevant passage, so the claimed difference cannot be verified from this copy. (LLM, conf=0.73)
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“the extraction of information from natural sensors in the body by processing afferent nerve signals is very challenging (Johnson et al., 1995)”
What the sources say
- Supportedcites Johnson et al., 1995 source
The Background and Rationale section says that using information from natural sensors requires techniques for long-term nerve recording, separating wanted from unwanted information, and relating neural activity to the variables needed for control. The Discussion further describes separating useful signals from noise in whole-nerve recordings and says most processing methods are currently ad hoc. Together, these passages support the characterization of extraction as challenging. (LLM, conf=0.92)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Several features can be extracted in both time and frequency domains (Zardoshti-Kermani et al., 1995; Englehart, 1998; Pattichis and Pattichis, 1999; Sparto et al., 2000) that increase the possibility of controlling more than two degrees of freedom of the prosthesis when used in combination with advanced classification algorithms (Kelly et al., 1990; Christodoulou and Pattichis, 1999; Micera et al”
What the sources say
- Not checked — no full text of the sourcecites Zardoshti-Kermani et al., 1995 source
- Not checked — no full text of the sourcecites Englehart, 1998
- Supportedcites Pattichis and Pattichis, 1999 source
The citation to Pattichis and Pattichis is attached to the statement that features can be extracted in both time and frequency domains, not to the later prosthesis-control claim. Section D (Table IV) lists time-domain and frequency-domain parameters extracted from motor unit action potentials. (LLM, conf=0.93)
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passes
- It may state two separate claims as one. 94
- Probably not a substantial claim. 46
- The quote only partly states this claim. 1
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Nowadays, the most frequent use of PNS interfaces resides in FES, which has clinical applications in various systems designed to control micturition and defecation by stimulating the sacral roots”
What the sources say
- Partly supportedcites Brindley et al., 1986 sourceExperimental — accuracy not yet measured
The Discussion reports that most patients used sacral anterior root stimulators mainly for micturition. Methods and Results also reports that a few used S3 or S4 stimulation to aid defaecation. The paper does not establish that FES is the most frequent use of PNS interfaces overall. (LLM, conf=0.87)
- Not checked — no full text of the sourcecites Creasey, 1993 source
- Not checked — no full text of the sourcecites Van Kerrebroeck et al., 1993 source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Acoustic signals increase in parallel with surface EMG signals during voluntary and evoked contraction, but acoustic amplitude decays with fatigue whereas EMG amplitude does not”
What the sources say
- Partly supportedcites Barry et al., 1985 sourceExperimental — accuracy not yet measured
The Abstract reports that acoustic amplitude decayed with fatigue while surface EMG amplitude did not, and the Figure 5 discussion describes both signals increasing together when voluntary effort increased. The copy does not establish that they increase in parallel during evoked contractions; the Discussion describes external nerve stimulation as a proposed future test. It also notes that surface EMG began to decay below 45% of maximal voluntary contraction, so the claim that EMG amplitude does not decay needs qualification. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Partly supportedcites Barry et al., 1992 sourceExperimental — accuracy not yet measured
The Results (page unavailable) report that vibration amplitude declines with fatigue, but also state that the evoked compound muscle action potential (CMAP) declines, though less rapidly. The discussion (page unavailable) says surface EMG amplitude typically does not decline during moderate voluntary contractions. The paper does not support the broader claim that acoustic and EMG signals increase in parallel during both types of contraction, or that electrical-signal amplitude does not decline with evoked fatigue. (LLM, conf=0.88)
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“After more than 10 years of development, Brindley's group reported the first 50 cases of a radio frequency-controlled implant from series production with medical approval called sacral anterior root stimulator (SARS) in humans (Brindley et al., 1986) .”
What the sources say
- Partly supportedcites Brindley et al., 1986 sourceExperimental — accuracy not yet measured
The Abstract reports the first 50 human recipients of sacral anterior root stimulators; Methods and Results describes external radio transmitters, and the References include development work dating to 1972. But the printed sentence goes further: Methods and Results says the first 11 implants were made in the Neurological Prostheses Unit, not series-produced, and our copy does not establish medical approval. (LLM, conf=0.87)
Strength:plain· not yet calibratedn = 50Tests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The implant was commercialized as FinetechBrindley stimulator, and less than a decade later 500 patients benefited from the system (Brindley, 1994) .”
What the sources say
- Partly supportedcites Brindley, 1994 sourceExperimental — accuracy not yet measured
The Introduction says the 500th London-design stimulator was implanted in February 1992, and Sources of information identifies Finetech Medical Ltd as the manufacturer. The paper does not date commercialization, so it cannot establish the claimed interval of less than a decade. Its benefits discussion describes potential benefits but does not establish that all 500 patients benefited. (LLM, conf=0.86)
Tests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In acute experiments, multiple-wire-microelectrode arrays were inserted into rat nerves to investigate selective stimulation of motor units (Smit et al., 1999) .”
What the sources say
- Supportedcites Smit et al., 1999 source
The Abstract states that, in acute experiments, eight wire-microelectrode arrays were inserted into the rat common peroneal nerve to investigate selective stimulation of motor units in the extensor digitorum longus muscle. This directly supports the citing sentence. (LLM, conf=0.95)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The histology of animal nerves that had metal or polymer LIFEs implanted for a period of 6 months revealed that the implants are biocompatible and that no damage was caused by the presence of the electrode, although a slight increase in connective tissue surrounding the implant site was evident in the longterm (Lefurge et al., 1991; Lawrence et al., 2002) .”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The activity of embryonic spinal cord cells of mice has been recorded simultaneously over a period of several months on a planar glass substrate with 64 iridium tin oxide electrodes (Droge et al., 1986)”
What the sources say
- Partly supportedcites Droge et al., 1986 sourceExperimental — accuracy not yet measured
The Cell culture section describes recordings from embryonic mouse spinal-cord cells, and the paper describes simultaneous multisite recording. But its recording matrix had 36 gold-conductor electrodes, not 64 iridium tin oxide electrodes; the Results describe cultures examined 3–5 weeks after seeding, not recordings over several months. No page numbers are available in our copy. (LLM, conf=0.90)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Different complex algorithms have been developed to extract force/torque information from sEMG signals that address these limitations, although in some cases good results have been achieved using a simple proportional control law (Gordon and Ferris, 2004)”
What the sources say
- Partly supportedcites Gordon and Ferris, 2004 sourceExperimental — accuracy not yet measured
The Virtual object interface section describes a simple proportional law: processed surface EMG amplitudes generated virtual forces, and the Discussion reports that subjects improved their control with practice. The Discussion also mentions signal-processing algorithms for myoelectric prostheses, but our copy does not say those algorithms extract force or torque from sEMG; the study's proportional forces were virtual, not measured force or torque estimates. Page numbers are unavailable in our copy. (LLM, conf=0.85)
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Partly supported
In the paper
“The patients learned to open and close the hand reliably after a few minutes of practice”
What the sources say
- Not matchedcites Barry et al., 1986
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Attempts to develop material surfaces that may be recognized as biological and form truly biocompatible interfaces with the tissue are under investigation, although they have yet to be integrated in functional neural interfaces.”
Strength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Extraneural electrodes, such as cuff and epineurial electrodes, provide simultaneous interface with many axons in the nerve”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“However, nerve electrodes also have the potential to damage the nerves on which they are implanted, whereas muscle electrodes are generally considered as safer”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Signals are transmitted by the corresponding axons in series of impulses or action potentials, with intensity of the signal mainly coded in impulse frequency along the peripheral axon.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
- Rests on an assumption: Signals are transmitted by axons in series of impulses or action potentials, with intensity mainly coded in impulse frequency along the peripheral axon.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Patients are able to use the system for activities of daily living and enhancing their quality of life and independency.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Nerve fibers, both afferent and efferent, are grouped in fascicles surrounded by connective tissue in the peripheral nerve”
What the sources say
- Not matchedcites Peters et al., 1991
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
In the paper
“New technological developments are taking into account the fact that the most patients with nervous system injury suffer from an incomplete lesion, and thus modular, controllable systems for supporting these functions are being developed”
What the sources say
- Not checked — no full text of the sourcecites Rupp and Gerner, 2004 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Recruitment of motor units follows an order of size, with slow fatigue-resistant motor units activated first and large fast-fatigue motor units activated only at high levels of tension.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
- Rests on an assumption: Recruitment of motor units follows an order of size, with slow fatigue-resistant motor units activated first and large fast-fatigue motor units activated only at high levels of tension.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The fascicular architecture changes throughout the length of the nerve, with an increasing number of fascicles of smaller size in distal with respect to proximal segments.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Rests on an assumption: The fascicular architecture changes throughout the length of the nerve, with an increasing number of fascicles of smaller size in distal compared with proximal segments.
In the paper
“Due to the proximity to the nerve, the stimulus intensity required for activation is reduced in comparison with muscular or surface electrodes and, consequently, hazardous electrochemical processes and power consumption of the stimulator system can be decreased”
What the sources say
- Not checked — no full text of the sourcecites Loeb and Peck, 1996 source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“The perineurium is the main contributor to the tensile strength of the nerve, acts as a diffusion barrier, and maintains the endoneurial fluid pressure.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
- Rests on an assumption: The perineurium is the main contributor to the tensile strength of the nerve, acts as a diffusion barrier, and maintains the endoneurial fluid pressure.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“intrafascicular, penetrating, and regenerative electrodes may contact small groups of axons within a nerve fascicle”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“In general, the compatibility between a technical and a biological system (Bronzino, 1995) can be divided into the structural biocompatibility and the surface biocompatibility”
What the sources say
- Not matchedcites Bronzino, 1995
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“In general, they offer a good signal-to-noise ratio because of their position and large surface and provide exact selectivity, namely the implanted muscle.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“For recording purposes, electrodes made of silver/silver chloride in the form of bars (10 -1 mm) have been found to give adequate signal-to-noise ratio.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
In the paper
“Multichannel (linear and high-density arrays) surface EMG electrodes have been developed that enable measurements of motor unit potentials size and number and provide topographical information that is beyond the capability of intramuscular needle electrodes”
What the sources say
- Not checked — no full text of the sourcecites Zwarts and Stegeman, 2003 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“they can also be employed to supply a perceivable sensation to the skin or to excite nerve tracts or muscles underneath the skin”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Disadvantagesinclude the susceptibility to interference by environmental noise and vibrations and limited experience with its use.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“A final issue with percutaneous electrodes is that muscle contractions may result in eventual breakage, although these problems have become less frequent with the improvement of electrodes and lead wires”
What the sources say
- Not checked — no full text of the sourcecites Onishi et al., 2000 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The active recording electrode should be located near but not on the motor point because at this point the stability of signals suffers from minor physical displacement of the electrode”
What the sources say
- Not matchedcites De Luca, 2002
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further technical developments to increase sensitivity of measurements are needed before magnetic interfaces can be used for single-unit activity recordings.”
Strength:plain· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Although they can be used for EMG recording, the main application area is for muscle stimulation”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The number of electrodes to be used depends on the working application: low number of electrodes for robust use and limited functionality or high numbers for good spatial resolution and selectivity”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Muscle sounds have been used to measure twitch force, monitor fatigue and in the diagnosis of muscle diseases.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As a control signal for externally powered prostheses, acoustic myography may present some advantages over surface EMG because it is unaffected by changes in skin impedance, less sensitive to placement on the muscle, and requires less amplification and electrical shielding.”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The impedance at the electrode-skin interface is largely variable between individuals at low frequencies, whereas at high frequencies the decline of impedance values with time depends on the electrode type”
What the sources say
- Not checked — no full text of the sourcecites Hewson et al., 2003 source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“cuff and intrafascicular electrodes can be applied to intact nerves in acute or chronic studies, whereas, by definition, regenerative sieve electrodes are implanted in transected nerves that need to regenerate across the electrode sieve over several months.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“These electrodes may damage many muscle fibers, but in most instances this loss will not represent a noticeable reduction in muscle force”
What the sources say
- Not checked — no full text of the sourcecites Mortimer et al., 1980 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“To minimize external contamination, measurements are usually performed inside a magnetically shielded room, thus limiting its application for control of neuroprostheses.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Compared with nerve cuff electrodes, intramuscular electrodes have been shown to produce more reliable, more graded, and less fatigable recruitment of motor units”
What the sources say
- Not checked — no full text of the sourcecites Singh et al., 2000
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“In addition, high energy consumption is required to activate the muscle.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“To avoid problems derived from excess charge delivery, stimulation is given in cycles, and the system is explanted once regenerating axons reinnervate the muscles of interest.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“This device consists of a small cylindrical capsule (16 -2 mm) whose internal components are connected to electrodes sealed hermetically into its ends.”
What the sources say
- Not checked — no full text of the sourcecites Loeb et al., 2001 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“Electrode and lead failures or infections have been found to be rare and the electrode response was stable over time in patients with intramuscular or epimysial electrodes during more than 3 years”
What the sources say
- Not checked — no full text of the sourcecites Kilgore et al., 2003 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“In addition, the currents required to produce contractions are high and may induce discomfort and tissue damage”
What the sources say
- Not checked — no full text of the sourcecites Chae and Hart, 1998 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Adequate EMG signals can be obtained with epimysial and intramuscular electrodes, but the fatigue of the muscle and the derived change of the recorded signal have to be taken into account for long-term use.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Tests performed indicated that the BION is a stable, biocompatible, and effective electrode when implanted passively or used to stimulate muscles in experimental animals for long-term implantation (Cameron et al., 1998) .”
What the sources say
- Not checked — no full text of the sourcecites Cameron et al., 1998 source
Strength:hedged· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Management may be difficult when many epimysial electrodes on different muscles are used because of the interconnection between them, providing additional risks and possible source of failure.”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Their main advantage of being non-invasive and easily adaptable is counteracted by several disadvantages, such as the need for daily placement and frequent calibration, and by the low reproducibility and quality of acquired signals.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Currently, recorded EMG signals are used to determine the activation time of a muscle, to estimate the force produced during muscle contraction and to estimate the rate of muscle fatigue.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Capacitive electrodes such as titanium nitride might reduce the risk of corrosion under stimulation conditions, but their performance highly varies with the fabrication technology”
What the sources say
- Not matchedcites Janders et al., 1996
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Weiland et al., 2002 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“For large muscles, the EMG activity mainly reflects the action potentials of motor units located more superficial or closer to the electrode.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
In the paper
“This requires the implantation and maintenance of many electrodes subjected to considerable mechanical stress caused by strong muscle contractions”
What the sources say
- Not checked — no full text of the sourcecites Devasahayam, 1992 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The choice of an adequate electrode size and material, in combination with a 'structural compatible' design, is always a compromise between electrode impedance, signal-to-noise ratio, and selectivity.”
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
In the paper
“Direct muscle stimulation may be also used to recover chronically denervated muscles, although activation requires long duration pulses and extremely high current that are usually not generated by common FES devices”
What the sources say
- Not checked — no full text of the sourcecites Kern et al., 2002 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“There was no gross evidence of axonal damage after 1 day, but chronic implants have not been reported.”
What the sources say
- Not checked — no full text of the sourcecites Tyler and Durand, 1997 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“For example, quasi-trapezoidal stimulation pulses have been shown to induce more gradual contraction than rectangular pulses, an effect that was attributed to activation of fatigue-resistant motor units before activation of large fast-fatigue units with cuff electrodes (Fang and Mortimer, 1991; Rozman et al., 1993) .”
What the sources say
Strength:boosted· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“The use of short pulsewidths and the introduction of a subthreshold transverse current from a steering anode allows restriction of the region of excitation of the nerve trunk, significantly improving the selectivity of stimulation (Gorman and Mortimer, 1986; Sweeney et al., 1990; Grill and Mortimer, 1996b; Navarro et al., 2001) .”
What the sources say
- Not matchedcites Gorman and Mortimer, 1986
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Sweeney et al., 1990 source
- Not matchedcites Grill and Mortimer, 1996b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Although snug-fitting nerve cuffs have been advocated to reduce the stimulus charge injection or to obtain a high signal-to-noise ratio for neural recordings (Naples et al., 1990) , different studies have shown that chronic implantation of snug cuffs modifies the nerve shape and produces a loss of large nerve fibers, which are the most sensitive to compression (Krarup et al., 1989; Grill and Mort”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Tripolar (central active electrode vs. two reference electrodes near the ends of the cuff) electrode configuration is preferred to reduce noise pickup (Stein et al., 1977) ; it provides a biophysically ideal way to use a differential amplifier to reject almost completely the large bioelectric signals arising from outside the cuff (e.g., EMG).”
What the sources say
- Not checked — no full text of the sourcecites Stein et al., 1977 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Histological cross-sections showed that the SPINE rearranges the epineurium and penetrates deep within a multifascicular nerve but did not disrupt the perineurium (Tyler and Durand, 1997) .”
What the sources say
- Not checked — no full text of the sourcecites Tyler and Durand, 1997 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“By flattening the nerve into a more elliptical shape, fascicles become more accessible and central fibers are moved closer to the stimulating electrode in comparison with cylindrical cuffs.”
What the sources say
- Not checked — no full text of the sourcecites Tyler and Durand, 2002 source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“The first micturition because of electrical nerve root stimulation was reported in 1973 (Brindley, 1973) .”
What the sources say
- Not matchedcites Brindley, 1973
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
In the paper
“Postoperative infections after helicoidal electrode implants in vagus nerve patients occur in less than 3% of cases, requiring removal of the device in 1%.”
What the sources say
- Not checked — no full text of the sourcecites McLachlan, 1997 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Helicoidal electrodes, placed circumjacent to the nerve, are made of flexible platinum ribbon with an open helical design (Fig. 5), allowing the electrode to conform to the shape of the nerve and minimizing mechanical trauma (Naples et al., 1990) .”
What the sources say
- Not matchedcites Naples et al., 1990
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Electrodes that moderately flattened the nerve demonstrated the best selectivity for limb motion measurements, which were maintained throughout the implant time (Tyler and Durand, 2003; Leventhal and Durand, 2004) .”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“The latter application is of limited benefit because it should be applied only when pain involves one nerve territory in the head or the limbs and has frequent morbidity associated with electrode approximation, electrode displacement, and lead failure (Hassenbusch et al., 1996) .”
What the sources say
- Not checked — no full text of the sourcecites Hassenbusch et al., 1996 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Results on acute experiments showed that it is possible to selectively activate individual fascicles of the cat sciatic nerve with the FINE, as well as groups of fibers within the fascicles, and revealed the strong dependency of selectivity on the relative locations of the fascicle and the electrode contacts (Tyler and Durand, 2002; Leventhal and Durand, 2003) .”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Because ventral root stimulation produces simultaneous contraction of both sphincter and detrusor muscles, voiding is achieved in brief spurts at the end of the stimulation, when the striated sphincter muscle relaxes faster than the smooth detrusor muscle.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Occasional fracture of the electrode wire has been reported (McLachlan, 1997) .”
What the sources say
- Not checked — no full text of the sourcecites McLachlan, 1997 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Nowadays, there are 2,000 patients worldwide that carry a urinary bladder stimulator (Rijkhoff, 2004) .”
What the sources say
- Not checked — no full text of the sourcecites Rijkhoff, 2004 source
Strength:plain· not yet calibratedn = 2,000Tests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
None of the sources cited for this claim have been checked yet.
In the paper
“Epineurial electrodes are used in biomedical FES applications for breathing control by phrenic nerve stimulation (Creasey et al., 1996) , foot-drop improvement (Liberson et al., 1961) , and relief of neuropathic pain (Strege et al., 1994) .”
What the sources say
- Not matchedcites Creasey et al., 1996
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites Liberson et al., 1961
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Strege et al., 1994 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Chronic studies in laboratory animals with FINE implanted over 1-3 months showed that electrodes applying high reshaping force induced nerve damage, whereas those with moderate and small forces did not cause any detectable change in nerve physiology and histology.”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Applicability of regenerative electrodes is dependent on the success of axonal regeneration through the perforations or holes, the possibility of nerve damage from the mechanical load imposed by the electrode or from constrictive forces within the holes, and the biocompatibility of the components (Rosen et al., 1990; Navarro et al., 1996) .”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Recruitment curves for the electrode array were broader with twitch thresholds starting at much lower currents than usual for cuff electrodes.”
What the sources say
- Not checked — no full text of the sourcecites Branner et al., 2001 source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“An interesting study used a microelectrode to stimulate the sensory nerve of an operator to indicate contact with an object by a remote robotic hand (Shimojo et al., 2003) .”
What the sources say
- Not matchedcites Shimojo et al., 2003
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
In the paper
“One negative aspect was the gradual degradation of the electrode wire bundle.”
What the sources say
- Not checked — no full text of the sourcecites Warwick et al., 2003 source
Strength:plain· not yet calibratedSingle caseTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“To decrease the number of redundant electrodes and provide access to more fascicles within the nerve, a slanted array with electrodes of varying length, ranging from 0.5 to 1.5 mm with 0.1 mm difference in length between rows of neighboring electrodes, has been developed (Branner et al., 2001) .”
What the sources say
- Not checked — no full text of the sourcecites Branner et al., 2001 source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Using multiple-hole silicon arrays, the researchers demonstrated axonal regeneration and even neural activity recording was demonstrated in peripheral nerves of rat, frog, and fish (Kovacs et al., 1994; Navarro et al., 1996; Bradley et al., 1997; Della Santina et al., 1997; Mensinger et al., 2000) .”
What the sources say
Strength:boosted· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Activity arising from cutaneous receptors in response to stimuli has been recorded in several studies, although activity was found to be small and difficult to distinguish from the background noise in the recording (Malmstrom et al., 1998; Yoshida et al., 2000) .”
What the sources say
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“In a series of experimental and modeling studies, Rutten and colleagues concluded that an electrode separation of 120 m m was optimal for selective interfacing peripheral nerves, such as the rat peroneal”
What the sources say
- Not checked — no full text of the sourcecites Rutten, 2002 source
Strength:boosted· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Thus, a trade-off must be made between selectivity of stimulation and the total number of nerve fibers that can be activated; optimal selectivity requires the use of redundant electrodes in the 3D configuration (Rutten et al., 1999) .”
What the sources say
- Not checked — no full text of the sourcecites Rutten et al., 1999 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Microstimulation through the electrode can be used to activate single axons, although in most cases stimulation affects small groups of axons in the fascicle (Ochoa and Torebjo ¨ rk, 1983; Torebjo ¨ rk et al., 1987) .”
What the sources say
- Not checked — no full text of the sourcecites Ochoa and Torebjo ¨ rk, 1983 source
- Not matchedcites Torebjo ¨ rk et al., 1987
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Regenerating axons eventually grow through the holes (Fig. 12), making it possible to record action potentials from and to stimulate individual axons or small fascicles.”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“The subject received feedback information from force and slip sensors in a prosthetic hand and subsequently used the array to control the hand for grasping an unseen object.”
What the sources say
- Not checked — no full text of the sourcecites Warwick et al., 2003 source
Tests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The stimulation properties stabilized in 80% of the electrodes over the course of the experiment, but the recorded sensory signals were not stable over time.”
What the sources say
- Not checked — no full text of the sourcecites Branner et al., 2004 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The Utah MEA is also capable of recording more effectively from more dorsal root ganglion neurons than has been achieved by conventional recording techniques, providing a more stable option for chronic implantation (Aoyagi et al., 2003) .”
What the sources say
- Not checked — no full text of the sourcecites Aoyagi et al., 2003 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Ideally a one-to-one design would allow access to each individual regenerated axon grown through one hole (2-10 m m in diameter). However, this has been proved impossible; nerve regeneration fails with holes of such small size.”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Electrodes in the array were capable of selectively recording single-unit responses from mechanoreceptors, although only in 10-20% of the electrodes, and evoked graded recruitment of force in muscle groups in a highly selective fashion with current injections in the 1-20 m A range (Branner and Norman, 2000; Branner et al., 2001) .”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“The LIFEs offer good selectivity for stimulation (Nannini and Horch, 1991; Yoshida and Horch, 1993) and for multiunit extracellular recording (Goodall et al., 1991; McNaughton and Horch, 1994; Yoshida and Stein, 1999) , and their geometry, make them suitable for longterm implantations (Lefurge et al., 1991) .”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“The use of multistrand Kevlar LIFEs (m-polyLIFE) increases the tensile strength and signal-to-noise ratio (Lawrence et al., 2004) .”
What the sources say
- Not checked — no full text of the sourcecites Lawrence et al., 2004 source
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“However, such silicon interfaces cause frequent signs of axonopathy and constitute a physical barrier that limits the elongation of regenerating axons depending on the size of the holes (Edell, 1986; Rosen et al., 1990; Navarro et al., 1996; Zhao et al., 1997) .”
What the sources say
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
In the paper
“Both the recording and stimulation were stable over the 36-h-long period of the experiments.”
What the sources say
- Not checked — no full text of the sourcecites Branner et al., 2001 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Nevertheless, the loss of neurons in spiral ganglion and cochlear nucleus was found, thought to be due to difficulty with electrode insertion and chronic motion of the implants.”
What the sources say
- Not checked — no full text of the sourcecites Arts et al., 2003 source
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“A silicon-based ribbon electrode with high flexibility demonstrated successful function after chronic implantation of up to 1 year (Hetke et al., 1994) , but this interconnect cable was not designed for implants in the highly mobile somatic peripheral nerve and was too stiff and brittle for intrafascicular application (Najafi and Hetke, 1990) .”
What the sources say
Strength:boosted· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the PNS, bioelectronic interfaces are in an early and experimental stage.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
In the paper
“Pine et al . (1994) managed to place single hippocampus cells of the rat into a 3D silicon structure, which was termed 'cultured neuron probe.' They could demonstrate that the transplanted cells inside the microcompartments retained their capacity for axonal outgrowth and that nerve action potentials could be directly recorded extracellularly from the soma of the cells.”
What the sources say
- Not matchedcites Pine et al., 1994
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:boosted· not yet calibratedSingle caseTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
In the paper
“they obtained a current-free measurement of the membrane potential of a single neuron of a leech by direct coupling to the gate of a field effect transistor (FET) (Fromherz et al., 1991a)”
What the sources say
- Not matchedcites Fromherz et al., 1991a
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:plain· not yet calibratedSingle caseTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
None of the sources cited for this claim have been checked yet.
In the paper
“been possible to stimulate different nerve bundles and to record nerve action potentials in response to functional stimulation (Navarro et al., 1998; Ceballos et al., 2002)”
What the sources say
- Not matchedcites Navarro et al., 1998
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Ceballos et al., 2002 source
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“the formal scheme for the acquisition and analysis of EMG signals for the control of prosthetic devices is composed of several modules (Zecca et al., 2002) : (1) signal conditioning, pre-processing, and detection of onset movement (Micera et al., 1999) ; (2) feature extraction; (3) dimensionality reduction; (4) pattern recognition; and (5) off-line and on-line learning.”
What the sources say
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“The fabrication of silicon-based interconnection cables was shown to be technologically feasible (Hetke et al., 1990; 1994)”
What the sources say
- Not matchedcites Hetke et al., 1990; 1994
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:boosted· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“some time is needed for interfacing the regenerated axons, thus precluding acute experiments”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“The presence of a polyimide-based regenerative electrode showed no chronic foreign body response, and the immunohistochemically measured pattern of characteristic proteins was comparable with a healing reaction without any implant (Klinge et al., 2001a) .”
What the sources say
- Not checked — no full text of the sourcecites Klinge et al., 2001a source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In this case, it is usually not possible to use the 'homologous' muscles to control the movements of the prosthetic device, and the development of a complex algorithm exploiting the potentialities of using advanced pattern recognition techniques is required.”
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“the EMG signal was modeled as the amplitude-modulated Gaussian noise whose variance is related to the force developed by the muscle.”
What the sources say
- Not matchedcites Graupe and Cline, 1975; 1982
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Graupe et al., 1982 source
Strength:plain· not yet calibratedCausal:correlational· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“sEMG signals are easy to record and provide an important access to the neuromuscular system of the user.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✗ Based: failsProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“The structure's topology (e.g., the width of grooves) has an important impact on the growth of the cultured cells (Wilkinson et al., 1987; Clark et al., 1990; Connolly et al., 1992)”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Silicone elastomer is still the material of choice for encapsulation of cables and also as additional coating for hermetically sealed electronic circuits (Stieglitz et al., 2004)”
What the sources say
- Not checked — no full text of the sourcecites Stieglitz et al., 2004 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Polyimide-based electrodes have been shown to be biocompatible and stable over months of in vivo implantation and allow for much better regeneration than silicon dice (Navarro et al., 1998; Ceballos et al., 2002; Lago et al., 2005) .”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Fromherz et al . (1991b) could demonstrate the guided growth of nerve cells from leeches on a laminin-coated substrate.”
What the sources say
- Not matchedcites Fromherz et al., 1991b
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
- Not matched
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“One of the most logical and challenging applications of regenerative electrodes consists of their implantation in severed nerves of an amputee's limb for bidirectional interface in a feedback-controlled neuroprosthesis.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Here, a piece of a rat sciatic nerve was placed into a cone of 1.5 mm length and 100-200 m mdiameter. After implantation in the brain of a rat, neurite ingrowth was observed and stable recordings were obtained over 6 months.”
What the sources say
- Not checked — no full text of the sourcecites Kennedy, 1989 source
Strength:plain· not yet calibratedSingle caseTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Neither approach has been investigated in the PNS.”
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
None of the sources cited for this claim have been checked yet.
In the paper
“Materials typically used are platinum, iridium, tungsten, and stainless steel as conductors and silicone elastomer, polytetrafluoroethylene, and polyimide as insulating carriers (Naples et al., 1990; Heiduschka and Thanos, 1998)”
What the sources say
- Not matchedcites Naples et al., 1990
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Heiduschka and Thanos, 1998 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
- Not matched
A claim is checked only against the cited paper’s full text, never its abstract, and none is available for its sources.
In the paper
“Having surface topologies on the substrate, axonal outgrowth of embryonic nerve cells from rats was observed and electrical activity was recorded in a microstructure with 16 electrodes that were connected with grooves (Jimbo and Kawana, 1992; Jimbo et al., 1993)”
What the sources say
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
In the paper
“Reinnervation of the gastrocnemius and tibialis muscles via the distal stump of the sciatic nerve was observed after a few weeks, although there was no communication with the CNS.”
What the sources say
- Not checked — no full text of the sourcecites Katsuki et al., 1997 source
Strength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“sensory feedback from tactile and force sensors might be provided to the user through stimulation of afferent nerve fibers within the residual limb (Riso, 1999)”
What the sources say
- Not checked — no full text of the sourcecites Riso, 1999 source
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesProbably not a substantial claim.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“but cost, technology, and limited cable length limit widespread use in neural prostheses applications”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The devices are robust, stable, and reliable but suffer from a low spatial resolution and low selectivity of the electrodes as well as from a quite large size.”
Strength:plain· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Functional regeneration was proven but the number of surviving cells tremendously decreased from the 10,000 that had been injected to some tens that finally innervated the muscle (T. Stieglitz, 2004. The neuron micro probe project, personal communication)”
What the sources say
- Not checked — no full text of the sourcecites T. Stieglitz, 2004. The neuron micro probe project, personal communication source
Tests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“deterioration of the device may result in implant failure and the release of toxic products”
Strength:hedged· not yet calibratedCausal:conditional· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
In the paper
“Using this approach, it was possible to control the different degrees of freedom of the shoulder reducing the muscular effort of the subjects.”
What the sources say
- Not matchedcites Kiguchi et al., 2001; 2003
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
- Not matched
The paper states this without a source or data behind it here, so there is nothing to check it against. The quote shows it is in the paper.
In the paper
“Neuro-fuzzy models seem the most adequate because of their model-free structure.”
Strength:hedged· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✗ Load-bearing: fails✓ Based: passesProbably not a substantial claim. The paper’s conclusions may not depend on it.
In the paper
“Experimental tests have shown that the use of sEMG significantly improved the mechanical gain of the system (i.e., the possibility of augmenting capabilities and/or reducing human muscular efforts to carry out the different tasks) while maintaining natural control of the system.”
What the sources say
- Not checked — no full text of the sourcecites Rosen et al., 2001 source
Strength:boosted· not yet calibratedCausal:direct· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“At the moment, there is no universal best choice for all possible uses of the described interfaces”
Load-bearingStrength:plain· not yet calibratedTests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✗ Based: failsProbably not a substantial claim. The paper may give no reason why it holds.
In the paper
“Using this schemea one-degree-of-freedom exoskeleton has been controlled using a multiple-feedback approach: (1) dynamic feedback - the moments generated at the interfaces between the human arm, the external load, and the exoskeleton structure; (2) kinematic feedback -the joint angular trajectories recorded using encoders, and the angular velocity and acceleration calculated by finite differences;”
What the sources say
- Not checked — no full text of the sourcecites Rosen et al., 2001 source
Tests✓ Asserted: passes✓ Checkable: passes? Load-bearing: unclear✓ Based: passesThe quote only partly states this claim.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“This approach seems promising for the development of EMG-based controlled hand prostheses although the use of EMG signals seems to be limited to prosthesis with a few degrees of freedom (probably no more than four).”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
A conclusion the paper draws from its own results — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“by using this approach, the user must initiate all the contractions to control the prosthesis from rest, making it difficult to switch from one class to another and increasing the response time of the user when dealing with unexpected situations.”
Tests✓ Asserted: passes✓ Checkable: passes✓ Load-bearing: passes✓ Based: passesIt may state two separate claims as one.
The paper relies on this without support.
Nerve fibers are recruited by electrical stimulation according to their thickness, so large motor fibers are activated earlier than thinner fibers.
“nerve fibers are recruited by electrical stimulation according to their thickness, therefore large motor fibers innervating the fast-fatigue and strong motor units are activated earlier than the physiologically first-recruited thinner fibers controlling slow fatigue-resistant motor units”
The paper relies on this without support.
Recruitment of motor units follows an order of size, with slow fatigue-resistant motor units activated first and large fast-fatigue motor units activated only at high levels of tension.
“Recruitment of motor units follows an order of size, with slow fatigue-resistant motor units activated first and large fast-fatigue motor units activated only at high levels of tension.”
The paper relies on this without support.
Signals are transmitted by axons in series of impulses or action potentials, with intensity mainly coded in impulse frequency along the peripheral axon.
“Signals are transmitted by the corresponding axons in series of impulses or action potentials, with intensity of the signal mainly coded in impulse frequency along the peripheral axon.”
The paper relies on this without support.
The fascicular architecture changes throughout the length of the nerve, with an increasing number of fascicles of smaller size in distal compared with proximal segments.
“The fascicular architecture changes throughout the length of the nerve, with an increasing number of fascicles of smaller size in distal with respect to proximal segments.”
The paper relies on this without support.
The perineurium is the main contributor to the tensile strength of the nerve, acts as a diffusion barrier, and maintains the endoneurial fluid pressure.
“The perineurium is the main contributor to the tensile strength of the nerve, acts as a diffusion barrier, and maintains the endoneurial fluid pressure.”
The paper relies on this without support.
Using multiple wire needles to interface a high number of nerve fibers has practical problems for long-term use.
“However, the use of multiple wire needles for interfacing a high number of nerve fibers has practical problems for long-term use.”
The paper relies on this without support.
No human implants of regenerative electrodes have been reported.
“No human implants of regenerative electrodes have been reported.”
The paper relies on this without support.
Cuff electrodes are the type of peripheral nervous system interface electrode most investigated in basic and applied research.
“Cuff electrodes are the type of PNS interface electrode most investigated in basic and applied research.”
The paper relies on this without support.
The neuromuscular system has non-linear and time-variant characteristics.
“the non-linear and time-variant characteristics of the neuromuscular system”
The paper relies on this without support.
A traumatic lesion of a peripheral nerve leads to Wallerian degeneration of the distal nerve.
“A traumatic lesion of a peripheral nerve leads to Wallerian degeneration of the distal nerve”
The paper relies on this without support.
Healing of a peripheral nerve lesion occurs only under favorable conditions involving sprouting of axons from the proximal stump, outgrowth along the distal stump, and reinnervation of target tissues.
“healing of such a lesion occurs only under favorable conditions involving sprouting of axons from the proximal nerve stump, outgrowth along the distal nerve stump, and reinnervation of target tissues”
The paper relies on this without support.
Recovery from a peripheral nerve lesion is usually delayed and limited if the lesion site is very proximal.
“Recovery is usually delayed and limited if the lesion site is very proximal.”
The paper relies on this without support.
Muscle atrophy prevents formation of new neuromuscular junctions at a later time when regenerating nerve fibers may reach the muscle.
“muscle atrophy prevents the formation of new neuromuscular junctions at a later time point when regenerating nerve fibers may reach the muscle”
The paper relies on this without support.
Regenerated nerve fibers have smaller than normal diameter and internodal length.
“the smaller than normal diameter and internodal length of regenerated fibers”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although more challenging to carry out compared to nerve stimulation due to the distance between electrodes and the weak electrical signals transmitted by axons, with an ECM-rich epineurium separating the two, motor and sensory nerve signals gathered using cuff electrodes have been used to guide and fine-tune prostheses such as artificial limbs in human patients (Micera et al., 2001; Navarro et al”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Navarro et al., 2005
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For nerve stimulation at the clinical level, epineurial cuffs remain the preferred choice (Navarro et al., 2005).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Navarro et al., 2005
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A thickening of the epineurium as part of FBR can dissipate the already weak electrical signals transmitted by axons, limiting the use of these devices for electrical recording applications in long-term implantations (Navarro et al., 2005).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Navarro et al., 2005
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Based on the degree of invasiveness nerve neuroprosthetic designs can be categorized into three different groups (summarized in Figures 4, 5).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Navarro et al., 2005
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Most commonly this is in the form of a full nerve transection, where the two ends of the nerve are cleanly separated and a gap forms between the two (Navarro et al., 2005; Thompson et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Navarro et al., 2005
Experimental — accuracy not yet measured
The cited source says what the claim attributes to it.
In the citing paper
“However, current peripheral nerve interfaces have limitations, which minimize their clinical utility (1, 2).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“Many electrodes have been developed for peripheral nerves (Warren et al., 2016) and a comparison of their performance been conducted more than a decade ago (Navarro et al., 2005), but an extensive, quantitative comparison (on e.g., longevity and spatial resolution) of their use in neuroprostheses in recent literature is absent.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Navarro et al., 2005
The cited source says what the claim attributes to it.
In the citing paper
“However, clinical practice of peripheral nerve stimulation for the control of neuroprosthesis is limited (Navarro et al., 2005).”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Navarro et al., 2005
The cited source says what the claim attributes to it.
In the citing paper
“But even with this definition, it is hard to compare the electrodes due to the difference in impedance, spatial resolution (Navarro et al., 2005) and inconsistent SNR results across studies published so far.”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Navarro et al., 2005
The cited source says what the claim attributes to it.
In the citing paper
“It can also be used to record signals from nerves for the intent of neuroprosthetic control; however the fact that the measurements are done in a magnetically shielded room restricts its use [12].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [12]
The cited source says what the claim attributes to it.
In the citing paper
“Data collected by Navarro et al. point to the fact that currently in clinical practice, implanted electrodes are generally extraneural [36].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [36]
The cited source says what the claim attributes to it.
In the citing paper
“The electrode's degree of invasiveness is an important factor in the neural response [5].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [5]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“However, the information on specifically interfacing the PNS to control these advanced prostheses is more sparse.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [12]
Experimental — accuracy not yet measuredIn the citing paper
“State-of-the-art implants that target the PNS are, therefore, mainly based on flexible materials (Navarro et al. 2005).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Navarro et al. 2005
Citations
Cites
The Handbook of brain theory and neural networks
(1996) · Choice Reviews Online · doi:10.5860/choice.33-4484 · Cited by 3,913
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 2,980
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,605
(1991) · Medical Entomology and Zoology · Cited by 1,512
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 720
Nicolelis, M. A. L. (2001) · Nature · doi:10.1038/35053191 · Cited by 705
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationKuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., Loeb, G. E., Berwald‐Netter, Y., & Okun, L. M. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 572
Self-citationA Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T. R., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 570
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlögl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Ochoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467 · cited 2×
“Microstimulation through the electrode can be used to activate single axons, although in most cases stimulation affects small groups of axons in the fascicle (Ochoa and Torebjörk, 1983; Torebjörk et al., 1987).”
BackgroundA myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Wilkinson, D. W. (1987) · doi:10.1242/dev.99.3.439 · Cited by 418
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 411
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 3×
“A design variation of the cuff electrode is the flatinterface nerve electrode (FINE) developed by Durand and coworkers (Tyler and Durand, 2002).”
BackgroundMethodIn vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364
Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7273 · Cited by 364
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 6×
“…of selectively recording single-unit responses from mechanoreceptors, although only in 10–20% of the electrodes, and evoked graded recruitment of force in muscle groups in a highly selective fashion with current injections in the 1–20 mA range (Branner and Norman, 2000; Branner et al., 2001).”
BackgroundInfluentialSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“Recently, LIFE electrodes have been used to control a hand prosthesis using the ENG signals recorded from peripheral nerves of amputee subjects (Dhillon et al., 2004).”
MethodMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Self-citationSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Neural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
A high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 303
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301
Wilkinson, D. G., Bailes, J. A., Champion, J. E., & McMahon, A. P. (1987) · Development · doi:10.1242/dev.99.4.493 · Cited by 293
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275
Long-term results of peripheral nerve stimulation for reflex sympathetic dystrophy
Hassenbusch, S. J., Stanton-Hicks, M., Schoppa, D., Walsh, J. G., & Covington, E. C. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.3.0415 · Cited by 254 · cited 1×
“The latter application is of limited benefit because it should be applied only when pain involves one nerve territory in the head or the limbs and has frequent morbidity associated with electrode approximation, electrode displacement, and lead failure (Hassenbusch et al., 1996).”
BackgroundBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
New Trends in Neuromodulation for the Management of Neuropathic Pain
Aló, K., & Holsheimer, J. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00003 · Cited by 241
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240
The application of neural networks to myoelectric signal analysis: a preliminary study
Kelly, M. F., Parker, P. A., & Scott, R. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52324 · Cited by 237
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T. J., Mabuchi, K., & Fujita, H. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 221
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216
The effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Acoustic myography: A noninvasive monitor of motor unit fatigue
Barry, D. T., Geiringer, S. R., & Ball, R. D. (1985) · Muscle & Nerve · doi:10.1002/mus.880080303 · Cited by 208
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Self-citationThe application of implant technology for cybernetic systems
Warwick, K., Gasson, M., Hutt, B., Goodhew, I., Kyberd, P., Andrews, B., Teddy, P., & Shad, A. (2003) · Archives of Neurology · doi:10.1001/archneur.60.10.1369 · Cited by 206
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 1×
“From the first works by Graupe and colleagues (Graupe and Cline, 1975; 1982; Graupe et al., 1982), the EMG signal was modeled as the amplitude-modulated Gaussian noise whose variance is related to the force developed by the muscle.”
BackgroundBrummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192 · cited 2×
“However, the use of EMG for this purpose under dynamic conditions (as in the case of exoskeleton control) presents several problems because of muscle dynamics and possible prostheses (Rainoldi et al., 2000).”
BackgroundJimbo, Y., Robinson, H. P. C., & Kawana, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238465 · Cited by 192 · cited 1×
“Having surface topologies on the substrate, axonal outgrowth of embryonic nerve cells from rats was observed and electrical activity was recorded in a microstructure with 16 electrodes that were connected with grooves (Jimbo and Kawana, 1992; Jimbo et al., 1993).”
MethodAn exoskeletal robot for human shoulder joint motion assist
Kiguchi, K., Iwami, K., Yasuda, M., Watanabe, K., & Fukuda, T. (2003) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2003.809168 · Cited by 191
Rattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Unsupervised pattern recognition for the classification of EMG signals
Christodoulou, C. I., & Pattichis, C. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740879 · Cited by 186
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
INTRANEURAL MICROSTIMULATION IN MAN: ITS RELATION TO SPECIFICITY OF TACTILE SENSATIONS
TOREBJÖRK, H. E., VALLBO, Å. B., & OCHOA, J. L. (1987) · Brain · doi:10.1093/brain/110.6.1509 · Cited by 184
Long-term pain control by direct peripheral-nerve stimulation.
Nashold, B. S., Goldner, J. L., Mullen, J. B., & Bright, D. S. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00001 · Cited by 184 · cited 2×
“, 1997), for reducing pain (Nashold et al., 1982; Strege et al., 1994; StantonHicks and Salamon, 1997), for phrenic nerve pacing for ventilatory assistance (Glenn et al.”
BackgroundLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Self-citationEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
The Biomedical Engineering Handbook
von Maltzahn, W. W. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.sec8 · Cited by 172
Fisher, R. S., & Handforth, A. (1999) · Neurology · doi:10.1212/wnl.53.4.666 · Cited by 169
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 168 · cited 2×
“Regenerative electrodes are designed to interface a high number of nerve fibers by using an array of holes, with electrodes built around them, implanted between the severed stumps of a peripheral nerve (Llinás et al., 1973; Edell, 1986; Kovacs et al., 1992; Dario et al., 1998).”
BackgroundNeural prostheses: Replacing motor function after disease or disability
Hilton‐Jones, D. (1993) · Neuromuscular Disorders · doi:10.1016/0960-8966(93)90069-v · Cited by 164
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160
Sensory nerve recording for closed‐loop control to restore motor functions
Popovic, D. B., Stein, R. B., Jovanovic, K. L., Dai, R., Kostov, A., & Armstrong, W. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.247801 · Cited by 159
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 4×
“…for ventilatory assistance (Glenn et al., 1986; Creasey et al., 1996; Chervin and Guilleminault, 1997), for activation of lower extremity motion (Waters et al., 1985; Popovic, 1992; Haugland and Sinkjaer, 1995; Triolo et al., 1996; Graupe and Kohn, 1997; Popovic et al., 1998; Taylor et al.,…”
BackgroundInfluentialKobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Kennedy, P. R. (1989) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(89)90142-8 · Cited by 151
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · cited 1×
“Electrodes that moderately flattened the nerve demonstrated the best selectivity for limb motion measurements, which were maintained throughout the implant time (Tyler and Durand, 2003; Leventhal and Durand, 2004).”
BackgroundA micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144
(1986) · PubMed · Cited by 137
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Recruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
Neural Networks: Concepts, Applications, and Implementations
Antognetti, P., & Milutinović, V. M. (1991) · Medical Entomology and Zoology · Cited by 132
Three-dimensional microfabrication using synchrotron radiation
Ehrfeld, W., & Münchmeyer, D. (1991) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90289-3 · Cited by 127
Electrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126 · cited 1×
“Having surface topologies on the substrate, axonal outgrowth of embryonic nerve cells from rats was observed and electrical activity was recorded in a microstructure with 16 electrodes that were connected with grooves (Jimbo and Kawana, 1992; Jimbo et al., 1993).”
MethodImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125
Self-citationA method to effect physiological recruitment order in electrically activated muscle
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76384 · Cited by 125
Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes
Haugland, M. K., Hoffer, J. A., & Sinkjær, T. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.296346 · Cited by 125
Twenty Years of Experience in Phrenic Nerve Stimulation to Pace the Diaphragm
GLENN, W. W. L., PHELPS, M. L., ELEFTERLEADES, J. A., DENTZ, B., & HOGAN, J. F. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06627.x · Cited by 125
Intramuscular electrical stimulation: Tissue damage
Mortimer, J. T., Kaufman, D., & Roessmann, U. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02364479 · Cited by 123
Neural Prostheses for Restoration of Sensory and Motor Function
Chapin, J. K., & Moxon, K. A. (2000) · CRC Press eBooks · doi:10.1201/9781420039054 · Cited by 122
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Applications of cortical signals to neuroprosthetic control: a critical review
Lauer, R. T., Peckham, P. H., Kilgore, K. L., & Heetderks, W. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847817 · Cited by 120
Stimulation of the Central and Peripheral Nervous System for the Control of Pain
Stanton-Hicks, M., & Salamon, J. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199701000-00004 · Cited by 115
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110
Biopotentials as command and feedback signals in functional electrical stimulation systems
Sinkjær, T., Haugland, M. K., Inmann, A., Hansen, M., & Nielsen, K. D. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00178-9 · Cited by 110
Droge, M., Gross, G., Hightower, M., & Czisny, L. (1986) · The Journal of Neuroscience · doi:10.1523/jneurosci.06-06-01583.1986 · Cited by 109 · cited 1×
“The activity of embryonic spinal cord cells of mice has been recorded simultaneously over a period of several months on a planar glass substrate with 64 iridium tin oxide electrodes (Droge et al., 1986).”
MethodA slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108 · cited 1×
“Histological cross-sections showed that the SPINE rearranges the epineurium and penetrates deep within a multifascicular nerve but did not disrupt the perineurium (Tyler and Durand, 1997).”
BackgroundAn intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
(1998) · PubMed · Cited by 107
Self-citationLawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · cited 1×
“The use of multistrand Kevlar LIFEs (m-polyLIFE) increases the tensile strength and signal-to-noise ratio (Lawrence et al., 2004).”
MethodOnishi, H., Yagi, R., Akasaka, K., Momose, K., Ihashi, K., & Handa, Y. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00020-6 · Cited by 105
Time-scale analysis of motor unit action potentials
Pattichis, C. S., & Pattichis, M. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.797992 · Cited by 105
A 64-site multishank CMOS low-profile neural stimulating probe
Kim, C., & Wise, K. D. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535406 · Cited by 103
Grill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103
The relationship between electromyogram and muscle force
Hof, A. L. (1997) · Sportverletzung · Sportschaden · doi:10.1055/s-2007-993372 · Cited by 103 · cited 1×
“This approach is supported by biomechanical studies (Hof, 1997; Onishi et al., 2000) showing that under isometric contractions the relationship between force and EMG can be considered linear.”
Jezernik, S., Craggs, M., Grill, W. M., Creasey, G., & Rijkhoff, N. J. M. (2002) · Neurological Research · doi:10.1179/016164102101200294 · Cited by 102
Triolo, R. J., Bieri, C., Uhlir, J., Kobetic, R., Scheiner, A., & Marsolais, E. B. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90133-1 · Cited by 102
Procházka, A., Mushahwar, V. K., & McCreery, D. B. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0099b.x · Cited by 101
Kern, H., Hofer, C., Mödlin, M., Forstner, C., Raschka‐Högler, D., Mayr, W., & Stöhr, H. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06933.x · Cited by 100
Hewson, D. J., Hogrel, J.-Y., Langeron, Y., & Duchêne, J. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00097-4 · Cited by 99 · cited 1×
“The impedance at the electrode–skin interface is largely variable between individuals at low frequencies, whereas at high frequencies the decline of impedance values with time depends on the electrode type (Hewson et al., 2003).”
BackgroundRiso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Development of percutaneous intramuscular electrode for multichannel FES system
Handa, Y., Hoshimiya, N., Iguchi, Y., et al. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32102 · Cited by 98
Larsen, J. O., Thomsen, M., Haugland, M., & Sinkjær, T. (1998) · Acta Neuropathologica · doi:10.1007/s004010050907 · Cited by 96
Improving detection of muscle activation intervals
Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982274 · Cited by 95
Self-citationAn algorithm for detecting the onset of muscle contraction by EMG signal processing
Micera, S., Sabatini, A. M., & Dario, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00017-4 · Cited by 95
Self-citationMuscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Plasma‐deposited passivation layers for moisture and water protection
Vogt, M., & Hauptmann, R. (1995) · Surface and Coatings Technology · doi:10.1016/0257-8972(95)08268-9 · Cited by 92 · cited 1×
“Better stability was achieved with multilayers (Cogan et al., 1993; Vogt and Hauptmann, 1995).”
Implanted stimulators for restoration of function in spinal cord injury
Bhadra, N., Kilgore, K. L., & Peckham, P. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00012-1 · Cited by 92
Micera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Self-citationJanders, M., Egert, U., Stelzle, M., & Nisch, W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656936 · Cited by 90
Vagus nerve stimulation for intractable epilepsy: a review
McLachlan, R. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00002 · Cited by 89
Sparto, P. J., Parnianpour, M., Barría, E. A., et al. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867887 · Cited by 86
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis
Kilgore, K. L., Peckham, P. H., Keith, M. W., Montague, F. W., Hart, R. L., Gazdik, M. M., Bryden, A. M., Snyder, S. A., & Stage, T. G. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.11.0457 · Cited by 85
Mannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85
Subfascicle stimulation selectivity with the flat interface nerve electrode
Leventhal, D. K., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569266 · Cited by 81
Electrical stimulation of sacral roots for micturition after spinal cord injury
Creasey, G. H. (1993) · Urologic Clinics of North America · doi:10.1016/s0094-0143(21)00511-5 · Cited by 80
Worldwide experience with the Finetech‐Brindley sacral anterior root stimulator
Van Kerrebroeck, P. E. V., Koldewijn, E. L., & Debruyne, F. M. J. (1993) · Neurourology and Urodynamics · doi:10.1002/nau.1930120511 · Cited by 80
Haugland, M. K., & Hoffer, J. A. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.296345 · Cited by 79
(1996) · PubMed · Cited by 79
Stieglitz, T., Ruf, H. H., Gross, M., Schüettler, M., & Meyer, J.-U. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00019-2 · Cited by 78
Self-citationCharacterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes
Yoshida, K., & Stein, R. B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740885 · Cited by 76
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
Metallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74
Chae, J., & Hart, R. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199811000-00013 · Cited by 72
Satisfaction with and usage of a hand neuroprosthesis
Wuolle, K. S., Van Doren, C. L., Bryden, A. M., Hunter Peckham, P., Keith, M. W., Kilgore, K. L., & Grill, J. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90123-5 · Cited by 70
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69
Retina implant—a bioMEMS challenge
Meyer, J.-U. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00807-x · Cited by 69
(1998) · Library and Archives Canada (Government of Canada) · Cited by 68
Aoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 67
Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives
Rijkhoff, N. J. M. (2004) · Child's Nervous System · doi:10.1007/s00381-003-0859-1 · Cited by 66
First clinical experience with BION implants for therapeutic electrical stimulation
Salter, A.-C. D., Bagg, S. D., Creasy, J. L., Romano, C., Romano, D., Richmond, F. J. R., & Loeb, G. E. (2004) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2004.04005.x · Cited by 66
Krarup, C., Loeb, G. E., & Pezeshkpour, G. H. (1988) · Muscle & Nerve · doi:10.1002/mus.880110906 · Cited by 66
Stieglitz, T., & Gross, M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)01021-8 · Cited by 65
Self-citationControl of neural prostheses for grasping and reaching
Popović, M. B. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00187-x · Cited by 64
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64
Self-citationThe frequency response of frog muscle spindles under various conditions
Kirkwood, P. A. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009791 · Cited by 63
González, C., & Rodrı́guez, M. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)02202-9 · Cited by 63
Information contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63
Extradural implantation of sacral anterior root stimulators.
Sauerwein, D., Ingunza, W., Fischer, J., Madersbacher, H., Polkey, C. E., Brindley, G. S., Colombel, P., & Teddy, P. (1990) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.8.681 · Cited by 62
Multielectrode intrafascicular and extraneural stimulation
Veltink, P. H., van Alsté, J. A., & Boom, H. B. K. (1989) · Medical and Biological Engineering and Computing · doi:10.1007/bf02442165 · Cited by 62
Muscle fatigue measured with evoked muscle vibrations
Barry, D. T., Hill, T., & Im, D. (1992) · Muscle & Nerve · doi:10.1002/mus.880150308 · Cited by 62 · cited 1×
“Acoustic signals increase in parallel with surface EMG signals during voluntary and evoked contraction, but acoustic amplitude decays with fatigue whereas EMG amplitude does not (Barry et al., 1985; 1992) .”
BackgroundCeballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61
Self-citationEmptying the bladder by stimulating sacral ventral roots.
Gs, B. (1974) · PubMed · Cited by 61
Selective Detrusor Activation By Electrical Sacral Nerve Root Stimulation in Spinal Cord Injury
Rijkhoff, N., Wijkstra, H., Kerrebroeck, P. V., & Debruyne, F. M. J. (1997) · The Journal of Urology · doi:10.1016/s0022-5347(01)65032-8 · Cited by 60
Chronic peripheral nerve pain treated with direct electrical nerve stimulation
Strege, D. W., Cooney, W. P., Wood, M. B., Johnson, S. J., & Metcalf, B. J. (1994) · The Journal of Hand Surgery · doi:10.1016/0363-5023(94)90092-2 · Cited by 60
Embryonic Cord Transplants in Peripheral Nerve Restore Skeletal Muscle Function
Thomas, C. K., Erb, D. E., Grumbles, R. M., & Bunge, R. P. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.591 · Cited by 60
Neural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58
Self-citationMicera, S., Jensen, W., Sepulveda, F., Riso, R. R., & Sinkjaer, T. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930903 · Cited by 58
Diaphragm Pacing for Respiratory Insufficiency
Chervin, R. D., & Guilleminault, C. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00003 · Cited by 56
Rupp, R., & Gerner, H. J. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_55 · Cited by 56
Arrays for chronic functional microstimulation of the lumbosacral spinal cord
McCreery, D. B., Pikov, V., Lossinsky, A. S., Bullara, L. A., & Agnew, W. F. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827223 · Cited by 55
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55
Modeling study of peripheral nerve recording selectivity
Perez-Perive, J., & Durund, D. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867874 · Cited by 55
Negredo, P., Castro, J. E., Lago, N., Navarro, X., & Avendaño, C. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.07.017 · Cited by 55
Self-citationChronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55
Separation of action potentials in multiunit intrafascicular recordings
Goodall, E. V., & Horch, K. W. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.125014 · Cited by 53
Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
Cameron, T., Liinamaa, T. L., Loeb, G. E., & Richmond, F. J. R. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704871 · Cited by 53
(2001) · PubMed · Cited by 52
Self-citationMotor prosthesis for restoration of upper extremity function
Peckham, P. H. (1992) · Medical Entomology and Zoology · Cited by 51
EMG prosthetic hand controller discriminating ten motions using real-time learning method
Nishikawa, D., Yu, W., Yokoi, H., & Kakazu, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1999.811706 · Cited by 50
Malmstrom, J. A., McNaughton, T. G., & Horch, K. W. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.35 · Cited by 50 · cited 1×
“Activity arising from cutaneous receptors in response to stimuli has been recorded in several studies, although activity was found to be small and difficult to distinguish from the background noise in the recording (Malmstrom et al., 1998; Yoshida et al., 2000).”
Background(2000) · PubMed · Cited by 50
Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
Yoshida, K., Jovanović, K., & Stein, R. B. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00176-4 · Cited by 49
Wallman, L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00342-2 · Cited by 49
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46
Peripheral nerve regeneration through microelectrode arrays based on silicon technology
Navarro, X., Calvet, S., Butí, M., Gómez, N., Cabruja, E., Garrido, P., Villa, R., & Valderrama, E. (1996) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-1996-9303 · Cited by 46
Self-citationBien, Z. N. (2000) · Cited by 45
Cavallaro, E., Micera, S., Dario, P., Jensen, W., & Sinkjaer, T. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816075 · Cited by 44 · cited 2×
“Recorded ENG signals using cuff electrodes allowed the prediction of ankle movements in an animal model (Micera et al., 2001a; Jensen et al., 2002; Cavallaro et al., 2003) with the idea of using this information for the closed-loop control of standing in paraplegic subjects.”
BackgroundMethodSelf-citationFunctional electrical stimulation using microstimulators to correct foot drop: a case study
Weber, D. J., Stein, R. B., Chan, K. M., Loeb, G. E., Richmond, F. J. R., Rolf, R., James, K., Chong, S. L., Thompson, A. K., & Misiaszek, J. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-078 · Cited by 44
Rutten, W. L. C., Frieswijk, T. A., Smit, J. P. A., Rozijn, T. H., & Meier, J. H. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96802-6 · Cited by 43
Guided outgrowth of leech neurons in culture
Fromherz, P., Schaden, H., & Vetter, T. (1991) · Neuroscience Letters · doi:10.1016/0304-3940(91)90724-8 · Cited by 43
(1972) · PubMed · Cited by 43
Flagged first, then by citations
Research works printed but not linked: 18
- Brindley GS, 1995, Neuroprostheses., 15
- Bronzino JD, 1995, Biomedical Engineering Handbook.
- CoganSF LiuY‐P McCaffreyM TwardochUM(1993). Thin film hermetic coatings. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 5 N44‐NS‐2‐2311.
- De Luca CJ, 2002, Surface Electromyography: Detection and Recording.
- EdellDJ DevaneyL DurfeeWK GleasonEF GleasonKK HerndonTO ThompsonCV WrightonMS(1993). Bioresistant integrated circuits. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 9 NO1‐NS‐0‐2399.
- Hoffer JA, 2001, Neural Prostheses for Restoration of Sensory and Motor Function., 139
- Llinás R, 1973, Brain Unit Activity During Behaviour., 105
- Naples GG, 1990, Neural Prostheses: Fundamental Studies, Biophysics and Bioengineering Series., 107
- Nishikawa D, 1999, IEEE IROS'99, Kyongju, 1592
- PineJ TaiY‐C BuzsakiG BraginA CarpiD(1994). The cultured neuron probe. Quarterly Progress Report NIH‐NINDS Neural Prosthesis Program No. 4 NO1‐NS‐3‐2393.
- Popovic DB, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability., 233
- Roblee LS, 1990, Neural Prostheses: Fundamental Studies, Biophysics and Bioengineering Series., 26
- Santa‐Cruz MC, 2000, IFESS 2000, 436
- SinghJ PeckRA LoebGE(2001). Development of BIONs technology for functional electrical stimulation: hermetic packaging. Proceedings of the 23th Annual International Conference of IEEE Eng Med and Bio Soc.
- Stein RB, 1992, Neural Prostheses. Replacing Motor Function After Diseases or Disability
- StieglitzT HabererW KammerS SchanzeT(2003). A simple model to investigate the stability of flexible micromachined retina stimulators. Proceedings of the 8th Annual International Conference of the International Functional Electrical Stimulation Society pp69–73.
- Tatic‐LucicS TaiY‐C WrightJA PineJ DenisonT(1993). Silicon‐micromachined neurochips for in vitro studies of cultured neural networks. Proceedings of the International Conference on Solid State Sensors and Actuators pp943–946.
- Tyler DJ, 1994, Interfascicular electrical stimulation for selectively activating axons, IEEE–EMBS Mag, 13, 575
Cited by
Sorted by citations
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
“37 Navarro, X. et al. (2005) A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and”
BackgroundRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
“In parallel, the rapid development of neural interfaces for the peripheral nervous system (16) has provided potential for new tools through which bidirectional communication with nerves in the stump could be potentially restored.”
BackgroundSelf-citationSurface Electromyography Signal Processing and Classification Techniques
Chowdhury, R. H., Reaz, M. B. I., Ali, M. H., Bakar, A. A. A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,013
“For this reason, they are widely used as surface electrodes [7].”
MethodFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 999
A comprehensive review on emerging artificial neuromorphic devices
Zhu, J., Zhang, T., Yang, Y., & Huang, R. (2020) · Applied Physics Reviews · doi:10.1063/1.5118217 · Cited by 783
Metadata
- Authors
- Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P.
- Affiliations
- Universitat Autònoma de Barcelona (ES)
- University of Freiburg (DE)
- Scuola Superiore Sant'Anna (IT)
- Corresponding author
- Navarro, Xavier
- Venue
- Journal of the Peripheral Nervous System
- Publisher
- Wiley
- Published
- 2005-09
- Volume
- 10
- Issue
- 3
- Pages
- 229-258
- ISSN
- 1085-9489 (ISSN-L)
- 1529-8027
- OpenAlex
- W2108068079
- Cited by
- 845
- References
- 259
- Citations by year
- 2026: 18 · 2025: 27 · 2024: 36 · 2023: 32 · 2022: 39 · 2021: 53 · 2020: 49 · 2019: 58 · 2018: 53 · 2017: 49 · 2016: 60 · 2015: 57 · 2014: 58 · 2013: 45 · 2012: 28
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of the Peripheral Nervous System (publishedVersion)
- PubMed (publishedVersion)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- European Commission (IST-001917)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- neural prostheses, peripheral nerve interfaces, peripheral nerve stimulation, neuromuscular stimulation, electromyography, surface electrodes, cuff electrodes, intrafascicular electrodes, electrode design, tissue damage, robotic prostheses
- MeSH terms
- Animals, Bionics, Electrodes, Electromyography, Humans, User-Computer Interface, Peripheral Nervous System, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review